Certificate holders

Subtype

Austria Email LWP 5 A.I.

Certificate Holder
Groupe Atlantic
44 boulevard des Etats-Unis
85000 La Roche Sur Yon
France
Registration number
012-C700015
Certification Body
RISE CERT
Subtype title
Austria Email LWP 5 A.I.
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

0,970 kg

Certification Date
04.03.2020
Testing basis
HP Keymark Scheme Rules rev 7
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

Austria Email LWP 5 A.I.
Configure model
Model name
Austria Email LWP 5 A.I.
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.50 kW

4.50 kW

El input

0.95 kW

1.70 kW

COP

4.74

2.64

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

125 %

Prated

5.00 kW

5.00 kW

SCOP

4.45

3.20

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.40 kW

4.20 kW

COP Tj = -7°C

2.84

1.99

Cdh Tj = -7 °C

0.96

0.97

Pdh Tj = +2°C

2.70 kW

2.50 kW

COP Tj = +2°C

4.40

3.11

Cdh Tj = +2 °C

0.96

0.97

Pdh Tj = +7°C

2.10 kW

1.90 kW

COP Tj = +7°C

5.85

4.25

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

2.40 kW

2.30 kW

COP Tj = 12°C

7.39

5.91

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

4.40 kW

4.20 kW

COP Tj = Tbiv

2.84

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

1.71

WTOL

55 °C

55 °C

Poff

4 W

4 W

PTO

12 W

13 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

1.00 kW

Annual energy consumption Qhe

2322 kWh

3035 kWh

Austria Email LWPK 5 A.I.
Configure model
Model name
Austria Email LWPK 5 A.I.
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.50 kW

4.50 kW

El input

0.95 kW

1.70 kW

COP

4.74

2.64

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

125 %

Prated

5.00 kW

5.00 kW

SCOP

4.45

3.20

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.40 kW

4.20 kW

COP Tj = -7°C

2.84

1.99

Cdh Tj = -7 °C

0.96

0.97

Pdh Tj = +2°C

2.70 kW

2.50 kW

COP Tj = +2°C

4.40

3.11

Cdh Tj = +2 °C

0.96

0.97

Pdh Tj = +7°C

2.10 kW

1.90 kW

COP Tj = +7°C

5.85

4.25

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

2.40 kW

2.30 kW

COP Tj = 12°C

7.39

5.91

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

4.40 kW

4.20 kW

COP Tj = Tbiv

2.84

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.00 kW

3.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

1.71

WTOL

55 °C

55 °C

Poff

4 W

4 W

PTO

12 W

13 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

1.00 kW

Annual energy consumption Qhe

2322 kWh

3035 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

130 %

COP

3.10

Heating up time

1:35 h:min

Standby power input

30.0 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C