Certificate holders

Subtype

Vitocal 2xx-S ODU3

Certificate Holder
Viessmann Climate Solutions SE
Viessmannstr. 1
35107 Allendorf/Eder
Germany
Registration number
011-1W0201
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Vitocal 2xx-S ODU3
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

3,600 kg

Certification Date
15.03.2018
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 18

Models

Vitocal 200-S AWB-M-E-AC 201.D10
Configure model
Model name
Vitocal 200-S AWB-M-E-AC 201.D10
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.01 kW

7.93 kW

El input

1.49 kW

2.73 kW

COP

4.69

2.90

EN 14825

Pdesignh

9.32 kW

Rated airflow rate

4500 m³/h

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

129 %

Prated

9.32 kW

9.35 kW

SCOP

4.47

3.29

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

8.25 kW

8.27 kW

COP Tj = -7°C

3.24

2.26

Pdh Tj = +2°C

5.32 kW

6.07 kW

COP Tj = +2°C

4.32

3.15

Pdh Tj = +7°C

6.60 kW

5.37 kW

COP Tj = +7°C

5.81

4.21

Pdh Tj = 12°C

6.63 kW

6.41 kW

COP Tj = 12°C

7.51

5.70

Pdh Tj = Tbiv

8.25 kW

8.27 kW

COP Tj = Tbiv

3.24

2.26

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.51 kW

8.04 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

0 W

0 W

PSB

25 W

25 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.86 kW

1.36 kW

Annual energy consumption Qhe

4314 kWh

5689 kWh

Vitocal 200-S AWB-M-E-AC 201.D13
Configure model
Model name
Vitocal 200-S AWB-M-E-AC 201.D13
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.85 kW

7.93 kW

El input

1.66 kW

2.73 kW

COP

4.72

2.90

EN 14825

Pdesignh

9.99 kW

Rated airflow rate

4500 m³/h

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

130 %

Prated

9.99 kW

10.07 kW

SCOP

4.46

3.32

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

8.83 kW

8.91 kW

COP Tj = -7°C

3.19

2.27

Pdh Tj = +2°C

5.71 kW

5.90 kW

COP Tj = +2°C

4.30

3.17

Pdh Tj = +7°C

8.86 kW

5.38 kW

COP Tj = +7°C

5.63

4.24

Pdh Tj = 12°C

6.65 kW

6.42 kW

COP Tj = 12°C

7.64

5.72

Pdh Tj = Tbiv

8.83 kW

8.91 kW

COP Tj = Tbiv

3.19

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.06 kW

8.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

0 W

0 W

PSB

25 W

25 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.98 kW

1.54 kW

Annual energy consumption Qhe

4625 kWh

6275 kWh

Vitocal 200-S AWB-M-E-AC 201.D16
Configure model
Model name
Vitocal 200-S AWB-M-E-AC 201.D16
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

8.64 kW

8.42 kW

El input

1.90 kW

2.89 kW

COP

4.54

2.92

EN 14825

Pdesignh

10.61 kW

Rated airflow rate

4500 m³/h

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

130 %

Prated

10.61 kW

10.72 kW

SCOP

4.46

3.34

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

9.39 kW

9.49 kW

COP Tj = -7°C

3.12

2.26

Pdh Tj = +2°C

5.72 kW

5.91 kW

COP Tj = +2°C

4.29

3.19

Pdh Tj = +7°C

8.88 kW

5.39 kW

COP Tj = +7°C

5.68

4.27

Pdh Tj = 12°C

6.67 kW

6.42 kW

COP Tj = 12°C

7.74

5.75

Pdh Tj = Tbiv

9.39 kW

9.49 kW

COP Tj = Tbiv

3.12

2.26

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.55 kW

9.21 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

60 °C

60 °C

Poff

59 W

59 W

PTO

0 W

0 W

PSB

25 W

25 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.11 kW

1.57 kW

Annual energy consumption Qhe

4917 kWh

6638 kWh

Vitocal 200-S AWB-M 201.D10
Configure model
Model name
Vitocal 200-S AWB-M 201.D10
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.01 kW

