6,900 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
19.83 kW
22.96 kW
El input
4.24 kW
7.40 kW
COP
4.68
3.10
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
135 %
Prated
22.57 kW
22.06 kW
SCOP
4.50
3.45
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
20.64 kW
20.77 kW
COP Tj = -7°C
2.64
2.04
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
12.68 kW
12.27 kW
COP Tj = +2°C
4.21
3.22
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
8.04 kW
7.81 kW
COP Tj = +7°C
6.61
5.06
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
9.26 kW
9.01 kW
COP Tj = 12°C
8.02
6.13
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
22.57 kW
22.06 kW
COP Tj = Tbiv
2.35
1.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
22.57 kW
22.06 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.35
1.55
WTOL
60 °C
60 °C
Poff
27 W
27 W
PTO
26 W
26 W
PSB
27 W
27 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
10350 kWh
13226 kWh