2,250 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
13.01 kW
11.80 kW
El input
2.74 kW
3.94 kW
COP
4.75
2.94
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
50 dB(A)
50 dB(A)
Sound power level outdoor
0 dB(A)
0 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
199 %
138 %
Prated
13.00 kW
12.00 kW
SCOP
5.17
3.64
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.00 kW
11.70 kW
COP Tj = -7°C
4.80
3.07
Pdh Tj = +2°C
13.20 kW
12.20 kW
COP Tj = +2°C
5.11
3.58
Pdh Tj = +7°C
13.30 kW
12.50 kW
COP Tj = +7°C
5.41
3.97
Pdh Tj = 12°C
13.50 kW
12.80 kW
COP Tj = 12°C
5.75
4.43
Pdh Tj = Tbiv
13.00 kW
11.60 kW
COP Tj = Tbiv
4.75
2.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.00 kW
11.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.75
2.94
Rated airflow rate
0 m³/h
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
60 °C
60 °C
Poff
0 W
0 W
PTO
85 W
85 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5195 kWh
6571 kWh
Heating
EN 14511-2
Heat output
13.01 kW
El input
2.74 kW
COP
4.75
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Sound power level indoor
50 dB(A)
Sound power level outdoor
0 dB(A)
EN 14825
ηs
199 %
Prated
13.00 kW
SCOP
3.94
Tbiv
2 °C
TOL
2 °C
Pdh Tj = -7°C
0.00 kW
COP Tj = -7°C
0.00
Pdh Tj = +2°C
13.00 kW
COP Tj = +2°C
4.75
Pdh Tj = +7°C
13.20 kW
COP Tj = +7°C
5.04
Pdh Tj = 12°C
13.40 kW
COP Tj = 12°C
5.53
Pdh Tj = Tbiv
13.00 kW
COP Tj = Tbiv
4.75
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.75
Rated airflow rate
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
WTOL
60 °C
Poff
0 W
PTO
85 W
PSB
10 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.00 kW
Annual energy consumption Qhe
3366 kWh
Colder Climate
EN 12102-1
Sound power level indoor
50 dB(A)
Sound power level outdoor
0 dB(A)
EN 14825
ηs
204 %
Prated
16.00 kW
SCOP
4.39
Tbiv
-15 °C
TOL
-22 °C
Pdh Tj = -7°C
13.30 kW
COP Tj = -7°C
5.27
Pdh Tj = +2°C
13.40 kW
COP Tj = +2°C
5.50
Pdh Tj = +7°C
13.50 kW
COP Tj = +7°C
5.70
Pdh Tj = 12°C
13.50 kW
COP Tj = 12°C
5.73
Pdh Tj = Tbiv
13.20 kW
COP Tj = Tbiv
5.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.17
Rated airflow rate
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
WTOL
60 °C
Poff
0 W
PTO
85 W
PSB
10 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
3.20 kW
Annual energy consumption Qhe
7530 kWh
Average Climate
EN 12102-1
Sound power level indoor
50 dB(A)
Sound power level outdoor
0 dB(A)
EN 14825
ηs
199 %
Prated
13.00 kW
SCOP
5.17
Tbiv
-10 °C
TOL
-10 °C
Pdh Tj = -7°C
13.00 kW
COP Tj = -7°C
4.80
Pdh Tj = +2°C
13.20 kW
COP Tj = +2°C
5.11
Pdh Tj = +7°C
13.30 kW
COP Tj = +7°C
5.41
Pdh Tj = 12°C
13.50 kW
COP Tj = 12°C
5.75
Pdh Tj = Tbiv
13.00 kW
COP Tj = Tbiv
4.75
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.75
Rated airflow rate
0 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
WTOL
60 °C
Poff
0 W
PTO
85 W
PSB
10 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.00 kW
Annual energy consumption Qhe
5195 kWh