Certificate holders

Subtype

Alféa Excellia 14

Certificate Holder
Groupe Atlantic
44 boulevard des Etats-Unis
85000 La Roche Sur Yon
France
Registration number
012-001 / 4
Certification Body
RISE CERT
Subtype title
Alféa Excellia 14
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

2,500 kg

Certification Date
09.12.2022
Testing basis
EN 14511:2013, EN 16147:2011, EN 14825:2013, EN 12102:2013
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

Alféa Excellia 14
Configure model
Model name
Alféa Excellia 14
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

13.50 kW

9.48 kW

El input

3.23 kW

3.95 kW

COP

4.18

2.40

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

69 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

148 %

113 %

Prated

12.50 kW

11.30 kW

SCOP

3.77

2.90

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.10 kW

10.00 kW

COP Tj = -7°C

2.50

1.90

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.70 kW

6.10 kW

COP Tj = +2°C

3.60

2.80

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.20 kW

5.90 kW

COP Tj = +7°C

5.40

3.90

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.30 kW

7.10 kW

COP Tj = 12°C

6.90

5.10

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.10 kW

10.00 kW

COP Tj = Tbiv

2.50

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.80 kW

9.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.70

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

8 W

8 W

PTO

72 W

25 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.70 kW

2.00 kW

Annual energy consumption Qhe

6824 kWh

8041 kWh

Alféa Excellia A.I. 14
Configure model
Model name
Alféa Excellia A.I. 14
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

13.50 kW

9.48 kW

El input

3.23 kW

3.95 kW

COP

4.18

2.40

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

69 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

148 %

113 %

Prated

12.50 kW

11.30 kW

SCOP

3.77

2.90

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.10 kW

10.00 kW

COP Tj = -7°C

2.50

1.90

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.70 kW

6.10 kW

COP Tj = +2°C

3.60

2.80

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.20 kW

5.90 kW

COP Tj = +7°C

5.40

3.90

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.30 kW

7.10 kW

COP Tj = 12°C

6.90

5.10

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.10 kW

10.00 kW

COP Tj = Tbiv

2.50

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.80 kW

9.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.70

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

8 W

8 W

PTO

72 W

25 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.70 kW

2.00 kW

Annual energy consumption Qhe

6824 kWh

8041 kWh

Alféa Excellia Duo 14
Configure model
Model name
Alféa Excellia Duo 14
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

13.50 kW

9.48 kW

El input

3.23 kW

3.95 kW

COP

4.18

2.40

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

69 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

148 %

113 %

Prated

12.50 kW

11.30 kW

SCOP

3.77

2.90

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.10 kW

10.00 kW

COP Tj = -7°C

2.50

1.90

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.70 kW

6.10 kW

COP Tj = +2°C

3.60

2.80

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.20 kW

5.90 kW

COP Tj = +7°C

5.40

3.90

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.30 kW

7.10 kW

COP Tj = 12°C

6.90

5.10

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.10 kW

10.00 kW

COP Tj = Tbiv

2.50

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.80 kW

9.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.70

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

8 W

8 W

PTO

72 W

25 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.70 kW

2.00 kW

Annual energy consumption Qhe

6824 kWh

8041 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

88 %

COP

2.25

Heating up time

0:46 h:min

Standby power input

40.0 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C

250 l

Alféa Excellia Duo A.I. 14
Configure model
Model name
Alféa Excellia Duo A.I. 14
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

13.50 kW

9.48 kW

El input

3.23 kW

3.95 kW

COP

4.18

2.40

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

69 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

148 %

113 %

Prated

12.50 kW

11.30 kW

SCOP

3.77

2.90

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.10 kW

10.00 kW

COP Tj = -7°C

2.50

1.90

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.70 kW

6.10 kW

COP Tj = +2°C

3.60

2.80

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.20 kW

5.90 kW

COP Tj = +7°C

5.40

3.90

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.30 kW

7.10 kW

COP Tj = 12°C

6.90

5.10

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.10 kW

10.00 kW

COP Tj = Tbiv

2.50

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.80 kW

9.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.70

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

8 W

8 W

PTO

72 W

25 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.70 kW

2.00 kW

Annual energy consumption Qhe

6824 kWh

8041 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

88 %

COP

2.25

Heating up time

0:46 h:min

Standby power input

40.0 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C

250 l