1,000 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.18 kW
3.81 kW
El input
0.90 kW
1.32 kW
COP
4.66
2.89
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
208 %
152 %
Prated
7.08 kW
5.91 kW
SCOP
5.39
4.01
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.39 kW
5.27 kW
COP Tj = -7°C
4.12
2.96
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
3.54 kW
3.37 kW
COP Tj = +2°C
5.51
4.02
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
2.45 kW
2.12 kW
COP Tj = +7°C
6.28
4.87
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
1.16 kW
1.07 kW
COP Tj = 12°C
6.37
5.02
Cdh Tj = +12 °C
0.90
0.94
Pdh Tj = Tbiv
7.08 kW
5.91 kW
COP Tj = Tbiv
4.00
2.67
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.08 kW
5.91 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.00
2.67
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2713 kWh
3051 kWh