CTC EcoAir 420

Certificate Holder
CTC AB
Box 309, Näsvägen
SE-341 26 Ljungby
Sweden
Registration number
012-060 / Issue 2
Certification Body
RISE CERT
Subtype title
CTC EcoAir 420
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R407c
Mass of Refrigerant

3,500 kg

Certification Date
n/a
Testing basis
EN 14511:2013, EN 14825:2013, EN12102:2013
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

CTC EcoAir 420 3x400V
Configure model
Model name
CTC EcoAir 420 3x400V
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

18.72 kW

15.94 kW

El input

4.05 kW

5.45 kW

COP

4.62

2.92

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

129 %

107 %

Prated

11.91 kW

11.14 kW

SCOP

3.30

2.80

Tbiv

-14 °C

-14 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

11.60 kW

11.00 kW

COP Tj = -7°C

3.20

2.52

Pdh Tj = +2°C

14.10 kW

13.60 kW

COP Tj = +2°C

3.84

3.15

Pdh Tj = +7°C

17.80 kW

17.40 kW

COP Tj = +7°C

4.74

4.01

Pdh Tj = 12°C

21.30 kW

20.50 kW

COP Tj = 12°C

5.54

4.76

Pdh Tj = Tbiv

9.10 kW

8.50 kW

COP Tj = Tbiv

2.63

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.80 kW

6.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.04

1.44

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

65 °C

65 °C

Poff

18 W

18 W

PTO

68 W

20 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.00 kW

4.90 kW

Annual energy consumption Qhe

8876 kWh

9970 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

145 %

119 %

Prated

13.88 kW

14.20 kW

SCOP

3.70

3.10

Tbiv

-6 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

10.90 kW

COP Tj = -7°C

3.07

2.35

Pdh Tj = +2°C

14.00 kW

13.40 kW

COP Tj = +2°C

3.72

2.97

Pdh Tj = +7°C

17.70 kW

17.30 kW

COP Tj = +7°C

4.64

3.81

Pdh Tj = 12°C

21.40 kW

20.30 kW

COP Tj = 12°C

5.56

4.62

Pdh Tj = Tbiv

11.50 kW

11.50 kW

COP Tj = Tbiv

3.15

2.49

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.50 kW

10.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

65 °C

65 °C

Poff

18 W

18 W

PTO

68 W

20 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.40 kW

4.30 kW

Annual energy consumption Qhe

7739 kWh

9646 kWh