Certificate holders

Subtype

Ecodan Eco Inverter 4-170D

Certificate Holder
Mitsubishi Electric Air Conditioning Systems Europe LTD
Nettlehill Road, Houston Industrial Estate
EH54 5EQ Livingston
United Kingdom
Registration number
037-0005-19 / rev. 2
Certification Body
SZU - Strojirensky zkusebni ustav (Engineering Test Institute, Public Enterprise)
Subtype title
Ecodan Eco Inverter 4-170D
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,200 kg

Certification Date
15.10.2019
Testing basis
HP Keymark scheme rules rev. no. 6
Generate PDF Export model CSV Download certificate
  • Number of models 3

Models

SUZ-SWM40VA + EHST17D-*M*D
Configure model
Model name
SUZ-SWM40VA + EHST17D-*M*D
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4 kW

4.5 kW

El input

0.77 kW

1.72 kW

COP

5.2

2.61

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

216 %

155 %

Prated

5.1 kW

4.6 kW

SCOP

5.46

3.94

Tbiv

2 °C

2 °C

TOL

-20 °C

-20 °C

Pdh Tj = +2°C

5.1 kW

4.6 kW

COP Tj = +2°C

3.25

1.85

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.3 kW

3 kW

COP Tj = +7°C

5.28

3.51

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

1.9 kW

1.9 kW

COP Tj = 12°C

7.04

5.59

Cdh Tj = +12 °C

0.94

0.96

Pdh Tj = Tbiv

5.1 kW

4.6 kW

COP Tj = Tbiv

3.25

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.1 kW

4.6 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.25

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.994

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

1247 kWh

1560 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

129 %

Prated

5.1 kW

4.6 kW

SCOP

4.58

3.29

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.5 kW

4.1 kW

COP Tj = -7°C

2.88

2.02

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.7 kW

2.5 kW

COP Tj = +2°C

4.5

3.2

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

2.6 kW

2.6 kW

COP Tj = +7°C

6.5

4.64

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

2.6 kW

2.3 kW

COP Tj = 12°C

8.97

6.57

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

4.5 kW

4.1 kW

COP Tj = Tbiv

2.88

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.36 kW

4.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.91

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.991

0.993

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.74 kW

0.55 kW

Annual energy consumption Qhe

2301 kWh

2888 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

167 %

COP

4

Heating up time

02:00 h:min

Standby power input

23 W

Reference hot water temperature

55.5 °C

Mixed water at 40°C

236 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

148 %

COP

3.55

Heating up time

02:25 h:min

Standby power input

26 W

Reference hot water temperature

55.5 °C

Mixed water at 40°C

236 l

SUZ-SWM40VA + ERST17D-*M*D
Configure model
Model name
SUZ-SWM40VA + ERST17D-*M*D
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4 kW

4.5 kW

El input

0.77 kW

1.72 kW

COP

5.2

2.61

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

225 %

160 %

Prated

5.1 kW

4.6 kW

SCOP

5.7

4.08

Tbiv

2 °C

2 °C

TOL

-20 °C

-20 °C

Pdh Tj = +2°C

5.1 kW

4.6 kW

COP Tj = +2°C

3.13

1.85

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.3 kW

3 kW

COP Tj = +7°C

5.18

3.45

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

1.9 kW

1.9 kW

COP Tj = 12°C

7.04

5.59

Cdh Tj = +12 °C

0.94

0.96

Pdh Tj = Tbiv

5.1 kW

4.6 kW

COP Tj = Tbiv

3.13

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.1 kW

4.6 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.13

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.991

0.994

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

1195 kWh

1506 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

132 %

Prated

5.1 kW

4.6 kW

SCOP

4.75

3.39

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.5 kW

4.1 kW

COP Tj = -7°C

2.92

2.04

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.7 kW

2.5 kW

COP Tj = +2°C

4.58

3.25

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

2.6 kW

2.6 kW

COP Tj = +7°C

6.5

4.64

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

2.6 kW

2.3 kW

COP Tj = 12°C

8.97

6.57

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

4.5 kW

4.1 kW

COP Tj = Tbiv

2.92

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.36 kW

4.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.91

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.991

0.993

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.74 kW

0.55 kW

Annual energy consumption Qhe

2220 kWh

2806 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

167 %

COP

4

Heating up time

02:00 h:min

Standby power input

23 W

Reference hot water temperature

55.5 °C

Mixed water at 40°C

236 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

148 %

COP

3.55

Heating up time

02:25 h:min

Standby power input

26 W

Reference hot water temperature

55.5 °C

Mixed water at 40°C

236 l

SUZ-SWM40VA + ERST17D-*M*BD
Configure model
Model name
SUZ-SWM40VA + ERST17D-*M*BD
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4 kW

4.5 kW

El input

0.77 kW

1.72 kW

COP

5.2

2.61

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

225 %

160 %

Prated

5.1 kW

4.6 kW

SCOP

5.7

4.08

Tbiv

2 °C

2 °C

TOL

-20 °C

-20 °C

Pdh Tj = +2°C

5.1 kW

4.6 kW

COP Tj = +2°C

3.13

1.85

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.3 kW

3 kW

COP Tj = +7°C

5.18

3.45

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

1.9 kW

1.9 kW

COP Tj = 12°C

7.04

5.59

Cdh Tj = +12 °C

0.94

0.96

Pdh Tj = Tbiv

5.1 kW

4.6 kW

COP Tj = Tbiv

3.13

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.1 kW

4.6 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.13

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.991

0.994

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

1195 kWh

1506 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

132 %

Prated

5.1 kW

4.6 kW

SCOP

4.75

3.39

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

4.5 kW

4.1 kW

COP Tj = -7°C

2.92

2.04

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.7 kW

2.5 kW

COP Tj = +2°C

4.58

3.25

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

2.6 kW

2.6 kW

COP Tj = +7°C

6.5

4.64

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

2.6 kW

2.3 kW

COP Tj = 12°C

8.97

6.57

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

4.5 kW

4.1 kW

COP Tj = Tbiv

2.92

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.36 kW

4.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.91

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.991

0.993

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.74 kW

0.55 kW

Annual energy consumption Qhe

2220 kWh

2806 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

167 %

COP

4

Heating up time

02:00 h:min

Standby power input

23 W

Reference hot water temperature

55.5 °C

Mixed water at 40°C

236 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

148 %

COP

3.55

Heating up time

02:25 h:min

Standby power input

26 W

Reference hot water temperature

55.5 °C

Mixed water at 40°C

236 l