7.93 kW

El input

1.49 kW

2.73 kW

COP

4.69

2.90

EN 14825

Pdesignh

9.32 kW

Rated airflow rate

4500 m³/h

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

129 %

Prated

9.32 kW

9.35 kW

SCOP

4.47

3.29

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

8.25 kW

8.27 kW

COP Tj = -7°C

3.24

2.26

Pdh Tj = +2°C

5.32 kW

6.07 kW

COP Tj = +2°C

4.32

3.15

Pdh Tj = +7°C

6.60 kW

5.37 kW

COP Tj = +7°C

5.81

4.21

Pdh Tj = 12°C

6.63 kW

6.41 kW

COP Tj = 12°C

7.51

5.70

Pdh Tj = Tbiv

8.25 kW

8.27 kW

COP Tj = Tbiv

3.24

2.26

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.51 kW

8.04 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

0 W

0 W

PSB

25 W

25 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.86 kW

1.36 kW

Annual energy consumption Qhe

4314 kWh

5867 kWh

Vitocal 200-S AWB-M 201.D13
Configure model
Model name
Vitocal 200-S AWB-M 201.D13
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.85 kW

7.93 kW

El input

1.66 kW

2.73 kW

COP

4.72

2.90

EN 14825

Pdesignh

9.99 kW

Rated airflow rate

4500 m³/h

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

130 %

Prated

9.99 kW

10.07 kW

SCOP

4.46

3.32

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

8.83 kW

8.91 kW

COP Tj = -7°C

3.19

2.27

Pdh Tj = +2°C

5.71 kW

5.90 kW

COP Tj = +2°C

4.30

3.17

Pdh Tj = +7°C

8.86 kW

5.38 kW

COP Tj = +7°C

5.63

4.24

Pdh Tj = 12°C

6.65 kW

6.42 kW

COP Tj = 12°C

7.64

5.72

Pdh Tj = Tbiv

8.83 kW

8.91 kW

COP Tj = Tbiv

3.19

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.06 kW

8.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

0 W

0 W

PSB

25 W

25 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.98 kW

1.54 kW

Annual energy consumption Qhe

4625 kWh

6275 kWh

Vitocal 200-S AWB-M 201.D16
Configure model
Model name
Vitocal 200-S AWB-M 201.D16
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

8.64 kW

8.42 kW

El input

1.90 kW

2.89 kW

COP

4.54

2.92

EN 14825

Pdesignh

10.61 kW

Rated airflow rate

4500 m³/h

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

130 %

Prated

10.61 kW

10.72 kW

SCOP

4.46

3.34

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

9.39 kW

9.49 kW

COP Tj = -7°C

3.12

2.26

Pdh Tj = +2°C

5.72 kW

5.91 kW

COP Tj = +2°C

4.29

3.19

Pdh Tj = +7°C

8.88 kW

5.39 kW

COP Tj = +7°C

5.68

4.27

Pdh Tj = 12°C

6.67 kW

6.42 kW

COP Tj = 12°C

7.74

5.75

Pdh Tj = Tbiv

9.39 kW

9.49 kW

COP Tj = Tbiv

3.12

2.26

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.55 kW

9.21 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

60 °C

60 °C

Poff

59 W

59 W

PTO

0 W

0 W

PSB

25 W

25 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.11 kW

1.57 kW

Annual energy consumption Qhe

4917 kWh

6638 kWh

Vitocal 200-S AWB-E-M 201.D10
Configure model
Model name
Vitocal 200-S AWB-E-M 201.D10
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.01 kW

7.93 kW

El input

1.49 kW

2.73 kW

COP

4.69

2.90

EN 14825

Pdesignh

9.32 kW

Rated airflow rate

4500 m³/h

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

129 %

Prated

9.32 kW

9.35 kW

SCOP

4.47

3.29

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

8.25 kW

8.27 kW

COP Tj = -7°C

3.24

2.26

Pdh Tj = +2°C

5.32 kW

6.07 kW

COP Tj = +2°C

4.32

3.15

Pdh Tj = +7°C

6.60 kW

5.37 kW

COP Tj = +7°C

5.81

4.21

Pdh Tj = 12°C

6.63 kW

6.41 kW

COP Tj = 12°C

7.51

5.70

Pdh Tj = Tbiv

8.25 kW

8.27 kW

COP Tj = Tbiv

3.24

2.26

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.51 kW

8.04 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

0 W

0 W

PSB

25 W

25 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.86 kW

1.36 kW

Annual energy consumption Qhe

4314 kWh

5867 kWh

Vitocal 200-S AWB-E-M 201.D13
Configure model
Model name
Vitocal 200-S AWB-E-M 201.D13
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.85 kW

