Certificate holders

Subtype

Samsung EHS R32 Mono 8kW (space heating/ 200L)

Certificate Holder
Samsung Electronics Air Conditioner Europe B.V.
Evert van de Beekstraat 310
1118 CX Schiphol
Netherlands
Reg. No.
007-CU0102
Certification Body
Kiwa Nederland B.V.
Name of testing laboratory
Kiwa Nederland B.V.
Subtype title
Samsung EHS R32 Mono 8kW (space heating/ 200L)
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
HFC-32
Mass Of Refrigerant

1,150 kg

Certification Date
29.11.2019
Testing basis
n/a
Generate PDF Export model CSV Download certificate

Models

AE080RXYDEG/EU & AE200RNWMEG/EU
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

7.10 kW

El input

1.77 kW

2.53 kW

COP

4.52

2.81

Indoor water flow rate

1.39 m³/h

0.77 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

126 %

Prated

8.00 kW

8.00 kW

SCOP

4.44

3.23

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.08 kW

7.08 kW

COP Tj = -7°C

2.63

1.90

Cdh

0.90

0.90

Pdh Tj = +2°C

4.31 kW

4.31 kW

COP Tj = +2°C

4.24

3.11

Cdh

0.90

0.90

Pdh Tj = +7°C

3.10 kW

2.80 kW

COP Tj = +7°C

6.39

4.55

Cdh

0.90

0.90

Pdh Tj = 12°C

2.60 kW

2.40 kW

COP Tj = 12°C

8.22

5.77

Cdh

0.90

0.90

Pdh Tj = Tbiv

7.10 kW

7.10 kW

COP Tj = Tbiv

2.63

1.90

Pdh Tj = TOL

7.00 kW

6.80 kW

COP Tj = TOL

2.48

1.66

WTOL

65 °C

65 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electrical

Electrical

Supplementary Heater: PSUP

2.00 kW

2.00 kW

Annual energy consumption Qhe

3719 kWh

5113 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

115 %

COP

2.85

Heating up time

2:00 h:min

Standby power input

60.0 W

Reference hot water temperature

52.1 °C

Mixed water at 40°C

225 l

AE080RXYDEG/EU & MIM-E03CN
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

7.10 kW

El input

1.77 kW

2.53 kW

COP

4.52

2.81

Indoor water flow rate

1.39 m³/h

0.77 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

126 %

Prated

8.00 kW

8.00 kW

SCOP

4.44

3.23

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.08 kW

7.08 kW

COP Tj = -7°C

2.63

1.90

Cdh

0.90

0.90

Pdh Tj = +2°C

4.31 kW

4.31 kW

COP Tj = +2°C

4.24

3.11

Cdh

0.90

0.90

Pdh Tj = +7°C

3.10 kW

2.80 kW

COP Tj = +7°C

6.39

4.55

Cdh

0.90

0.90

Pdh Tj = 12°C

2.60 kW

2.40 kW

COP Tj = 12°C

8.22

5.77

Cdh

0.90

0.90

Pdh Tj = Tbiv

7.10 kW

7.10 kW

COP Tj = Tbiv

2.63

1.90

Pdh Tj = TOL

7.00 kW

6.80 kW

COP Tj = TOL

2.48

1.66

WTOL

65 °C

65 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electrical

Electrical

Supplementary Heater: PSUP

2.00 kW

2.00 kW

Annual energy consumption Qhe

3719 kWh

5113 kWh