4,600 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
15.21 kW
14.80 kW
El input
3.52 kW
5.35 kW
COP
4.32
2.76
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
4.52 kW
Cooling capacity
14.65
EER
3.24
EN 14825
+7°C/+12°C
Pdesignc
14.65 kW
SEER
5.06
Pdc Tj = 35°C
14.65 kW
EER Tj = 35°C
3.24
Pdc Tj = 30°C
10.79 kW
EER Tj = 30°C
4.71
Cdc Tj = 30 °C
1.0
Pdc Tj = 25°C
6.93 kW
EER Tj = 25°C
5.81
Cdc Tj = 25 °C
1.0
Pdc Tj = 20°C
7.03 kW
EER Tj = 20°C
6.28
Cdc Tj = 20 °C
1.0
Poff
12 W
PTO
0 W
PSB
12 W
PCK
0 W
Annual energy consumption Qce
1013 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
157 %
123 %
Prated
10.00 kW
9.00 kW
SCOP
4.00
3.14
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.80 kW
9.10 kW
COP Tj = -7°C
2.55
1.65
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
6.00 kW
6.40 kW
COP Tj = +2°C
4.02
3.08
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
6.90 kW
7.60 kW
COP Tj = +7°C
5.11
4.43
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
7.80 kW
7.90 kW
COP Tj = 12°C
5.42
6.50
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
9.80 kW
9.10 kW
COP Tj = Tbiv
2.55
1.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.70 kW
7.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.30
WTOL
39 °C
39 °C
Poff
0 W
0 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3888 kWh
4576 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
15.21 kW
14.80 kW
El input
3.52 kW
5.35 kW
COP
4.32
2.76
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
4.52 kW
Cooling capacity
14.65
EER
3.24
EN 14825
+7°C/+12°C
Pdesignc
14.65 kW
SEER
5.06
Pdc Tj = 35°C
14.65 kW
EER Tj = 35°C
3.24
Pdc Tj = 30°C
10.79 kW
EER Tj = 30°C
4.71
Cdc Tj = 30 °C
1.0
Pdc Tj = 25°C
6.93 kW
EER Tj = 25°C
5.81
Cdc Tj = 25 °C
1.0
Pdc Tj = 20°C
7.03 kW
EER Tj = 20°C
6.28
Cdc Tj = 20 °C
1.0
Poff
12 W
PTO
0 W
PSB
12 W
PCK
0 W
Annual energy consumption Qce
1013 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
157 %
123 %
Prated
10.00 kW
9.00 kW
SCOP
4.00
3.14
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.80 kW
9.10 kW
COP Tj = -7°C
2.55
1.65
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
6.00 kW
6.40 kW
COP Tj = +2°C
4.02
3.08
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
6.90 kW
7.60 kW
COP Tj = +7°C
5.11
4.43
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
7.80 kW
7.90 kW
COP Tj = 12°C
5.42
6.50
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
9.80 kW
9.10 kW
COP Tj = Tbiv
2.55
1.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.70 kW
7.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.30
WTOL
39 °C
39 °C
Poff
0 W
0 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3888 kWh
4576 kWh