Certificate holders

Subtype

BoxAir Inverter BA22I

Certificate Holder
Master Therm tepelna cerpadla s.r.o.
Vaclavske namesti 819/43
110 00 Praha
Czech Republic
Registration number
037-0063-21 / rev.1
Certification Body
SZU - Strojirensky zkusebni ustav (Engineering Test Institute, Public Enterprise)
Subtype title
BoxAir Inverter BA22I
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,300 kg

Certification Date
26.01.2021
Testing basis
HP Keymark scheme rules rev. no. 7
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

BoxAir Inverter BA22I
Configure model
Model name
BoxAir Inverter BA22I
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.91 kW

4.52 kW

El input

1.01 kW

1.49 kW

COP

4.84

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

132 %

Prated

4.51 kW

4.21 kW

SCOP

4.51

3.38

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.99 kW

3.72 kW

COP Tj = -7°C

2.74

2.04

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

2.31 kW

2.16 kW

COP Tj = +2°C

4.31

3.19

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

1.68 kW

1.48 kW

COP Tj = +7°C

6.44

4.89

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

1.60 kW

1.51 kW

COP Tj = 12°C

7.80

5.93

Cdh Tj = +12 °C

0.91

0.93

Pdh Tj = Tbiv

3.99 kW

3.72 kW

COP Tj = Tbiv

2.73

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.68 kW

3.47 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

1.90

WTOL

60 °C

60 °C

Poff

19 W

19 W

PTO

19 W

19 W

PSB

19 W

19 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.83 kW

0.74 kW

Annual energy consumption Qhe

2068 kWh

2570 kWh