7.93 kW

El input

1.66 kW

2.73 kW

COP

4.72

2.90

EN 14825

Pdesignh

9.99 kW

Rated airflow rate

4500 m³/h

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

130 %

Prated

9.99 kW

10.07 kW

SCOP

4.46

3.32

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

8.83 kW

8.91 kW

COP Tj = -7°C

3.19

2.27

Pdh Tj = +2°C

5.71 kW

5.90 kW

COP Tj = +2°C

4.30

3.17

Pdh Tj = +7°C

8.86 kW

5.38 kW

COP Tj = +7°C

5.63

4.24

Pdh Tj = 12°C

6.65 kW

6.42 kW

COP Tj = 12°C

7.64

5.72

Pdh Tj = Tbiv

8.83 kW

8.91 kW

COP Tj = Tbiv

3.19

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.06 kW

8.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

0 W

0 W

PSB

25 W

25 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.98 kW

1.54 kW

Annual energy consumption Qhe

4625 kWh

6275 kWh

Vitocal 200-S AWB-E-M 201.D16
Configure model
Model name
Vitocal 200-S AWB-E-M 201.D16
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

8.64 kW

8.42 kW

El input

1.90 kW

2.89 kW

COP

4.54

2.92

EN 14825

Pdesignh

10.61 kW

Rated airflow rate

4500 m³/h

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

130 %

Prated

10.61 kW

10.72 kW

SCOP

4.46

3.34

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

9.39 kW

9.49 kW

COP Tj = -7°C

3.12

2.26

Pdh Tj = +2°C

5.72 kW

5.91 kW

COP Tj = +2°C

4.29

3.19

Pdh Tj = +7°C

8.88 kW

5.39 kW

COP Tj = +7°C

5.68

4.27

Pdh Tj = 12°C

6.67 kW

6.42 kW

COP Tj = 12°C

7.74

5.75

Pdh Tj = Tbiv

9.39 kW

9.49 kW

COP Tj = Tbiv

3.12

2.26

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.55 kW

9.21 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

60 °C

60 °C

Poff

59 W

59 W

PTO

0 W

0 W

PSB

25 W

25 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.11 kW

1.57 kW

Annual energy consumption Qhe

4917 kWh

6638 kWh

Vitocal 222-S AWBT-M 221.C10
Configure model
Model name
Vitocal 222-S AWBT-M 221.C10
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.01 kW

7.93 kW

El input

1.49 kW

2.73 kW

COP

4.69

2.90

EN 14825

Pdesignh

9.32 kW

Rated airflow rate

4500 m³/h

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

129 %

Prated

9.32 kW

9.35 kW

SCOP

4.47

3.29

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

8.25 kW

8.27 kW

COP Tj = -7°C

3.24

2.26

Pdh Tj = +2°C

5.32 kW

6.07 kW

COP Tj = +2°C

4.32

3.15

Pdh Tj = +7°C

6.60 kW

5.37 kW

COP Tj = +7°C

5.81

4.21

Pdh Tj = 12°C

6.63 kW

6.41 kW

COP Tj = 12°C

7.51

5.70

Pdh Tj = Tbiv

8.25 kW

8.27 kW

COP Tj = Tbiv

3.24

2.26

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.51 kW

8.04 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

0 W

0 W

PSB

25 W

25 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.86 kW

1.36 kW

Annual energy consumption Qhe

4314 kWh

5867 kWh

Vitocal 222-S AWBT-M 221.C13
Configure model
Model name
Vitocal 222-S AWBT-M 221.C13
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.85 kW

7.93 kW

El input

1.66 kW

2.73 kW

COP

4.72

2.90

EN 14825

Pdesignh

9.99 kW

Rated airflow rate

4500 m³/h

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

130 %

Prated

9.99 kW

10.07 kW

SCOP

4.46

3.32

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

8.83 kW

8.91 kW

COP Tj = -7°C

3.19

2.27

Pdh Tj = +2°C

5.71 kW

5.90 kW

COP Tj = +2°C

4.30

3.17

Pdh Tj = +7°C

8.86 kW

5.38 kW

COP Tj = +7°C

5.63

4.24

Pdh Tj = 12°C

6.65 kW

6.42 kW

COP Tj = 12°C

7.64

5.72

Pdh Tj = Tbiv

8.83 kW

8.91 kW

COP Tj = Tbiv

3.19

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.06 kW

8.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

0 W

0 W

PSB

25 W

25 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.98 kW

1.54 kW

Annual energy consumption Qhe

4625 kWh

6275 kWh

Vitocal 222-S AWBT-M 221.C16
Configure model
Model name
Vitocal 222-S AWBT-M 221.C16
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

