Certificate holders

Subtype

Ecodan Power Inverter 10

Certificate Holder
Mitsubishi Electric Europe B.V.
Mitsubishi-Electric-Platz 1
40882 Ratingen
Germany
Reg. No.
011-1W0108
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Name of testing laboratory
CETIAT
Subtype title
Ecodan Power Inverter 10
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
HFC-410a
Mass Of Refrigerant

4,600 kg

Certification Date
27.06.2017
Testing basis
n/a
Generate PDF Export model CSV

Models

PUHZ-SW100VHA(-BS) & EHSC-M*C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

11.20 kW

El input

2.52 kW

4.46 kW

COP

4.44

2.51

Indoor water flow rate

1.93 m³/h

1.20 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

164 %

125 %

Prated

10.40 kW

10.00 kW

SCOP

4.16

3.20

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

9.20 kW

8.90 kW

COP Tj = -7°C

2.47

1.79

Cdh

0.98

0.98

Pdh Tj = +2°C

5.60 kW

5.40 kW

COP Tj = +2°C

4.24

3.18

Cdh

0.98

0.98

Pdh Tj = +7°C

4.30 kW

3.90 kW

COP Tj = +7°C

5.49

4.37

Cdh

0.98

0.98

Pdh Tj = 12°C

7.30 kW

7.00 kW

COP Tj = 12°C

7.43

6.58

Cdh

0.98

0.98

Pdh Tj = Tbiv

9.20 kW

8.90 kW

COP Tj = Tbiv

2.47

1.79

Pdh Tj = TOL

6.50 kW

6.50 kW

COP Tj = TOL

1.40

1.33

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electricity

electricity

Supplementary Heater: PSUP

1.80 kW

1.70 kW

Annual energy consumption Qhe

5027 kWh

6331 kWh

PUHZ-SW100VHA(-BS) & EHSC-VM*C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

11.20 kW

El input

2.52 kW

4.46 kW

COP

4.44

2.51

Indoor water flow rate

1.93 m³/h

1.20 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

164 %

125 %

Prated

10.40 kW

10.00 kW

SCOP

4.16

3.20

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

9.20 kW

8.90 kW

COP Tj = -7°C

2.47

1.79

Cdh

0.98

0.98

Pdh Tj = +2°C

5.60 kW

5.40 kW

COP Tj = +2°C

4.24

3.18

Cdh

0.98

0.98

Pdh Tj = +7°C

4.30 kW

3.90 kW

COP Tj = +7°C

5.49

4.37

Cdh

0.98

0.98

Pdh Tj = 12°C

7.30 kW

7.00 kW

COP Tj = 12°C

7.43

6.58

Cdh

0.98

0.98

Pdh Tj = Tbiv

9.20 kW

8.90 kW

COP Tj = Tbiv

2.47

1.79

Pdh Tj = TOL

6.50 kW

6.50 kW

COP Tj = TOL

1.40

1.33

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electricity

electricity

Supplementary Heater: PSUP

1.80 kW

1.70 kW

Annual energy consumption Qhe

5027 kWh

6331 kWh

PUHZ-SW100VHA(-BS) & EHSC-YM*C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

11.20 kW

El input

2.52 kW

4.46 kW

COP

4.44

2.51

Indoor water flow rate

1.93 m³/h

1.20 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

164 %

125 %

Prated

10.40 kW

10.00 kW

SCOP

4.16

3.20

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

9.20 kW

8.90 kW

COP Tj = -7°C

2.47

1.79

Cdh

0.98

0.98

Pdh Tj = +2°C

5.60 kW

5.40 kW

COP Tj = +2°C

4.24

3.18

Cdh

0.98

0.98

Pdh Tj = +7°C

4.30 kW

3.90 kW

COP Tj = +7°C

5.49

4.37

Cdh

0.98

0.98

Pdh Tj = 12°C

7.30 kW

7.00 kW

COP Tj = 12°C

7.43

6.58

Cdh

0.98

0.98

Pdh Tj = Tbiv

9.20 kW

8.90 kW

COP Tj = Tbiv

2.47

1.79

Pdh Tj = TOL

6.50 kW

6.50 kW

COP Tj = TOL

1.40

1.33

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electricity

electricity

Supplementary Heater: PSUP

1.80 kW

1.70 kW

Annual energy consumption Qhe

5027 kWh

6331 kWh

PUHZ-SW100YHA(-BS) & EHSC-M*C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

