5,000 kg
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
24.00 kW
24.00 kW
El input
5.59 kW
9.06 kW
COP
4.29
2.65
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
47 dB(A)
47 dB(A)
Sound power level outdoor
74 dB(A)
74 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
141 %
116 %
Prated
20.00 kW
18.00 kW
SCOP
3.60
2.98
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
17.40 kW
15.60 kW
COP Tj = -7°C
2.30
1.65
Pdh Tj = +2°C
10.77 kW
9.50 kW
COP Tj = +2°C
3.60
3.10
Pdh Tj = +7°C
8.70 kW
8.30 kW
COP Tj = +7°C
5.10
4.35
Pdh Tj = 12°C
8.70 kW
8.50 kW
COP Tj = 12°C
4.90
4.60
Pdh Tj = Tbiv
17.40 kW
15.60 kW
COP Tj = Tbiv
2.10
1.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
18.00 kW
14.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.30
1.45
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
55 °C
55 °C
Poff
36 W
36 W
PTO
0 W
0 W
PSB
36 W
36 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.70 kW
3.60 kW
Annual energy consumption Qhe
11410 kWh
12210 kWh
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
24.00 kW
24.00 kW
El input
5.59 kW
9.06 kW
COP
4.29
2.65
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
47 dB(A)
47 dB(A)
Sound power level outdoor
74 dB(A)
74 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
142 %
118 %
Prated
20.00 kW
18.00 kW
SCOP
3.60
2.98
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
17.40 kW
15.60 kW
COP Tj = -7°C
2.30
1.65
Pdh Tj = +2°C
10.77 kW
9.50 kW
COP Tj = +2°C
3.60
3.10
Pdh Tj = +7°C
8.70 kW
8.30 kW
COP Tj = +7°C
5.10
4.35
Pdh Tj = 12°C
8.70 kW
8.50 kW
COP Tj = 12°C
4.90
4.60
Pdh Tj = Tbiv
17.40 kW
15.60 kW
COP Tj = Tbiv
2.10
1.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
18.00 kW
14.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.30
1.45
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
55 °C
55 °C
Poff
36 W
36 W
PTO
0 W
0 W
PSB
36 W
36 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.70 kW
3.60 kW
Annual energy consumption Qhe
11278 kWh
12078 kWh