Certificate holders

Subtype

Thermia Calibra Eco 12

Certificate Holder
Thermia
Snickaregatan 1
Arvika
Sweden
Registration number
012-C700111 / Issue 1
Certification Body
RISE CERT
Subtype title
Thermia Calibra Eco 12
Driving energy
Electricity
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R452B
Mass of Refrigerant

1,300 kg

Certification Date
25.08.2021
Testing basis
EN 14511:2018, EN 14825:2018, EN 12102:2017
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

Thermia Calibra Eco 12 400V
Configure model
Model name
Thermia Calibra Eco 12 400V
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

5.21 kW

8.42 kW

El input

1.09 kW

2.84 kW

COP

4.78

2.96

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

222 %

164 %

Prated

11.52 kW

10.57 kW

SCOP

5.76

4.29

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.52 kW

10.57 kW

COP Tj = +2°C

4.39

2.96

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

7.41 kW

6.79 kW

COP Tj = +7°C

5.38

3.81

Cdh Tj = +7 °C

0.99

1.00

Pdh Tj = 12°C

3.29 kW

3.02 kW

COP Tj = 12°C

6.47

5.12

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2674 kWh

3290 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

226 %

168 %

Prated

11.52 kW

10.57 kW

SCOP

5.85

4.39

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.97 kW

6.40 kW

COP Tj = -7°C

5.69

4.02

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.24 kW

3.89 kW

COP Tj = +2°C

6.38

4.92

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

2.73 kW

2.50 kW

COP Tj = +7°C

5.79

4.88

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

2.78 kW

2.74 kW

COP Tj = 12°C

5.51

4.74

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4856 kWh

5928 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

219 %

162 %

Prated

11.52 kW

10.57 kW

SCOP

5.67

4.25

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.19 kW

9.35 kW

COP Tj = -7°C

4.66

3.23

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

6.20 kW

5.69 kW

COP Tj = +2°C

5.81

4.27

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.99 kW

3.66 kW

COP Tj = +7°C

6.39

5.06

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

2.77 kW

2.73 kW

COP Tj = 12°C

5.67

4.67

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4195 kWh

5134 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

12.24 kW

14.24 kW

El input

2.01 kW

3.84 kW

COP

6.08

3.71

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

295 %

214 %

Prated

12.24 kW

14.24 kW

SCOP

7.57

5.56

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.24 kW

14.24 kW

COP Tj = +2°C

6.08

3.71

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

7.87 kW

9.16 kW

COP Tj = +7°C

7.15

4.96

Cdh Tj = +7 °C

0.99

1.00

Pdh Tj = 12°C

3.50 kW

4.07 kW

COP Tj = 12°C

8.40

6.62

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2161 kWh

3425 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

300 %

223 %

Prated

12.24 kW

14.24 kW

SCOP

7.70

5.77

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.41 kW

8.62 kW

COP Tj = -7°C

7.43

5.28

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

4.51 kW

5.25 kW

COP Tj = +2°C

8.14

6.31

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

3.71 kW

3.37 kW

COP Tj = +7°C

8.35

7.00

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

3.68 kW

3.66 kW

COP Tj = 12°C

7.96

6.72

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3917 kWh

6086 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

292 %

213 %

Prated

12.24 kW

14.24 kW

SCOP

7.51

5.52

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.83 kW

12.60 kW

COP Tj = -7°C

6.35

4.09

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

6.59 kW

7.67 kW

COP Tj = +2°C

7.52

5.56

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.24 kW

4.93 kW

COP Tj = +7°C

8.40

6.49

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

3.70 kW

3.65 kW

COP Tj = 12°C

8.22

6.57

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3369 kWh

5331 kWh

Thermia Calibra Eco 12 Duo 400V
Configure model
Model name
Thermia Calibra Eco 12 Duo 400V
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

