Certificate holders

Subtype

Ecodan Power Inverter 8

Certificate Holder
Mitsubishi Electric Europe B.V.
Mitsubishi-Electric-Platz 1
40882 Ratingen
Germany
Reg. No.
011-1W0107
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Name of testing laboratory
CETIAT
Subtype title
Ecodan Power Inverter 8
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
HFC-410a
Mass Of Refrigerant

3,200 kg

Certification Date
27.06.2017
Testing basis
n/a
Generate PDF Export model CSV

Models

PUHZ-SW75VHA(-BS) & EHSD-M*C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

8.00 kW

El input

1.82 kW

2.98 kW

COP

4.40

2.68

Indoor water flow rate

1.38 m³/h

0.86 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

127 %

Prated

7.20 kW

7.10 kW

SCOP

4.17

3.26

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

6.40 kW

6.30 kW

COP Tj = -7°C

2.89

1.95

Cdh

0.97

0.97

Pdh Tj = +2°C

3.90 kW

3.80 kW

COP Tj = +2°C

4.02

3.23

Cdh

0.97

0.97

Pdh Tj = +7°C

3.90 kW

3.70 kW

COP Tj = +7°C

5.57

4.49

Cdh

0.97

0.97

Pdh Tj = 12°C

4.60 kW

4.30 kW

COP Tj = 12°C

7.50

5.89

Cdh

0.97

0.97

Pdh Tj = Tbiv

6.40 kW

6.30 kW

COP Tj = Tbiv

2.98

1.95

Pdh Tj = TOL

6.00 kW

6.00 kW

COP Tj = TOL

1.28

1.35

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electricity

electricity

Supplementary Heater: PSUP

0.90 kW

0.90 kW

Annual energy consumption Qhe

3475 kWh

4403 kWh

PUHZ-SW75VHA(-BS) & EHSD-VM*C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

8.00 kW

El input

1.82 kW

2.98 kW

COP

4.40

2.68

Indoor water flow rate

1.38 m³/h

0.86 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

127 %

Prated

7.20 kW

7.10 kW

SCOP

4.17

3.26

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

6.40 kW

6.30 kW

COP Tj = -7°C

2.89

1.95

Cdh

0.97

0.97

Pdh Tj = +2°C

3.90 kW

3.80 kW

COP Tj = +2°C

4.02

3.23

Cdh

0.97

0.97

Pdh Tj = +7°C

3.90 kW

3.70 kW

COP Tj = +7°C

5.57

4.49

Cdh

0.97

0.97

Pdh Tj = 12°C

4.60 kW

4.30 kW

COP Tj = 12°C

7.50

5.89

Cdh

0.97

0.97

Pdh Tj = Tbiv

6.40 kW

6.30 kW

COP Tj = Tbiv

2.98

1.95

Pdh Tj = TOL

6.00 kW

6.00 kW

COP Tj = TOL

1.28

1.35

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electricity

electricity

Supplementary Heater: PSUP

0.90 kW

0.90 kW

Annual energy consumption Qhe

3475 kWh

4403 kWh

PUHZ-SW75VHA(-BS) & EHSD-YM*C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

8.00 kW

El input

1.82 kW

2.98 kW

COP

4.40

2.68

Indoor water flow rate

1.38 m³/h

0.86 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

127 %

Prated

7.20 kW

7.10 kW

SCOP

4.17

3.26

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

6.40 kW

6.30 kW

COP Tj = -7°C

2.89

1.95

Cdh

0.97

0.97

Pdh Tj = +2°C

3.90 kW

3.80 kW

COP Tj = +2°C

4.02

3.23

Cdh

0.97

0.97

Pdh Tj = +7°C

3.90 kW

3.70 kW

COP Tj = +7°C

5.57

4.49

Cdh

0.97

0.97

Pdh Tj = 12°C

4.60 kW

4.30 kW

COP Tj = 12°C

7.50

5.89

Cdh

0.97

0.97

Pdh Tj = Tbiv

6.40 kW

6.30 kW

COP Tj = Tbiv

2.98

1.95

Pdh Tj = TOL

6.00 kW

6.00 kW

COP Tj = TOL

1.28

1.35

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electricity

electricity

Supplementary Heater: PSUP

0.90 kW

0.90 kW

Annual energy consumption Qhe

3475 kWh

4403 kWh

PUHZ-SW75VHA(-BS) & EHST20D-M*C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

8.00 kW

El input

n/a

2.98 kW

COP

n/a

2.68

Indoor water flow rate

n/a

0.86 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level indoor

n/a

40 dB(A)

Sound power level outdoor

n/a

68 dB(A)

