Certificate holders

Subtype

AA packaged 11

Certificate Holder
Mitsubishi Electric Air Conditioning Systems Europe LTD
Nettlehill Road, Houston Industrial Estate
EH54 5EQ Livingston
United Kingdom
Registration number
037-0002-18
Certification Body
SZU - Strojirensky zkusebni ustav (Engineering Test Institute, Public Enterprise)
Subtype title
AA packaged 11
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

3,300 kg

Certification Date
09.10.2018
Testing basis
HP Keymark scheme rules rev. no. 4
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

PUHZ-W112VAA
Configure model
Model name
PUHZ-W112VAA
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

11.20 kW

El input

2.47 kW

4.15 kW

COP

4.54

2.70

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

174 %

135 %

Prated

10.00 kW

10.00 kW

SCOP

4.41

3.44

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

8.90 kW

9.00 kW

COP Tj = -7°C

3.17

1.99

Cdh Tj = -7 °C

0.995

0.997

Pdh Tj = +2°C

5.40 kW

5.70 kW

COP Tj = +2°C

4.23

3.30

Cdh Tj = +2 °C

0.988

0.991

Pdh Tj = +7°C

3.60 kW

4.70 kW

COP Tj = +7°C

5.33

4.86

Cdh Tj = +7 °C

0.978

0.984

Pdh Tj = 12°C

4.30 kW

4.10 kW

COP Tj = 12°C

7.66

6.35

Cdh Tj = +12 °C

0.973

0.977

Pdh Tj = Tbiv

8.90 kW

9.00 kW

COP Tj = Tbiv

3.17

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.35 kW

8.42 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

1.87

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.970

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.65 kW

1.58 kW

Annual energy consumption Qhe

4681 kWh

5998 kWh

PUHZ-W112YAA
Configure model
Model name
PUHZ-W112YAA
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

11.20 kW

El input

2.47 kW

4.15 kW

COP

4.54

2.70

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

173 %

134 %

Prated

10.00 kW

10.00 kW

SCOP

4.40

3.44

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

8.90 kW

9.00 kW

COP Tj = -7°C

3.17

1.99

Cdh Tj = -7 °C

0.992

0.995

Pdh Tj = +2°C

5.40 kW

5.70 kW

COP Tj = +2°C

4.23

3.29

Cdh Tj = +2 °C

0.983

0.987

Pdh Tj = +7°C

3.60 kW

4.70 kW

COP Tj = +7°C

5.31

4.88

Cdh Tj = +7 °C

0.968

0.977

Pdh Tj = 12°C

4.30 kW

4.10 kW

COP Tj = 12°C

7.66

6.35

Cdh Tj = +12 °C

0.961

0.966

Pdh Tj = Tbiv

8.90 kW

9.00 kW

COP Tj = Tbiv

3.17

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.35 kW

8.42 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

1.87

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.950

0.960

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.65 kW

1.58 kW

Annual energy consumption Qhe

4693 kWh

6012 kWh