2,200 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.01 kW
6.89 kW
El input
1.89 kW
3.09 kW
COP
4.24
2.23
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
2.11 kW
Cooling capacity
6.12
EER
2.90
EN 14825
+7°C/+12°C
Pdesignc
6.12 kW
SEER
3.84
Pdc Tj = 35°C
6.12 kW
EER Tj = 35°C
2.90
Pdc Tj = 30°C
4.51 kW
EER Tj = 30°C
3.88
Cdc Tj = 30 °C
1.0
Pdc Tj = 25°C
3.40 kW
EER Tj = 25°C
4.09
Cdc Tj = 25 °C
1.0
Pdc Tj = 20°C
3.68 kW
EER Tj = 20°C
4.92
Cdc Tj = 20 °C
1.0
Poff
12 W
PTO
0 W
PSB
12 W
PCK
0 W
Annual energy consumption Qce
558 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
155 %
124 %
Prated
6.00 kW
5.00 kW
SCOP
3.94
3.17
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.50 kW
5.00 kW
COP Tj = -7°C
2.62
1.72
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
3.40 kW
3.30 kW
COP Tj = +2°C
4.19
3.10
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
3.60 kW
4.00 kW
COP Tj = +7°C
4.39
4.42
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
3.70 kW
4.40 kW
COP Tj = 12°C
5.12
6.18
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
5.50 kW
5.00 kW
COP Tj = Tbiv
2.62
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.10 kW
4.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.33
1.44
WTOL
39 °C
39 °C
Poff
0 W
0 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2216 kWh
2493 kWh