11.20 kW

El input

2.52 kW

4.46 kW

COP

4.44

2.51

Indoor water flow rate

1.93 m³/h

1.20 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

164 %

125 %

Prated

10.40 kW

10.00 kW

SCOP

4.16

3.20

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

9.20 kW

8.90 kW

COP Tj = -7°C

2.47

1.79

Cdh

0.99

0.99

Pdh Tj = +2°C

5.60 kW

5.40 kW

COP Tj = +2°C

4.27

3.21

Cdh

0.99

0.99

Pdh Tj = +7°C

4.30 kW

3.90 kW

COP Tj = +7°C

5.54

4.39

Cdh

0.99

0.99

Pdh Tj = 12°C

7.30 kW

7.00 kW

COP Tj = 12°C

7.43

6.58

Cdh

0.99

0.99

Pdh Tj = Tbiv

9.20 kW

8.90 kW

COP Tj = Tbiv

2.47

1.79

Pdh Tj = TOL

6.50 kW

6.50 kW

COP Tj = TOL

1.33

1.40

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electricity

electricity

Supplementary Heater: PSUP

1.80 kW

1.70 kW

Annual energy consumption Qhe

4993 kWh

6288 kWh

PUHZ-SW100YHA(-BS) & EHSC-VM*C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

11.20 kW

El input

2.52 kW

4.46 kW

COP

4.44

2.51

Indoor water flow rate

1.93 m³/h

1.20 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

164 %

125 %

Prated

10.40 kW

10.00 kW

SCOP

4.16

3.20

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

9.20 kW

8.90 kW

COP Tj = -7°C

2.47

1.79

Cdh

0.99

0.99

Pdh Tj = +2°C

5.60 kW

5.40 kW

COP Tj = +2°C

4.27

3.21

Cdh

0.99

0.99

Pdh Tj = +7°C

4.30 kW

3.90 kW

COP Tj = +7°C

5.54

4.39

Cdh

0.99

0.99

Pdh Tj = 12°C

7.30 kW

7.00 kW

COP Tj = 12°C

7.43

6.58

Cdh

0.99

0.99

Pdh Tj = Tbiv

9.20 kW

8.90 kW

COP Tj = Tbiv

2.47

1.79

Pdh Tj = TOL

6.50 kW

6.50 kW

COP Tj = TOL

1.33

1.40

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electricity

electricity

Supplementary Heater: PSUP

1.80 kW

1.70 kW

Annual energy consumption Qhe

4993 kWh

6288 kWh

PUHZ-SW100YHA(-BS) & EHSC-YM*C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

11.20 kW

El input

2.52 kW

4.46 kW

COP

4.44

2.51

Indoor water flow rate

1.93 m³/h

1.20 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

164 %

125 %

Prated

10.40 kW

10.00 kW

SCOP

4.16

3.20

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

9.20 kW

8.90 kW

COP Tj = -7°C

2.47

1.79

Cdh

0.99

0.99

Pdh Tj = +2°C

5.60 kW

5.40 kW

COP Tj = +2°C

4.27

3.21

Cdh

0.99

0.99

Pdh Tj = +7°C

4.30 kW

3.90 kW

COP Tj = +7°C

5.54

4.39

Cdh

0.99

0.99

Pdh Tj = 12°C

7.30 kW

7.00 kW

COP Tj = 12°C

7.43

6.58

Cdh

0.99

0.99

Pdh Tj = Tbiv

9.20 kW

8.90 kW

COP Tj = Tbiv

2.47

1.79

Pdh Tj = TOL

6.50 kW

6.50 kW

COP Tj = TOL

1.33

1.40

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electricity

electricity

Supplementary Heater: PSUP

1.80 kW

1.70 kW

Annual energy consumption Qhe

4993 kWh

6288 kWh

PUHZ-SW100VHA(-BS) & EHST20C-M*C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

11.20 kW

El input

n/a

4.46 kW

COP

n/a

2.51

Indoor water flow rate

n/a

1.20 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level indoor

n/a

40 dB(A)

Sound power level outdoor

n/a

70 dB(A)

