2,000 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.65 kW
4.65 kW
El input
0.93 kW
1.77 kW
COP
5.00
2.63
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
127 %
Prated
7.00 kW
7.00 kW
SCOP
4.47
3.24
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.88 kW
5.83 kW
COP Tj = -7°C
2.91
1.97
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
3.64 kW
3.68 kW
COP Tj = +2°C
4.38
3.22
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
2.42 kW
2.47 kW
COP Tj = +7°C
5.89
4.21
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
1.03 kW
1.26 kW
COP Tj = 12°C
5.89
4.91
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
5.88 kW
5.83 kW
COP Tj = Tbiv
2.91
1.97
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.62 kW
5.86 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.62
WTOL
60 °C
60 °C
Poff
9 W
9 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.70 kW
Annual energy consumption Qhe
3071 kWh
4203 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.65 kW
6.80 kW
El input
1.35 kW
2.42 kW
COP
4.94
2.81
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
127 %
Prated
7.00 kW
7.00 kW
SCOP
4.47
3.24
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.88 kW
5.83 kW
COP Tj = -7°C
2.91
1.97
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
3.64 kW
3.68 kW
COP Tj = +2°C
4.38
3.22
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
2.42 kW
2.47 kW
COP Tj = +7°C
5.89
4.21
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
1.03 kW
1.26 kW
COP Tj = 12°C
5.89
4.91
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
5.88 kW
5.83 kW
COP Tj = Tbiv
2.91
1.97
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.62 kW
5.86 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.62
WTOL
60 °C
60 °C
Poff
9 W
9 W
PTO
6 W
6 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.70 kW
Annual energy consumption Qhe
3701 kWh
4203 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.60 kW
8.60 kW
El input
1.87 kW
3.12 kW
COP
4.60
2.75
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
126 %
Prated
8.00 kW
7.00 kW
SCOP
4.51
3.22
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.42 kW
6.58 kW
COP Tj = -7°C
2.80
1.87
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
4.83 kW
4.25 kW
COP Tj = +2°C
4.33
3.19
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
3.20 kW
2.80 kW
COP Tj = +7°C
6.20
4.38
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
1.55 kW
1.27 kW
COP Tj = 12°C
7.61
5.04
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
7.42 kW
6.58 kW
COP Tj = Tbiv
2.80
1.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.64 kW
5.53 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
1.51
WTOL
60 °C
60 °C
Poff
9 W
9 W
PTO
10 W
10 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.80 kW
1.80 kW
Annual energy consumption Qhe
3844 kWh
4770 kWh