Certificate holders

Subtype

WWC 160 H/X

Certificate Holder
ait-deutschland GmbH
Industriestr. 3
95359 Kasendorf
Germany
Registration number
041-K001-33 / 1
Certification Body
BRE Global Limited
Subtype title
WWC 160 H/X
Driving energy
n/a
Heat Pump Type
Water/Water
Refrigerant
R407c
Mass of Refrigerant

3,950 kg

Certification Date
06.09.2019
Testing basis
n/a
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

WWC 160H/X
Configure model
Model name
WWC 160H/X
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.60 kW

13.42 kW

El input

2.73 kW

3.90 kW

COP

5.35

3.44

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

221 %

167 %

Prated

14.60 kW

13.83 kW

SCOP

5.72

4.37

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.61 kW

13.53 kW

COP Tj = -7°C

5.39

3.61

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

14.71 kW

13.97 kW

COP Tj = +2°C

5.70

4.28

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

14.79 kW

14.50 kW

COP Tj = +7°C

5.97

4.92

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

14.87 kW

14.72 kW

COP Tj = 12°C

6.31

5.60

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

14.60 kW

13.35 kW

COP Tj = Tbiv

5.35

3.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.60 kW

13.35 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.35

3.40

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5278 kWh

6534 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

240 %

168 %

Prated

14.70 kW

13.83 kW

SCOP

6.19

4.40

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

14.70 kW

13.83 kW

COP Tj = +2°C

5.65

3.41

Cdh Tj = +2 °C

n/a

1.00

Pdh Tj = +7°C

14.79 kW

14.14 kW

COP Tj = +7°C

6.05

3.99

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

14.93 kW

14.58 kW

COP Tj = 12°C

6.68

5.14

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

14.70 kW

13.83 kW

COP Tj = Tbiv

5.65

3.41

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.70 kW

13.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.65

3.41

WTOL

65 °C

65 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3172 kWh

4197 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

246 %

172 %

Prated

14.70 kW

13.83 kW

SCOP

6.34

4.50

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

14.83 kW

14.22 kW

COP Tj = -7°C

6.21

4.16

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

14.91 kW

14.47 kW

COP Tj = +2°C

6.57

4.80

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

14.97 kW

14.65 kW

COP Tj = +7°C

6.84

5.39

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

14.98 kW

14.79 kW

COP Tj = 12°C

6.76

5.84

Cdh Tj = +12 °C

1.00

1.00

Pdh Tj = Tbiv

14.70 kW

13.83 kW

COP Tj = Tbiv

5.65

3.41

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.70 kW

13.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.65

3.41

WTOL

65 °C

65 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5716 kWh

7568 kWh

Pdh Tj = -15°C (if TOL<-20°C)

0.01

0.01

COP Tj = -15°C (if TOL<-20°C)

0.01

0.01

Cdh Tj = -15 °C

1.00

1.00