EN 14825

Medium temperature

ηs

n/a

125 %

Prated

n/a

10.00 kW

SCOP

n/a

3.20

Tbiv

n/a

-7 °C

TOL

n/a

-20 °C

Pdh Tj = -7°C

n/a

8.90 kW

COP Tj = -7°C

n/a

1.79

Cdh

n/a

0.98

Pdh Tj = +2°C

n/a

5.40 kW

COP Tj = +2°C

n/a

3.18

Cdh

n/a

0.98

Pdh Tj = +7°C

n/a

3.90 kW

COP Tj = +7°C

n/a

4.37

Cdh

n/a

0.98

Pdh Tj = 12°C

n/a

7.00 kW

COP Tj = 12°C

n/a

6.58

Cdh

n/a

0.98

Pdh Tj = Tbiv

n/a

8.90 kW

COP Tj = Tbiv

n/a

1.79

Pdh Tj = TOL

n/a

6.50 kW

COP Tj = TOL

n/a

1.33

WTOL

n/a

60 °C

Poff

n/a

15 W

PTO

n/a

15 W

PSB

n/a

15 W

PCK

n/a

0 W

Supplementary Heater: Type of energy input

n/a

electricity

Supplementary Heater: PSUP

n/a

1.70 kW

Annual energy consumption Qhe

n/a

6331 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

103 %

COP

2.48

Heating up time

1:46 h:min

Standby power input

36.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

292 l

PUHZ-SW100VHA(-BS) & EHST20C-VM*C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

11.20 kW

El input

n/a

4.46 kW

COP

n/a

2.51

Indoor water flow rate

n/a

1.20 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level indoor

n/a

40 dB(A)

Sound power level outdoor

n/a

70 dB(A)

EN 14825

Medium temperature

ηs

n/a

125 %

Prated

n/a

10.00 kW

SCOP

n/a

3.20

Tbiv

n/a

-7 °C

TOL

n/a

-20 °C

Pdh Tj = -7°C

n/a

8.90 kW

COP Tj = -7°C

n/a

1.79

Cdh

n/a

0.98

Pdh Tj = +2°C

n/a

5.40 kW

COP Tj = +2°C

n/a

3.18

Cdh

n/a

0.98

Pdh Tj = +7°C

n/a

3.90 kW

COP Tj = +7°C

n/a

4.37

Cdh

n/a

0.98

Pdh Tj = 12°C

n/a

7.00 kW

COP Tj = 12°C

n/a

6.58

Cdh

n/a

0.98

Pdh Tj = Tbiv

n/a

8.90 kW

COP Tj = Tbiv

n/a

1.79

Pdh Tj = TOL

n/a

6.50 kW

COP Tj = TOL

n/a

1.33

WTOL

n/a

60 °C

Poff

n/a

15 W

PTO

n/a

15 W

PSB

n/a

15 W

PCK

n/a

0 W

Supplementary Heater: Type of energy input

n/a

electricity

Supplementary Heater: PSUP

n/a

1.70 kW

Annual energy consumption Qhe

n/a

6331 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

103 %

COP

2.48

Heating up time

1:46 h:min

Standby power input

36.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

292 l

PUHZ-SW100VHA(-BS) & EHST20C-YM*C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

11.20 kW

El input

n/a

4.46 kW

COP

n/a

2.51

Indoor water flow rate

n/a

1.20 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level indoor

n/a

40 dB(A)

Sound power level outdoor

n/a

70 dB(A)

EN 14825

Medium temperature

ηs

n/a

125 %

Prated

n/a

10.00 kW

SCOP

n/a

3.20

Tbiv

n/a

-7 °C

TOL

n/a

-20 °C

Pdh Tj = -7°C

n/a

8.90 kW

COP Tj = -7°C

n/a

1.79

Cdh

n/a

0.98

Pdh Tj = +2°C

n/a

5.40 kW

COP Tj = +2°C

n/a

3.18

Cdh

n/a

0.98

Pdh Tj = +7°C

n/a

3.90 kW

COP Tj = +7°C

n/a

4.37

Cdh

n/a

0.98

Pdh Tj = 12°C

n/a

7.00 kW

COP Tj = 12°C

n/a

6.58

Cdh

n/a

0.98

Pdh Tj = Tbiv

n/a

8.90 kW

COP Tj = Tbiv

n/a

1.79

Pdh Tj = TOL

n/a

6.50 kW

COP Tj = TOL

n/a

1.33

WTOL

n/a

60 °C

Poff

n/a

15 W

PTO

n/a

15 W

PSB

n/a

15 W

PCK

n/a

0 W

Supplementary Heater: Type of energy input

n/a

electricity

Supplementary Heater: PSUP

n/a

1.70 kW

Annual energy consumption Qhe

n/a

6331 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

103 %

COP

2.48

Heating up time

1:46 h:min

Standby power input

36.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

292 l

PUHZ-SW100YHA(-BS) & EHST20C-M*C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