EN 14825

Medium temperature

ηs

n/a

127 %

Prated

n/a

7.10 kW

SCOP

n/a

3.26

Tbiv

n/a

-7 °C

TOL

n/a

-20 °C

Pdh Tj = -7°C

n/a

6.30 kW

COP Tj = -7°C

n/a

1.95

Cdh

n/a

0.97

Pdh Tj = +2°C

n/a

3.80 kW

COP Tj = +2°C

n/a

3.23

Cdh

n/a

0.97

Pdh Tj = +7°C

n/a

3.70 kW

COP Tj = +7°C

n/a

4.49

Cdh

n/a

0.97

Pdh Tj = 12°C

n/a

4.30 kW

COP Tj = 12°C

n/a

5.89

Cdh

n/a

0.97

Pdh Tj = Tbiv

n/a

6.30 kW

COP Tj = Tbiv

n/a

1.95

Pdh Tj = TOL

n/a

6.00 kW

COP Tj = TOL

n/a

1.35

WTOL

n/a

60 °C

Poff

n/a

15 W

PTO

n/a

15 W

PSB

n/a

15 W

PCK

n/a

0 W

Supplementary Heater: Type of energy input

n/a

electricity

Supplementary Heater: PSUP

n/a

0.90 kW

Annual energy consumption Qhe

n/a

4403 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

105 %

COP

2.46

Heating up time

2:15 h:min

Standby power input

41.0 W

Reference hot water temperature

51.8 °C

Mixed water at 40°C

278 l

PUHZ-SW75VHA(-BS) & EHST20D-VM*C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

8.00 kW

El input

n/a

2.98 kW

COP

n/a

2.68

Indoor water flow rate

n/a

0.86 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level indoor

n/a

40 dB(A)

Sound power level outdoor

n/a

68 dB(A)

EN 14825

Medium temperature

ηs

n/a

127 %

Prated

n/a

7.10 kW

SCOP

n/a

3.26

Tbiv

n/a

-7 °C

TOL

n/a

-20 °C

Pdh Tj = -7°C

n/a

6.30 kW

COP Tj = -7°C

n/a

1.95

Cdh

n/a

0.97

Pdh Tj = +2°C

n/a

3.80 kW

COP Tj = +2°C

n/a

3.23

Cdh

n/a

0.97

Pdh Tj = +7°C

n/a

3.70 kW

COP Tj = +7°C

n/a

4.49

Cdh

n/a

0.97

Pdh Tj = 12°C

n/a

4.30 kW

COP Tj = 12°C

n/a

5.89

Cdh

n/a

0.97

Pdh Tj = Tbiv

n/a

6.30 kW

COP Tj = Tbiv

n/a

1.95

Pdh Tj = TOL

n/a

6.00 kW

COP Tj = TOL

n/a

1.35

WTOL

n/a

60 °C

Poff

n/a

15 W

PTO

n/a

15 W

PSB

n/a

15 W

PCK

n/a

0 W

Supplementary Heater: Type of energy input

n/a

electricity

Supplementary Heater: PSUP

n/a

0.90 kW

Annual energy consumption Qhe

n/a

4403 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

105 %

COP

2.46

Heating up time

2:15 h:min

Standby power input

41.0 W

Reference hot water temperature

51.8 °C

Mixed water at 40°C

278 l

PUHZ-SW75VHA(-BS) & EHST20D-YM*C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

8.00 kW

El input

n/a

2.98 kW

COP

n/a

2.68

Indoor water flow rate

n/a

0.86 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level indoor

n/a

40 dB(A)

Sound power level outdoor

n/a

68 dB(A)

EN 14825

Medium temperature

ηs

n/a

127 %

Prated

n/a

7.10 kW

SCOP

n/a

3.26

Tbiv

n/a

-7 °C

TOL

n/a

-20 °C

Pdh Tj = -7°C

n/a

6.30 kW

COP Tj = -7°C

n/a

1.95

Cdh

n/a

0.97

Pdh Tj = +2°C

n/a

3.80 kW

COP Tj = +2°C

n/a

3.23

Cdh

n/a

0.97

Pdh Tj = +7°C

n/a

3.70 kW

COP Tj = +7°C

n/a

4.49

Cdh

n/a

0.97

Pdh Tj = 12°C

n/a

4.30 kW

COP Tj = 12°C

n/a

5.89

Cdh

n/a

0.97

Pdh Tj = Tbiv

n/a

6.30 kW

COP Tj = Tbiv

n/a

1.95

Pdh Tj = TOL

n/a

6.00 kW

COP Tj = TOL

n/a

1.35

WTOL

n/a

60 °C

Poff

n/a

15 W

PTO

n/a

15 W

PSB

n/a

15 W

PCK

n/a

0 W

Supplementary Heater: Type of energy input

n/a

electricity

Supplementary Heater: PSUP

n/a

0.90 kW

Annual energy consumption Qhe

n/a

4403 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

105 %

COP

2.46

Heating up time

2:15 h:min

Standby power input

41.0 W

Reference hot water temperature

51.8 °C

Mixed water at 40°C

278 l

PUHZ-SW75VHA(-BS) & ERSD-VM*C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

