Certificate holders

Subtype

LW 101

Certificate Holder
ait-deutschland GmbH
Industriestr. 3
95359 Kasendorf
Germany
Registration number
041-K001-36 / 1
Certification Body
BRE Global Limited
Subtype title
LW 101
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R407c
Mass of Refrigerant

4,800 kg

Certification Date
08.10.2019
Testing basis
n/a
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

LW 101
Configure model
Model name
LW 101
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.40 kW

10.27 kW

El input

2.49 kW

3.71 kW

COP

4.18

2.64

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

149 %

121 %

Prated

9.90 kW

9.35 kW

SCOP

3.81

3.11

Tbiv

-5 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.53 kW

6.98 kW

COP Tj = -7°C

2.97

2.03

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

9.54 kW

9.41 kW

COP Tj = +2°C

3.78

3.11

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

10.43 kW

10.40 kW

COP Tj = +7°C

4.69

4.04

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

12.19 kW

12.17 kW

COP Tj = 12°C

5.15

5.02

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

8.00 kW

7.55 kW

COP Tj = Tbiv

3.19

2.25

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.84 kW

6.27 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.70

1.79

WTOL

65 °C

65 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.06 kW

3.08 kW

Annual energy consumption Qhe

5367 kWh

6216 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

179 %

145 %

Prated

11.53 kW

11.30 kW

SCOP

4.56

3.71

Tbiv

4 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.50 kW

9.23 kW

COP Tj = +2°C

3.56

2.52

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

10.42 kW

10.33 kW

COP Tj = +7°C

4.46

3.27

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

12.17 kW

12.10 kW

COP Tj = 12°C

5.08

4.61

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

9.88 kW

9.68 kW

COP Tj = Tbiv

3.94

2.78

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.50 kW

9.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.56

2.52

WTOL

65 °C

65 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.03 kW

2.07 kW

Annual energy consumption Qhe

3376 kWh

4069 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

132 %

108 %

Prated

8.82 kW

8.22 kW

SCOP

3.38

2.77

Tbiv

-12 °C

-12 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

7.62 kW

7.23 kW

COP Tj = -7°C

3.18

2.37

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

9.57 kW

9.48 kW

COP Tj = +2°C

3.92

3.40

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

10.44 kW

10.42 kW

COP Tj = +7°C

4.83

4.44

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

12.18 kW

12.20 kW

COP Tj = 12°C

5.00

5.18

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

6.50 kW

6.06 kW

COP Tj = Tbiv

2.77

1.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.66 kW

4.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.99

1.34

WTOL

65 °C

65 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

8.82 kW

8.22 kW

Annual energy consumption Qhe

6437 kWh

7306 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.80

5.37

COP Tj = -15°C (if TOL<-20°C)

2.47

1.72

Cdh Tj = -15 °C

1.00

1.00

LW 101A
Configure model
Model name
LW 101A
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.40 kW

10.27 kW

El input

2.49 kW

3.71 kW

COP

4.18

2.64

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

149 %

121 %

Prated

9.90 kW

9.35 kW

SCOP

3.81

3.11

Tbiv

-5 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.53 kW

6.98 kW

COP Tj = -7°C

2.97

2.03

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

9.54 kW

9.41 kW

COP Tj = +2°C

3.78

3.11

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

10.43 kW

10.40 kW

COP Tj = +7°C

4.69

4.04

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

12.19 kW

12.17 kW

COP Tj = 12°C

5.15

5.02

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

8.00 kW

7.55 kW

COP Tj = Tbiv

3.19

2.25

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.84 kW

6.27 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.70

1.79

WTOL

65 °C

65 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.06 kW

3.08 kW

Annual energy consumption Qhe

5367 kWh

6216 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

179 %

145 %

Prated

11.53 kW

11.30 kW

SCOP

4.56

3.71

Tbiv

4 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

9.50 kW

9.23 kW

COP Tj = +2°C

3.56

2.52

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

10.42 kW

10.33 kW

COP Tj = +7°C

4.46

3.27

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

12.17 kW

12.10 kW

COP Tj = 12°C

5.08

4.61

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

9.88 kW

9.68 kW

COP Tj = Tbiv

3.94

2.78

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.50 kW

9.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.56

2.52

WTOL

65 °C

65 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.03 kW

2.07 kW

Annual energy consumption Qhe

3376 kWh

4069 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

132 %

108 %

Prated

8.82 kW

8.22 kW

SCOP

3.38

2.77

Tbiv

-12 °C

-12 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

7.62 kW

7.23 kW

COP Tj = -7°C

3.18

2.37

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

9.57 kW

9.48 kW

COP Tj = +2°C

3.92

3.40

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

10.44 kW

10.42 kW

COP Tj = +7°C

4.83

4.44

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

12.18 kW

12.20 kW

COP Tj = 12°C

5.00

5.18

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

6.50 kW

6.06 kW

COP Tj = Tbiv

2.77

1.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.66 kW

4.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.99

1.34

WTOL

65 °C

65 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

8.82 kW

8.22 kW

Annual energy consumption Qhe

6437 kWh

7306 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.80

5.37

COP Tj = -15°C (if TOL<-20°C)

2.47

1.72

Cdh Tj = -15 °C

1.00

1.00