11.20 kW

El input

n/a

4.46 kW

COP

n/a

2.51

Indoor water flow rate

n/a

1.20 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level indoor

n/a

40 dB(A)

Sound power level outdoor

n/a

70 dB(A)

EN 14825

Medium temperature

ηs

n/a

125 %

Prated

n/a

10.00 kW

SCOP

n/a

3.20

Tbiv

n/a

-7 °C

TOL

n/a

-20 °C

Pdh Tj = -7°C

n/a

8.90 kW

COP Tj = -7°C

n/a

1.79

Cdh

n/a

0.99

Pdh Tj = +2°C

n/a

5.40 kW

COP Tj = +2°C

n/a

3.21

Cdh

n/a

0.99

Pdh Tj = +7°C

n/a

3.90 kW

COP Tj = +7°C

n/a

4.39

Cdh

n/a

0.99

Pdh Tj = 12°C

n/a

7.00 kW

COP Tj = 12°C

n/a

6.58

Cdh

n/a

0.99

Pdh Tj = Tbiv

n/a

8.90 kW

COP Tj = Tbiv

n/a

1.79

Pdh Tj = TOL

n/a

6.50 kW

COP Tj = TOL

n/a

1.40

WTOL

n/a

60 °C

Poff

n/a

22 W

PTO

n/a

22 W

PSB

n/a

22 W

PCK

n/a

0 W

Supplementary Heater: Type of energy input

n/a

electricity

Supplementary Heater: PSUP

n/a

1.70 kW

Annual energy consumption Qhe

n/a

6288 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

103 %

COP

2.48

Heating up time

1:46 h:min

Standby power input

36.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

292 l

PUHZ-SW100YHA(-BS) & EHST20C-VM*C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

11.20 kW

El input

n/a

4.46 kW

COP

n/a

2.51

Indoor water flow rate

n/a

1.20 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level indoor

n/a

40 dB(A)

Sound power level outdoor

n/a

70 dB(A)

EN 14825

Medium temperature

ηs

n/a

125 %

Prated

n/a

10.00 kW

SCOP

n/a

3.20

Tbiv

n/a

-7 °C

TOL

n/a

-20 °C

Pdh Tj = -7°C

n/a

8.90 kW

COP Tj = -7°C

n/a

1.79

Cdh

n/a

0.99

Pdh Tj = +2°C

n/a

5.40 kW

COP Tj = +2°C

n/a

3.21

Cdh

n/a

0.99

Pdh Tj = +7°C

n/a

3.90 kW

COP Tj = +7°C

n/a

4.39

Cdh

n/a

0.99

Pdh Tj = 12°C

n/a

7.00 kW

COP Tj = 12°C

n/a

6.58

Cdh

n/a

0.99

Pdh Tj = Tbiv

n/a

8.90 kW

COP Tj = Tbiv

n/a

1.79

Pdh Tj = TOL

n/a

6.50 kW

COP Tj = TOL

n/a

1.40

WTOL

n/a

60 °C

Poff

n/a

22 W

PTO

n/a

22 W

PSB

n/a

22 W

PCK

n/a

0 W

Supplementary Heater: Type of energy input

n/a

electricity

Supplementary Heater: PSUP

n/a

1.70 kW

Annual energy consumption Qhe

n/a

6288 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

103 %

COP

2.48

Heating up time

1:46 h:min

Standby power input

36.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

292 l

PUHZ-SW100YHA(-BS) & EHST20C-YM*C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

11.20 kW

El input

n/a

4.46 kW

COP

n/a

2.51

Indoor water flow rate

n/a

1.20 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level indoor

n/a

40 dB(A)

Sound power level outdoor

n/a

70 dB(A)

