2,400 kg
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
6.00 kW
6.00 kW
El input
1.24 kW
2.09 kW
COP
4.83
2.87
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
188 %
132 %
Prated
6.00 kW
6.00 kW
SCOP
4.77
3.37
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
5.30 kW
5.30 kW
COP Tj = -7°C
3.18
2.09
Cdh Tj = -7 °C
0.991
0.994
Pdh Tj = +2°C
3.20 kW
3.20 kW
COP Tj = +2°C
4.52
3.22
Cdh Tj = +2 °C
0.979
0.985
Pdh Tj = +7°C
3.20 kW
2.90 kW
COP Tj = +7°C
6.55
4.62
Cdh Tj = +7 °C
0.969
0.976
Pdh Tj = 12°C
2.90 kW
2.70 kW
COP Tj = 12°C
8.16
6.09
Cdh Tj = +12 °C
0.958
0.966
Pdh Tj = Tbiv
5.30 kW
5.30 kW
COP Tj = Tbiv
3.18
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.88 kW
4.88 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
1.90
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.950
0.960
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.12 kW
1.12 kW
Annual energy consumption Qhe
2598 kWh
3674 kWh
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
9.00 kW
9.00 kW
El input
2.00 kW
3.24 kW
COP
4.51
2.78
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
139 %
Prated
8.50 kW
8.50 kW
SCOP
4.44
3.56
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
7.50 kW
7.50 kW
COP Tj = -7°C
2.21
1.96
Cdh Tj = -7 °C
0.996
0.996
Pdh Tj = +2°C
4.60 kW
4.60 kW
COP Tj = +2°C
4.53
3.50
Cdh Tj = +2 °C
0.985
0.989
Pdh Tj = +7°C
3.40 kW
2.90 kW
COP Tj = +7°C
6.28
4.90
Cdh Tj = +7 °C
0.972
0.975
Pdh Tj = 12°C
3.20 kW
2.90 kW
COP Tj = 12°C
8.48
6.80
Cdh Tj = +12 °C
0.960
0.965
Pdh Tj = Tbiv
7.50 kW
7.50 kW
COP Tj = Tbiv
2.21
1.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.65 kW
6.65 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.00
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.950
0.960
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.85 kW
1.85 kW
Annual energy consumption Qhe
3952 kWh
4933 kWh
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
9.00 kW
9.00 kW
El input
2.00 kW
3.24 kW
COP
4.51
2.78
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
174 %
139 %
Prated
8.50 kW
8.50 kW
SCOP
4.43
3.55
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
7.50 kW
7.50 kW
COP Tj = -7°C
2.21
1.96
Cdh Tj = -7 °C
0.994
0.994
Pdh Tj = +2°C
4.60 kW
4.60 kW
COP Tj = +2°C
4.53
3.50
Cdh Tj = +2 °C
0.978
0.983
Pdh Tj = +7°C
3.40 kW
2.90 kW
COP Tj = +7°C
6.28
4.90
Cdh Tj = +7 °C
0.959
0.963
Pdh Tj = 12°C
3.20 kW
2.90 kW
COP Tj = 12°C
8.48
6.80
Cdh Tj = +12 °C
0.942
0.948
Pdh Tj = Tbiv
7.50 kW
7.50 kW
COP Tj = Tbiv
2.21
1.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.65 kW
6.65 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.99
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.930
0.940
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.85 kW
1.85 kW
Annual energy consumption Qhe
3962 kWh
4941 kWh