8.64 kW

8.42 kW

El input

1.90 kW

2.89 kW

COP

4.54

2.92

EN 14825

Pdesignh

10.61 kW

Rated airflow rate

4500 m³/h

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

130 %

Prated

10.61 kW

10.72 kW

SCOP

4.46

3.34

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

9.39 kW

9.49 kW

COP Tj = -7°C

3.12

2.26

Pdh Tj = +2°C

5.72 kW

5.91 kW

COP Tj = +2°C

4.29

3.19

Pdh Tj = +7°C

8.88 kW

5.39 kW

COP Tj = +7°C

5.68

4.27

Pdh Tj = 12°C

6.67 kW

6.42 kW

COP Tj = 12°C

7.74

5.75

Pdh Tj = Tbiv

9.39 kW

9.49 kW

COP Tj = Tbiv

3.12

2.26

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.55 kW

9.21 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

60 °C

60 °C

Poff

59 W

59 W

PTO

0 W

0 W

PSB

25 W

25 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.11 kW

1.57 kW

Annual energy consumption Qhe

4917 kWh

6638 kWh

Vitocal 222-S AWBT-M-E -AC 221.C10
Configure model
Model name
Vitocal 222-S AWBT-M-E -AC 221.C10
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.01 kW

7.93 kW

El input

1.49 kW

2.73 kW

COP

4.69

2.90

EN 14825

Pdesignh

9.32 kW

Rated airflow rate

4500 m³/h

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

129 %

Prated

9.32 kW

9.35 kW

SCOP

4.47

3.29

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

8.25 kW

8.27 kW

COP Tj = -7°C

3.24

2.26

Pdh Tj = +2°C

5.32 kW

6.07 kW

COP Tj = +2°C

4.32

3.15

Pdh Tj = +7°C

6.60 kW

5.37 kW

COP Tj = +7°C

5.81

4.21

Pdh Tj = 12°C

6.63 kW

6.41 kW

COP Tj = 12°C

7.51

5.70

Pdh Tj = Tbiv

8.25 kW

8.27 kW

COP Tj = Tbiv

3.24

2.26

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.51 kW

8.04 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

0 W

0 W

PSB

25 W

25 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.86 kW

1.36 kW

Annual energy consumption Qhe

4314 kWh

5867 kWh

Vitocal 222-S AWBT-M-E-AC 221.C13
Configure model
Model name
Vitocal 222-S AWBT-M-E-AC 221.C13
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.85 kW

7.93 kW

El input

1.66 kW

2.73 kW

COP

4.72

2.90

EN 14825

Pdesignh

9.99 kW

Rated airflow rate

4500 m³/h

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

130 %

Prated

9.99 kW

10.07 kW

SCOP

4.46

3.32

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

8.83 kW

8.91 kW

COP Tj = -7°C

3.19

2.27

Pdh Tj = +2°C

5.71 kW

5.90 kW

COP Tj = +2°C

4.30

3.17

Pdh Tj = +7°C

8.86 kW

5.38 kW

COP Tj = +7°C

5.63

4.24

Pdh Tj = 12°C

6.65 kW

6.42 kW

COP Tj = 12°C

7.64

5.72

Pdh Tj = Tbiv

8.83 kW

8.91 kW

COP Tj = Tbiv

3.19

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.06 kW

8.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

0 W

0 W

PSB

25 W

25 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.98 kW

1.54 kW

Annual energy consumption Qhe

4625 kWh

6275 kWh

Vitocal 222-S AWBT-M-E-AC 221.C16
Configure model
Model name
Vitocal 222-S AWBT-M-E-AC 221.C16
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