EN 14825

Medium temperature

ηs

n/a

125 %

Prated

n/a

10.00 kW

SCOP

n/a

3.20

Tbiv

n/a

-7 °C

TOL

n/a

-20 °C

Pdh Tj = -7°C

n/a

8.90 kW

COP Tj = -7°C

n/a

1.79

Cdh

n/a

0.99

Pdh Tj = +2°C

n/a

5.40 kW

COP Tj = +2°C

n/a

3.21

Cdh

n/a

0.99

Pdh Tj = +7°C

n/a

3.90 kW

COP Tj = +7°C

n/a

4.39

Cdh

n/a

0.99

Pdh Tj = 12°C

n/a

7.00 kW

COP Tj = 12°C

n/a

6.58

Cdh

n/a

0.99

Pdh Tj = Tbiv

n/a

8.90 kW

COP Tj = Tbiv

n/a

1.79

Pdh Tj = TOL

n/a

6.50 kW

COP Tj = TOL

n/a

1.40

WTOL

n/a

60 °C

Poff

n/a

22 W

PTO

n/a

22 W

PSB

n/a

22 W

PCK

n/a

0 W

Supplementary Heater: Type of energy input

n/a

electricity

Supplementary Heater: PSUP

n/a

1.70 kW

Annual energy consumption Qhe

n/a

6288 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

103 %

COP

2.48

Heating up time

1:46 h:min

Standby power input

36.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

292 l

PUHZ-SW100VHA(-BS) & ERSC-M*C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

11.20 kW

El input

2.52 kW

4.46 kW

COP

4.44

2.51

Indoor water flow rate

1.93 m³/h

1.20 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

166 %

127 %

Prated

10.40 kW

10.00 kW

SCOP

4.23

3.24

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

9.20 kW

8.90 kW

COP Tj = -7°C

2.47

1.79

Cdh

0.98

0.98

Pdh Tj = +2°C

5.60 kW

5.40 kW

COP Tj = +2°C

4.24

3.18

Cdh

0.98

0.98

Pdh Tj = +7°C

4.30 kW

3.90 kW

COP Tj = +7°C

5.49

4.37

Cdh

0.98

0.98

Pdh Tj = 12°C

7.30 kW

7.00 kW

COP Tj = 12°C

7.43

6.58

Cdh

0.98

0.98

Pdh Tj = Tbiv

9.20 kW

8.90 kW

COP Tj = Tbiv

2.47

1.79

Pdh Tj = TOL

6.50 kW

6.50 kW

COP Tj = TOL

1.40

1.33

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electricity

electricity

Supplementary Heater: PSUP

1.80 kW

1.70 kW

Annual energy consumption Qhe

5027 kWh

6331 kWh

PUHZ-SW100VHA(-BS) & ERSC-VM*C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

11.20 kW

El input

2.52 kW

4.46 kW

COP

4.44

2.51

Indoor water flow rate

1.93 m³/h

1.20 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

166 %

127 %

Prated

10.40 kW

10.00 kW

SCOP

4.23

3.24

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

9.20 kW

8.90 kW

COP Tj = -7°C

2.47

1.79

Cdh

0.98

0.98

Pdh Tj = +2°C

5.60 kW

5.40 kW

COP Tj = +2°C

4.24

3.18

Cdh

0.98

0.98

Pdh Tj = +7°C

4.30 kW

3.90 kW

COP Tj = +7°C

5.49

4.37

Cdh

0.98

0.98

Pdh Tj = 12°C

7.30 kW

7.00 kW

COP Tj = 12°C

7.43

6.58

Cdh

0.98

0.98

Pdh Tj = Tbiv

9.20 kW

8.90 kW

COP Tj = Tbiv

2.47

1.79

Pdh Tj = TOL

6.50 kW

6.50 kW

COP Tj = TOL

1.40

1.33

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electricity

electricity

Supplementary Heater: PSUP

1.80 kW

1.70 kW

Annual energy consumption Qhe

5027 kWh

6331 kWh

PUHZ-SW100YHA(-BS) & ERSC-M*C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