8.00 kW

El input

1.82 kW

2.98 kW

COP

4.40

2.68

Indoor water flow rate

1.38 m³/h

0.86 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

68 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

129 %

Prated

7.20 kW

7.10 kW

SCOP

4.24

3.30

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

6.40 kW

6.30 kW

COP Tj = -7°C

2.89

1.95

Cdh

0.97

0.97

Pdh Tj = +2°C

3.90 kW

3.80 kW

COP Tj = +2°C

4.02

3.23

Cdh

0.97

0.97

Pdh Tj = +7°C

3.90 kW

3.70 kW

COP Tj = +7°C

5.57

4.49

Cdh

0.97

0.97

Pdh Tj = 12°C

4.60 kW

4.30 kW

COP Tj = 12°C

7.50

5.89

Cdh

0.97

0.97

Pdh Tj = Tbiv

6.40 kW

6.30 kW

COP Tj = Tbiv

2.98

1.95

Pdh Tj = TOL

6.00 kW

6.00 kW

COP Tj = TOL

1.28

1.35

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electricity

electricity

Supplementary Heater: PSUP

0.90 kW

0.90 kW

Annual energy consumption Qhe

3475 kWh

4403 kWh

PUHZ-SW75VHA(-BS) & ERST20D-M*C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

8.00 kW

El input

n/a

2.98 kW

COP

n/a

2.68

Indoor water flow rate

n/a

0.86 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level indoor

n/a

40 dB(A)

Sound power level outdoor

n/a

68 dB(A)

EN 14825

Medium temperature

ηs

n/a

129 %

Prated

n/a

7.10 kW

SCOP

n/a

3.30

Tbiv

n/a

-7 °C

TOL

n/a

-20 °C

Pdh Tj = -7°C

n/a

6.30 kW

COP Tj = -7°C

n/a

1.95

Cdh

n/a

0.97

Pdh Tj = +2°C

n/a

3.80 kW

COP Tj = +2°C

n/a

3.23

Cdh

n/a

0.97

Pdh Tj = +7°C

n/a

3.70 kW

COP Tj = +7°C

n/a

4.49

Cdh

n/a

0.97

Pdh Tj = 12°C

n/a

4.30 kW

COP Tj = 12°C

n/a

5.89

Cdh

n/a

0.97

Pdh Tj = Tbiv

n/a

6.30 kW

COP Tj = Tbiv

n/a

1.95

Pdh Tj = TOL

n/a

6.00 kW

COP Tj = TOL

n/a

1.35

WTOL

n/a

60 °C

Poff

n/a

15 W

PTO

n/a

15 W

PSB

n/a

15 W

PCK

n/a

0 W

Supplementary Heater: Type of energy input

n/a

electricity

Supplementary Heater: PSUP

n/a

0.90 kW

Annual energy consumption Qhe

n/a

4403 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

105 %

COP

2.46

Heating up time

2:15 h:min

Standby power input

41.0 W

Reference hot water temperature

51.8 °C

Mixed water at 40°C

278 l

PUHZ-SW75VHA(-BS) & ERST20D-VM*C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

8.00 kW

El input

n/a

2.98 kW

COP

n/a

2.68

Indoor water flow rate

n/a

0.86 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level indoor

n/a

40 dB(A)

Sound power level outdoor

n/a

68 dB(A)

EN 14825

Medium temperature

ηs

n/a

129 %

Prated

n/a

7.10 kW

SCOP

n/a

3.30

Tbiv

n/a

-7 °C

TOL

n/a

-20 °C

Pdh Tj = -7°C

n/a

6.30 kW

COP Tj = -7°C

n/a

1.95

Cdh

n/a

0.97

Pdh Tj = +2°C

n/a

3.80 kW

COP Tj = +2°C

n/a

3.23

Cdh

n/a

0.97

Pdh Tj = +7°C

n/a

3.70 kW

COP Tj = +7°C

n/a

4.49

Cdh

n/a

0.97

Pdh Tj = 12°C

n/a

4.30 kW

COP Tj = 12°C

n/a

5.89

Cdh

n/a

0.97

Pdh Tj = Tbiv

n/a

6.30 kW

COP Tj = Tbiv

n/a

1.95

Pdh Tj = TOL

n/a

6.00 kW

COP Tj = TOL

n/a

1.35

WTOL

n/a

60 °C

Poff

n/a

15 W

PTO

n/a

15 W

PSB

n/a

15 W

PCK

n/a

0 W

Supplementary Heater: Type of energy input

n/a

electricity

Supplementary Heater: PSUP

n/a

0.90 kW

Annual energy consumption Qhe

n/a

4403 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

105 %

COP

2.46

Heating up time

2:15 h:min

Standby power input

41.0 W

Reference hot water temperature

51.8 °C

Mixed water at 40°C

278 l