1,500 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.00 kW
5.50 kW
El input
1.94 kW
2.04 kW
COP
4.65
2.70
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
126 %
Prated
6.00 kW
6.00 kW
SCOP
4.65
3.23
Tbiv
-10 °C
-7 °C
TOL
-15 °C
-15 °C
Pdh Tj = -7°C
5.30 kW
5.30 kW
COP Tj = -7°C
2.75
2.05
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
3.20 kW
3.20 kW
COP Tj = +2°C
4.50
3.10
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
2.30 kW
3.00 kW
COP Tj = +7°C
6.50
4.50
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
2.80 kW
3.60 kW
COP Tj = 12°C
9.00
6.80
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
6.00 kW
5.30 kW
COP Tj = Tbiv
2.45
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.00 kW
5.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.45
1.65
WTOL
65 °C
65 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
30 W
30 W
Supplementary Heater: Type of energy input
n/a
Electricity
Supplementary Heater: PSUP
0.00 kW
0.90 kW
Annual energy consumption Qhe
2666 kWh
3837 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.00 kW
5.50 kW
El input
1.43 kW
2.04 kW
COP
4.90
2.70
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
126 %
Prated
6.00 kW
6.00 kW
SCOP
4.65
3.23
Tbiv
-10 °C
-7 °C
TOL
-15 °C
-15 °C
Pdh Tj = -7°C
5.10 kW
5.30 kW
COP Tj = -7°C
2.80
2.05
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
3.10 kW
3.20 kW
COP Tj = +2°C
4.50
3.10
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
2.40 kW
3.00 kW
COP Tj = +7°C
6.50
4.50
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
2.80 kW
3.60 kW
COP Tj = 12°C
9.00
6.80
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
5.80 kW
5.30 kW
COP Tj = Tbiv
2.50
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.80 kW
5.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.50
1.65
WTOL
65 °C
65 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
30 W
30 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.20 kW
0.90 kW
Annual energy consumption Qhe
2575 kWh
3837 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.50 kW
5.50 kW
El input
1.12 kW
2.04 kW
COP
4.90
2.70
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
126 %
Prated
6.00 kW
6.00 kW
SCOP
4.65
3.23
Tbiv
-10 °C
-7 °C
TOL
-15 °C
-15 °C
Pdh Tj = -7°C
4.90 kW
5.30 kW
COP Tj = -7°C
2.80
2.05
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
3.00 kW
3.20 kW
COP Tj = +2°C
4.50
3.10
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
2.20 kW
3.00 kW
COP Tj = +7°C
6.40
4.50
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
2.60 kW
3.60 kW
COP Tj = 12°C
9.20
6.80
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
5.50 kW
5.30 kW
COP Tj = Tbiv
2.50
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.50 kW
5.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.50
1.65
WTOL
65 °C
65 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
30 W
30 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.50 kW
0.90 kW
Annual energy consumption Qhe
2444 kWh
3837 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.00 kW
5.50 kW
El input
1.94 kW
2.04 kW
COP
4.65
2.70
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
126 %
Prated
6.00 kW
6.00 kW
SCOP
4.65
3.23
Tbiv
-10 °C
-7 °C
TOL
-15 °C
-15 °C
Pdh Tj = -7°C
5.30 kW
5.30 kW
COP Tj = -7°C
2.75
2.05
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
3.20 kW
3.20 kW
COP Tj = +2°C
4.50
3.10
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
2.30 kW
3.00 kW
COP Tj = +7°C
6.50
4.50
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
2.80 kW
3.60 kW
COP Tj = 12°C
9.00
6.80
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
6.00 kW
5.30 kW
COP Tj = Tbiv
2.45
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.00 kW
5.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.45
1.65
WTOL
65 °C
65 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
30 W
30 W
Supplementary Heater: Type of energy input
n/a
Electricity
Supplementary Heater: PSUP
0.00 kW
0.90 kW
Annual energy consumption Qhe
2666 kWh
3837 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.00 kW
5.50 kW
El input
1.43 kW
2.04 kW
COP
4.90
2.70
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
126 %
Prated
6.00 kW
6.00 kW
SCOP
4.65
3.23
Tbiv
-10 °C
-7 °C
TOL
-15 °C
-15 °C
Pdh Tj = -7°C
5.10 kW
5.30 kW
COP Tj = -7°C
2.80
2.05
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
3.10 kW
3.20 kW
COP Tj = +2°C
4.50
3.10
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
2.40 kW
3.00 kW
COP Tj = +7°C
6.50
4.50
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
2.80 kW
3.60 kW
COP Tj = 12°C
9.00
6.80
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
5.80 kW
5.30 kW
COP Tj = Tbiv
2.50
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.80 kW
5.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.50
1.65
WTOL
65 °C
65 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
30 W
30 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.20 kW
0.90 kW
Annual energy consumption Qhe
2575 kWh
3837 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.50 kW
5.50 kW
El input
1.12 kW
2.04 kW
COP
4.90
2.70
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
126 %
Prated
6.00 kW
6.00 kW
SCOP
4.65
3.23
Tbiv
-10 °C
-7 °C
TOL
-15 °C
-15 °C
Pdh Tj = -7°C
4.90 kW
5.30 kW
COP Tj = -7°C
2.80
2.05
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
3.00 kW
3.20 kW
COP Tj = +2°C
4.50
3.10
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
2.20 kW
3.00 kW
COP Tj = +7°C
6.40
4.50
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
2.60 kW
3.60 kW
COP Tj = 12°C
9.20
6.80
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
5.50 kW
5.30 kW
COP Tj = Tbiv
2.50
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.50 kW
5.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.50
1.65
WTOL
65 °C
65 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
30 W
30 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.50 kW
0.90 kW
Annual energy consumption Qhe
2444 kWh
3837 kWh