11.20 kW

El input

2.52 kW

4.46 kW

COP

4.44

2.51

Indoor water flow rate

1.93 m³/h

1.20 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

166 %

127 %

Prated

10.40 kW

10.00 kW

SCOP

4.23

3.24

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

9.20 kW

8.90 kW

COP Tj = -7°C

2.47

1.79

Cdh

0.99

0.99

Pdh Tj = +2°C

5.60 kW

5.40 kW

COP Tj = +2°C

4.27

3.21

Cdh

0.99

0.99

Pdh Tj = +7°C

4.30 kW

3.90 kW

COP Tj = +7°C

5.54

4.39

Cdh

0.99

0.99

Pdh Tj = 12°C

7.30 kW

7.00 kW

COP Tj = 12°C

7.43

6.58

Cdh

0.99

0.99

Pdh Tj = Tbiv

9.20 kW

8.90 kW

COP Tj = Tbiv

2.47

1.79

Pdh Tj = TOL

6.50 kW

6.50 kW

COP Tj = TOL

1.33

1.40

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electricity

electricity

Supplementary Heater: PSUP

1.80 kW

1.70 kW

Annual energy consumption Qhe

4993 kWh

6288 kWh

PUHZ-SW100YHA(-BS) & ERSC-VM*C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

11.20 kW

El input

2.52 kW

4.46 kW

COP

4.44

2.51

Indoor water flow rate

1.93 m³/h

1.20 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

70 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

166 %

127 %

Prated

10.40 kW

10.00 kW

SCOP

4.23

3.24

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

9.20 kW

8.90 kW

COP Tj = -7°C

2.47

1.79

Cdh

0.99

0.99

Pdh Tj = +2°C

5.60 kW

5.40 kW

COP Tj = +2°C

4.27

3.21

Cdh

0.99

0.99

Pdh Tj = +7°C

4.30 kW

3.90 kW

COP Tj = +7°C

5.54

4.39

Cdh

0.99

0.99

Pdh Tj = 12°C

7.30 kW

7.00 kW

COP Tj = 12°C

7.43

6.58

Cdh

0.99

0.99

Pdh Tj = Tbiv

9.20 kW

8.90 kW

COP Tj = Tbiv

2.47

1.79

Pdh Tj = TOL

6.50 kW

6.50 kW

COP Tj = TOL

1.33

1.40

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electricity

electricity

Supplementary Heater: PSUP

1.80 kW

1.70 kW

Annual energy consumption Qhe

4993 kWh

6288 kWh

PUHZ-SW100VHA(-BS) & ERST20C-M*C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

11.20 kW

El input

n/a

4.46 kW

COP

n/a

2.51

Indoor water flow rate

n/a

1.20 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level indoor

n/a

40 dB(A)

Sound power level outdoor

n/a

70 dB(A)

EN 14825

Medium temperature

ηs

n/a

127 %

Prated

n/a

10.00 kW

SCOP

n/a

3.24

Tbiv

n/a

-7 °C

TOL

n/a

-20 °C

Pdh Tj = -7°C

n/a

8.90 kW

COP Tj = -7°C

n/a

1.79

Cdh

n/a

0.98

Pdh Tj = +2°C

n/a

5.40 kW

COP Tj = +2°C

n/a

3.18

Cdh

n/a

0.98

Pdh Tj = +7°C

n/a

3.90 kW

COP Tj = +7°C

n/a

4.37

Cdh

n/a

0.98

Pdh Tj = 12°C

n/a

7.00 kW

COP Tj = 12°C

n/a

6.58

Cdh

n/a

0.98

Pdh Tj = Tbiv

n/a

8.90 kW

COP Tj = Tbiv

n/a

1.79

Pdh Tj = TOL

n/a

6.50 kW

COP Tj = TOL

n/a

1.33

WTOL

n/a

60 °C

Poff

n/a

15 W

PTO

n/a

15 W

PSB

n/a

15 W

PCK

n/a

0 W

Supplementary Heater: Type of energy input

n/a

electricity

Supplementary Heater: PSUP

n/a

1.70 kW

Annual energy consumption Qhe

n/a

6331 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

103 %

COP

2.48

Heating up time

1:46 h:min

Standby power input

36.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

292 l

PUHZ-SW100VHA(-BS) & ERST20C-VM*C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

11.20 kW

El input

n/a

4.46 kW

COP

n/a

2.51

Indoor water flow rate

n/a

1.20 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level indoor

n/a

40 dB(A)

Sound power level outdoor

n/a

70 dB(A)

