Certificate holders

Subtype

LWC 100

Certificate Holder
ait-deutschland GmbH
Industriestr. 3
95359 Kasendorf
Germany
Registration number
041-K001-29 / 1
Certification Body
BRE Global Limited
Subtype title
LWC 100
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R404A
Mass of Refrigerant

4,100 kg

Certification Date
06.09.2019
Testing basis
n/a
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

LWC 100
Configure model
Model name
LWC 100
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.20 kW

11.20 kW

El input

2.98 kW

5.01 kW

COP

4.10

2.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

146 %

116 %

Prated

11.89 kW

11.19 kW

SCOP

3.73

2.97

Tbiv

-4 °C

-4 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.43 kW

7.83 kW

COP Tj = -7°C

2.86

2.01

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

10.51 kW

10.17 kW

COP Tj = +2°C

3.77

2.93

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

12.41 kW

12.15 kW

COP Tj = +7°C

4.63

3.93

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

14.06 kW

14.00 kW

COP Tj = 12°C

5.03

4.88

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

9.14 kW

8.61 kW

COP Tj = Tbiv

3.19

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.69 kW

7.17 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.79

WTOL

58 °C

58 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.20 kW

4.02 kW

Annual energy consumption Qhe

6587 kWh

7791 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

175 %

137 %

Prated

13.05 kW

12.23 kW

SCOP

4.45

3.51

Tbiv

4 °C

4 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.40 kW

9.73 kW

COP Tj = +2°C

3.47

2.25

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

12.31 kW

11.69 kW

COP Tj = +7°C

4.35

3.07

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

13.99 kW

13.76 kW

COP Tj = 12°C

4.92

4.43

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

11.18 kW

10.49 kW

COP Tj = Tbiv

3.87

2.53

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.40 kW

9.73 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.47

2.25

WTOL

58 °C

58 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.65 kW

2.50 kW

Annual energy consumption Qhe

3920 kWh

4652 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

131 %

107 %

Prated

9.21 kW

8.82 kW

SCOP

3.34

2.74

Tbiv

-13 °C

-13 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

8.53 kW

8.10 kW

COP Tj = -7°C

3.04

2.32

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

10.57 kW

10.33 kW

COP Tj = +2°C

3.94

3.28

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

12.47 kW

12.34 kW

COP Tj = +7°C

4.75

4.36

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

14.04 kW

14.12 kW

COP Tj = 12°C

4.86

5.04

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

7.03 kW

6.73 kW

COP Tj = Tbiv

2.54

1.87

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.31 kW

5.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.89

1.42

WTOL

58 °C

58 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.21 kW

8.82 kW

Annual energy consumption Qhe

6791 kWh

7942 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.53

6.30

COP Tj = -15°C (if TOL<-20°C)

2.35

1.73

Cdh Tj = -15 °C

1.00

1.00