3,450 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.00 kW
9.01 kW
El input
2.30 kW
3.89 kW
COP
4.34
2.32
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
2.43 kW
Cooling capacity
7.56
EER
3.11
EN 14825
+7°C/+12°C
Pdesignc
7.56 kW
SEER
4.91
Pdc Tj = 35°C
7.56 kW
EER Tj = 35°C
3.11
Pdc Tj = 30°C
5.57 kW
EER Tj = 30°C
4.48
Cdc Tj = 30 °C
1.0
Pdc Tj = 25°C
5.42 kW
EER Tj = 25°C
5.89
Cdc Tj = 25 °C
1.0
Pdc Tj = 20°C
5.73 kW
EER Tj = 20°C
6.59
Cdc Tj = 20 °C
1.0
Poff
12 W
PTO
0 W
PSB
12 W
PCK
0 W
Annual energy consumption Qce
539 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
161 %
123 %
Prated
6.00 kW
6.00 kW
SCOP
4.10
3.16
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.30 kW
5.50 kW
COP Tj = -7°C
2.59
1.65
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
4.30 kW
4.00 kW
COP Tj = +2°C
3.95
3.15
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
5.30 kW
5.00 kW
COP Tj = +7°C
5.38
4.45
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
5.50 kW
5.30 kW
COP Tj = 12°C
7.15
6.02
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
6.30 kW
5.50 kW
COP Tj = Tbiv
2.59
1.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.60 kW
4.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.44
1.25
WTOL
39 °C
39 °C
Poff
0 W
0 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2417 kWh
2755 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.10 kW
10.06 kW
El input
2.95 kW
3.90 kW
COP
4.10
2.58
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
2.74 kW
Cooling capacity
8.49
EER
3.10
EN 14825
+7°C/+12°C
Pdesignc
8.49 kW
SEER
4.93
Pdc Tj = 35°C
8.49 kW
EER Tj = 35°C
3.10
Pdc Tj = 30°C
6.26 kW
EER Tj = 30°C
4.48
Cdc Tj = 30 °C
1.0
Pdc Tj = 25°C
5.42 kW
EER Tj = 25°C
5.89
Cdc Tj = 25 °C
1.0
Pdc Tj = 20°C
5.73 kW
EER Tj = 20°C
6.59
Cdc Tj = 20 °C
1.0
Poff
12 W
PTO
0 W
PSB
12 W
PCK
0 W
Annual energy consumption Qce
603 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
168 %
126 %
Prated
7.00 kW
7.00 kW
SCOP
4.28
3.23
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.40 kW
6.70 kW
COP Tj = -7°C
2.73
2.00
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
5.70 kW
4.70 kW
COP Tj = +2°C
4.34
3.18
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
4.00 kW
6.00 kW
COP Tj = +7°C
5.15
4.19
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
4.70 kW
6.90 kW
COP Tj = 12°C
6.78
5.27
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
7.40 kW
6.70 kW
COP Tj = Tbiv
2.73
2.00
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.60 kW
5.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.38
1.59
WTOL
39 °C
39 °C
Poff
0 W
0 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2736 kWh
3267 kWh