8.64 kW

8.42 kW

El input

1.90 kW

2.89 kW

COP

4.54

2.92

EN 14825

Pdesignh

10.61 kW

Rated airflow rate

4500 m³/h

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

130 %

Prated

10.61 kW

10.72 kW

SCOP

4.46

3.34

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

9.39 kW

9.49 kW

COP Tj = -7°C

3.12

2.26

Pdh Tj = +2°C

5.72 kW

5.91 kW

COP Tj = +2°C

4.29

3.19

Pdh Tj = +7°C

8.88 kW

5.39 kW

COP Tj = +7°C

5.68

4.27

Pdh Tj = 12°C

6.67 kW

6.42 kW

COP Tj = 12°C

7.74

5.75

Pdh Tj = Tbiv

9.39 kW

9.49 kW

COP Tj = Tbiv

3.12

2.26

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.55 kW

9.21 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

60 °C

60 °C

Poff

59 W

59 W

PTO

0 W

0 W

PSB

25 W

25 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.11 kW

1.40 kW

Annual energy consumption Qhe

4917 kWh

6638 kWh

Vitocal 222-S AWBT-M-E 221.C10
Configure model
Model name
Vitocal 222-S AWBT-M-E 221.C10
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.01 kW

7.93 kW

El input

1.49 kW

2.73 kW

COP

4.69

2.90

EN 14825

Pdesignh

9.32 kW

Rated airflow rate

4500 m³/h

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

129 %

Prated

9.32 kW

9.35 kW

SCOP

4.47

3.29

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

8.25 kW

8.27 kW

COP Tj = -7°C

3.24

2.26

Pdh Tj = +2°C

5.32 kW

6.07 kW

COP Tj = +2°C

4.32

3.15

Pdh Tj = +7°C

6.60 kW

5.37 kW

COP Tj = +7°C

5.81

4.21

Pdh Tj = 12°C

6.63 kW

6.41 kW

COP Tj = 12°C

7.51

5.70

Pdh Tj = Tbiv

8.25 kW

8.27 kW

COP Tj = Tbiv

3.24

2.26

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.51 kW

8.04 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

0 W

0 W

PSB

25 W

25 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.86 kW

1.36 kW

Annual energy consumption Qhe

4314 kWh

5867 kWh

Vitocal 222-S AWBT-M-E 221.C13
Configure model
Model name
Vitocal 222-S AWBT-M-E 221.C13
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.85 kW

7.93 kW

El input

1.66 kW

2.73 kW

COP

4.72

2.90

EN 14825

Pdesignh

9.99 kW

Rated airflow rate

4500 m³/h

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

130 %

Prated

9.99 kW

10.07 kW

SCOP

4.46

3.32

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

8.83 kW

8.91 kW

COP Tj = -7°C

3.19

2.27

Pdh Tj = +2°C

5.71 kW

5.90 kW

COP Tj = +2°C

4.30

3.17

Pdh Tj = +7°C

8.86 kW

5.38 kW

COP Tj = +7°C

5.63

4.24

Pdh Tj = 12°C

6.65 kW

6.42 kW

COP Tj = 12°C

7.64

5.72

Pdh Tj = Tbiv

8.83 kW

8.91 kW

COP Tj = Tbiv

3.19

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.06 kW

8.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

0 W

0 W

PSB

25 W

25 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.98 kW

1.54 kW

Annual energy consumption Qhe

4625 kWh

6275 kWh

Vitocal 222-S AWBT-M-E 221.C16
Configure model
Model name
Vitocal 222-S AWBT-M-E 221.C16
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

8.64 kW

8.42 kW

El input

1.90 kW

2.89 kW

COP

4.54

2.92

EN 14825

Pdesignh

10.61 kW

Rated airflow rate

4500 m³/h

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

130 %

Prated

10.61 kW

10.72 kW

SCOP

4.46

3.34

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

9.39 kW

9.49 kW

COP Tj = -7°C

3.12

2.26

Pdh Tj = +2°C

5.72 kW

5.91 kW

COP Tj = +2°C

4.29

3.19

Pdh Tj = +7°C

8.88 kW

5.39 kW

COP Tj = +7°C

5.68

4.27

Pdh Tj = 12°C

6.67 kW

6.42 kW

COP Tj = 12°C

7.74

5.75

Pdh Tj = Tbiv

9.39 kW

9.49 kW

COP Tj = Tbiv

3.12

2.26

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.55 kW

9.21 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

2.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

60 °C

60 °C

Poff

59 W

59 W

PTO

0 W

0 W

PSB

25 W

25 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.11 kW

1.57 kW

Annual energy consumption Qhe

4917 kWh

6638 kWh