BoxAir Inverter BA37IS-1

Certificate Holder
Master Therm tepelna cerpadla s.r.o.
Vaclavske namesti 819/43
110 00 Praha
Czech Republic
Registration number
037-0070-21 / rev.1
Certification Body
SZU - Strojirensky zkusebni ustav (Engineering Test Institute, Public Enterprise)
Subtype title
BoxAir Inverter BA37IS-1
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

4,500 kg

Certification Date
26.01.2021
Testing basis
HP Keymark scheme rules rev. no. 7
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

BoxAir Inverter BA37IS-1
Configure model
Model name
BoxAir Inverter BA37IS-1
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.46 kW

10.34 kW

El input

2.43 kW

3.37 kW

COP

4.71

3.07

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

48 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

137 %

Prated

10.93 kW

10.02 kW

SCOP

4.49

3.51

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.67 kW

8.86 kW

COP Tj = -7°C

2.64

2.00

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

6.10 kW

5.45 kW

COP Tj = +2°C

4.38

3.41

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

4.06 kW

3.48 kW

COP Tj = +7°C

6.19

4.94

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.75 kW

4.08 kW

COP Tj = 12°C

7.62

6.01

Cdh Tj = +12 °C

0.97

0.97

Pdh Tj = Tbiv

9.67 kW

8.86 kW

COP Tj = Tbiv

2.64

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.04 kW

8.22 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.48

1.85

WTOL

60 °C

60 °C

Poff

19 W

19 W

PTO

19 W

19 W

PSB

19 W

19 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.89 kW

1.80 kW

Annual energy consumption Qhe

5029 kWh

5905 kWh