5.21 kW

8.42 kW

El input

1.09 kW

2.84 kW

COP

4.78

2.96

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

222 %

164 %

Prated

11.52 kW

10.57 kW

SCOP

5.76

4.29

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.52 kW

10.57 kW

COP Tj = +2°C

4.39

2.96

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

7.41 kW

6.79 kW

COP Tj = +7°C

5.38

3.81

Cdh Tj = +7 °C

0.99

1.00

Pdh Tj = 12°C

3.29 kW

3.02 kW

COP Tj = 12°C

6.47

5.12

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2674 kWh

3290 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

226 %

168 %

Prated

11.52 kW

10.57 kW

SCOP

5.85

4.39

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.97 kW

6.40 kW

COP Tj = -7°C

5.69

4.02

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.24 kW

3.89 kW

COP Tj = +2°C

6.38

4.92

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

2.73 kW

2.50 kW

COP Tj = +7°C

5.79

4.88

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

2.78 kW

2.74 kW

COP Tj = 12°C

5.51

4.74

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4856 kWh

5928 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

219 %

162 %

Prated

11.52 kW

10.57 kW

SCOP

5.67

4.25

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.19 kW

9.35 kW

COP Tj = -7°C

4.66

3.23

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

6.20 kW

5.69 kW

COP Tj = +2°C

5.81

4.27

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.99 kW

3.66 kW

COP Tj = +7°C

6.39

5.06

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

2.77 kW

2.73 kW

COP Tj = 12°C

5.67

4.67

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4195 kWh

5134 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

12.24 kW

14.24 kW

El input

2.01 kW

3.84 kW

COP

6.08

3.71

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

295 %

214 %

Prated

12.24 kW

14.24 kW

SCOP

7.57

5.56

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.24 kW

14.24 kW

COP Tj = +2°C

6.08

3.71

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

7.87 kW

9.16 kW

COP Tj = +7°C

7.15

4.96

Cdh Tj = +7 °C

0.99

1.00

Pdh Tj = 12°C

3.50 kW

4.07 kW

COP Tj = 12°C

8.40

6.62

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2161 kWh

3425 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

300 %

223 %

Prated

12.24 kW

14.24 kW

SCOP

7.70

5.77

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.41 kW

8.62 kW

COP Tj = -7°C

7.43

5.28

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

4.51 kW

5.25 kW

COP Tj = +2°C

8.14

6.31

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

3.71 kW

3.37 kW

COP Tj = +7°C

8.35

7.00

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

3.68 kW

3.66 kW

COP Tj = 12°C

7.96

6.72

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3917 kWh

6086 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

292 %

213 %

Prated

12.24 kW

14.24 kW

SCOP

7.51

5.52

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.83 kW

12.60 kW

COP Tj = -7°C

6.35

4.09

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

6.59 kW

7.67 kW

COP Tj = +2°C

7.52

5.56

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.24 kW

4.93 kW

COP Tj = +7°C

8.40

6.49

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

3.70 kW

3.65 kW

COP Tj = 12°C

8.22

6.57

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3369 kWh

5331 kWh

Thermia Calibra Eco 12 230V
Configure model
Model name
Thermia Calibra Eco 12 230V
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

