2,900 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.21 kW
4.73 kW
El input
1.09 kW
1.54 kW
COP
4.78
3.07
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
174 %
132 %
Prated
11.50 kW
10.00 kW
SCOP
4.42
3.37
Tbiv
-7 °C
-8 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.30 kW
8.90 kW
COP Tj = -7°C
2.91
1.99
Pdh Tj = +2°C
6.30 kW
5.50 kW
COP Tj = +2°C
4.34
3.22
Pdh Tj = +7°C
4.10 kW
3.50 kW
COP Tj = +7°C
5.51
4.61
Pdh Tj = 12°C
4.80 kW
5.00 kW
COP Tj = 12°C
6.96
6.25
Pdh Tj = Tbiv
10.20 kW
9.20 kW
COP Tj = Tbiv
2.89
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.30 kW
8.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.66
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.97
0.98
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
20 W
15 W
PSB
15 W
15 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.20 kW
1.90 kW
Annual energy consumption Qhe
5482 kWh
6136 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
98 %
COP
2.32
Heating up time
1:00 h:min
Standby power input
85.0 W
Reference hot water temperature
51.0 °C
Mixed water at 40°C
230 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.21 kW
4.73 kW
El input
1.09 kW
1.54 kW
COP
4.78
3.07
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
174 %
132 %
Prated
11.50 kW
10.00 kW
SCOP
4.42
3.37
Tbiv
-7 °C
-8 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.30 kW
8.90 kW
COP Tj = -7°C
2.91
1.99
Pdh Tj = +2°C
6.30 kW
5.50 kW
COP Tj = +2°C
4.34
3.22
Pdh Tj = +7°C
4.10 kW
3.50 kW
COP Tj = +7°C
5.51
4.61
Pdh Tj = 12°C
4.80 kW
5.00 kW
COP Tj = 12°C
6.96
6.25
Pdh Tj = Tbiv
10.20 kW
9.20 kW
COP Tj = Tbiv
2.89
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.30 kW
8.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.66
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.97
0.98
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
20 W
15 W
PSB
15 W
15 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.20 kW
1.90 kW
Annual energy consumption Qhe
5482 kWh
6136 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
98 %
COP
2.32
Heating up time
1:00 h:min
Standby power input
85.0 W
Reference hot water temperature
51.0 °C
Mixed water at 40°C
230 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.21 kW
4.73 kW
El input
1.09 kW
1.54 kW
COP
4.78
3.07
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
174 %
132 %
Prated
11.50 kW
10.00 kW
SCOP
4.42
3.37
Tbiv
-7 °C
-8 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.30 kW
8.90 kW
COP Tj = -7°C
2.91
1.99
Pdh Tj = +2°C
6.30 kW
5.50 kW
COP Tj = +2°C
4.34
3.22
Pdh Tj = +7°C
4.10 kW
3.50 kW
COP Tj = +7°C
5.51
4.61
Pdh Tj = 12°C
4.80 kW
5.00 kW
COP Tj = 12°C
6.96
6.25
Pdh Tj = Tbiv
10.20 kW
9.20 kW
COP Tj = Tbiv
2.89
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.30 kW
8.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.66
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.97
0.98
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
20 W
15 W
PSB
15 W
15 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.20 kW
1.90 kW
Annual energy consumption Qhe
5482 kWh
6136 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.21 kW
4.73 kW
El input
1.09 kW
1.54 kW
COP
4.78
3.07
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
174 %
132 %
Prated
11.50 kW
10.00 kW
SCOP
4.42
3.37
Tbiv
-7 °C
-8 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.30 kW
8.90 kW
COP Tj = -7°C
2.91
1.99
Pdh Tj = +2°C
6.30 kW
5.50 kW
COP Tj = +2°C
4.34
3.22
Pdh Tj = +7°C
4.10 kW
3.50 kW
COP Tj = +7°C
5.51
4.61
Pdh Tj = 12°C
4.80 kW
5.00 kW
COP Tj = 12°C
6.96
6.25
Pdh Tj = Tbiv
10.20 kW
9.20 kW
COP Tj = Tbiv
2.89
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.30 kW
8.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.66
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.97
0.98
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
20 W
15 W
PSB
15 W
15 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.20 kW
1.90 kW
Annual energy consumption Qhe
5482 kWh
6136 kWh