5.21 kW

8.42 kW

El input

1.09 kW

2.84 kW

COP

4.78

2.96

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

222 %

164 %

Prated

11.52 kW

10.57 kW

SCOP

5.76

4.29

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.52 kW

10.57 kW

COP Tj = +2°C

4.39

2.96

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

7.41 kW

6.79 kW

COP Tj = +7°C

5.38

3.81

Cdh Tj = +7 °C

0.99

1.00

Pdh Tj = 12°C

3.29 kW

3.02 kW

COP Tj = 12°C

6.47

5.12

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2674 kWh

3290 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

226 %

168 %

Prated

11.52 kW

10.57 kW

SCOP

5.85

4.39

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.97 kW

6.40 kW

COP Tj = -7°C

5.69

4.02

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.24 kW

3.89 kW

COP Tj = +2°C

6.38

4.92

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

2.73 kW

2.50 kW

COP Tj = +7°C

5.79

4.88

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

2.78 kW

2.74 kW

COP Tj = 12°C

5.51

4.74

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4856 kWh

5928 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

219 %

162 %

Prated

11.52 kW

10.57 kW

SCOP

5.67

4.25

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.19 kW

9.35 kW

COP Tj = -7°C

4.66

3.23

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

6.20 kW

5.69 kW

COP Tj = +2°C

5.81

4.27

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.99 kW

3.66 kW

COP Tj = +7°C

6.39

5.06

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

2.77 kW

2.73 kW

COP Tj = 12°C

5.67

4.67

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4195 kWh

5134 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

12.24 kW

14.24 kW

El input

2.01 kW

3.84 kW

COP

6.08

3.71

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

295 %

214 %

Prated

12.24 kW

14.24 kW

SCOP

7.57

5.56

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.24 kW

14.24 kW

COP Tj = +2°C

6.08

3.71

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

7.87 kW

9.16 kW

COP Tj = +7°C

7.15

4.96

Cdh Tj = +7 °C

0.99

1.00

Pdh Tj = 12°C

3.50 kW

4.07 kW

COP Tj = 12°C

8.40

6.62

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2161 kWh

3425 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

300 %

223 %

Prated

12.24 kW

14.24 kW

SCOP

7.70

5.77

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.41 kW

8.62 kW

COP Tj = -7°C

7.43

5.28

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

4.51 kW

5.25 kW

COP Tj = +2°C

8.14

6.31

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

3.71 kW

3.37 kW

COP Tj = +7°C

8.35

7.00

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

3.68 kW

3.66 kW

COP Tj = 12°C

7.96

6.72

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3917 kWh

6086 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

292 %

213 %

Prated

12.24 kW

14.24 kW

SCOP

7.51

5.52

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.83 kW

12.60 kW

COP Tj = -7°C

6.35

4.09

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

6.59 kW

7.67 kW

COP Tj = +2°C

7.52

5.56

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.24 kW

4.93 kW

COP Tj = +7°C

8.40

6.49

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

3.70 kW

3.65 kW

COP Tj = 12°C

8.22

6.57

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3369 kWh

5331 kWh

Thermia Calibra Eco 12 Duo 230V
Configure model
Model name
Thermia Calibra Eco 12 Duo 230V
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

5.21 kW

8.42 kW

El input

1.09 kW

2.84 kW

COP

4.78

2.96

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

222 %

164 %

Prated

11.52 kW

10.57 kW

SCOP

5.76

4.29

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.52 kW

10.57 kW

COP Tj = +2°C

4.39

2.96

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

7.41 kW

6.79 kW

COP Tj = +7°C

5.38

3.81

Cdh Tj = +7 °C

0.99

1.00

Pdh Tj = 12°C

3.29 kW

3.02 kW

COP Tj = 12°C

6.47

5.12

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2674 kWh

3290 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

226 %

168 %

Prated

11.52 kW

10.57 kW

SCOP

5.85

4.39

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.97 kW

6.40 kW

COP Tj = -7°C

5.69

4.02

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.24 kW

3.89 kW

COP Tj = +2°C

6.38

4.92

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

2.73 kW

2.50 kW

COP Tj = +7°C

5.79

4.88

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

2.78 kW

2.74 kW

COP Tj = 12°C

5.51

4.74

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4856 kWh

5928 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

219 %

162 %

Prated

11.52 kW

10.57 kW

SCOP

5.67

4.25

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.19 kW

9.35 kW

COP Tj = -7°C

4.66

3.23

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

6.20 kW

5.69 kW

COP Tj = +2°C

5.81

4.27

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.99 kW

3.66 kW

COP Tj = +7°C

6.39

5.06

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

2.77 kW

2.73 kW

COP Tj = 12°C

5.67

4.67

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4195 kWh

5134 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

12.24 kW

14.24 kW

El input

2.01 kW

3.84 kW

COP

6.08

3.71

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

295 %

214 %

Prated

12.24 kW

14.24 kW

SCOP

7.57

5.56

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.24 kW

14.24 kW

COP Tj = +2°C

6.08

3.71

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

7.87 kW

9.16 kW

COP Tj = +7°C

7.15

4.96

Cdh Tj = +7 °C

0.99

1.00

Pdh Tj = 12°C

3.50 kW

4.07 kW

COP Tj = 12°C

8.40

6.62

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2161 kWh

3425 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

300 %

223 %

Prated

12.24 kW

14.24 kW

SCOP

7.70

5.77

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.41 kW

8.62 kW

COP Tj = -7°C

7.43

5.28

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

4.51 kW

5.25 kW

COP Tj = +2°C

8.14

6.31

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

3.71 kW

3.37 kW

COP Tj = +7°C

8.35

7.00

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

3.68 kW

3.66 kW

COP Tj = 12°C

7.96

6.72

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3917 kWh

6086 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

292 %

213 %

Prated

12.24 kW

14.24 kW

SCOP

7.51

5.52

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.83 kW

12.60 kW

COP Tj = -7°C

6.35

4.09

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

6.59 kW

7.67 kW

COP Tj = +2°C

7.52

5.56

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.24 kW

4.93 kW

COP Tj = +7°C

8.40

6.49

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

3.70 kW

3.65 kW

COP Tj = 12°C

8.22

6.57

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3369 kWh

5331 kWh