EN 14825

Medium temperature

ηs

n/a

127 %

Prated

n/a

10.00 kW

SCOP

n/a

3.24

Tbiv

n/a

-7 °C

TOL

n/a

-20 °C

Pdh Tj = -7°C

n/a

8.90 kW

COP Tj = -7°C

n/a

1.79

Cdh

n/a

0.98

Pdh Tj = +2°C

n/a

5.40 kW

COP Tj = +2°C

n/a

3.18

Cdh

n/a

0.98

Pdh Tj = +7°C

n/a

3.90 kW

COP Tj = +7°C

n/a

4.37

Cdh

n/a

0.98

Pdh Tj = 12°C

n/a

7.00 kW

COP Tj = 12°C

n/a

6.58

Cdh

n/a

0.98

Pdh Tj = Tbiv

n/a

8.90 kW

COP Tj = Tbiv

n/a

1.79

Pdh Tj = TOL

n/a

6.50 kW

COP Tj = TOL

n/a

1.33

WTOL

n/a

60 °C

Poff

n/a

15 W

PTO

n/a

15 W

PSB

n/a

15 W

PCK

n/a

0 W

Supplementary Heater: Type of energy input

n/a

electricity

Supplementary Heater: PSUP

n/a

1.70 kW

Annual energy consumption Qhe

n/a

6331 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

103 %

COP

2.48

Heating up time

1:46 h:min

Standby power input

36.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

292 l

PUHZ-SW100YHA(-BS) & ERST20C-M*C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

11.20 kW

El input

n/a

4.46 kW

COP

n/a

2.51

Indoor water flow rate

n/a

1.20 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level indoor

n/a

40 dB(A)

Sound power level outdoor

n/a

70 dB(A)

EN 14825

Medium temperature

ηs

n/a

127 %

Prated

n/a

10.00 kW

SCOP

n/a

3.24

Tbiv

n/a

-7 °C

TOL

n/a

-20 °C

Pdh Tj = -7°C

n/a

8.90 kW

COP Tj = -7°C

n/a

1.79

Cdh

n/a

0.99

Pdh Tj = +2°C

n/a

5.40 kW

COP Tj = +2°C

n/a

3.21

Cdh

n/a

0.99

Pdh Tj = +7°C

n/a

3.90 kW

COP Tj = +7°C

n/a

4.39

Cdh

n/a

0.99

Pdh Tj = 12°C

n/a

7.00 kW

COP Tj = 12°C

n/a

6.58

Cdh

n/a

0.99

Pdh Tj = Tbiv

n/a

8.90 kW

COP Tj = Tbiv

n/a

1.79

Pdh Tj = TOL

n/a

6.50 kW

COP Tj = TOL

n/a

1.40

WTOL

n/a

60 °C

Poff

n/a

22 W

PTO

n/a

22 W

PSB

n/a

22 W

PCK

n/a

0 W

Supplementary Heater: Type of energy input

n/a

electricity

Supplementary Heater: PSUP

n/a

1.70 kW

Annual energy consumption Qhe

n/a

6288 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

103 %

COP

2.48

Heating up time

1:46 h:min

Standby power input

36.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

292 l

PUHZ-SW100YHA(-BS) & ERST20C-VM*C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.20 kW

11.20 kW

El input

n/a

4.46 kW

COP

n/a

2.51

Indoor water flow rate

n/a

1.20 m³/h

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Medium temperature

Sound power level indoor

n/a

40 dB(A)

Sound power level outdoor

n/a

70 dB(A)

EN 14825

Medium temperature

ηs

n/a

127 %

Prated

n/a

10.00 kW

SCOP

n/a

3.24

Tbiv

n/a

-7 °C

TOL

n/a

-20 °C

Pdh Tj = -7°C

n/a

8.90 kW

COP Tj = -7°C

n/a

1.79

Cdh

n/a

0.99

Pdh Tj = +2°C

n/a

5.40 kW

COP Tj = +2°C

n/a

3.21

Cdh

n/a

0.99

Pdh Tj = +7°C

n/a

3.90 kW

COP Tj = +7°C

n/a

4.39

Cdh

n/a

0.99

Pdh Tj = 12°C

n/a

7.00 kW

COP Tj = 12°C

n/a

6.58

Cdh

n/a

0.99

Pdh Tj = Tbiv

n/a

8.90 kW

COP Tj = Tbiv

n/a

1.79

Pdh Tj = TOL

n/a

6.50 kW

COP Tj = TOL

n/a

1.40

WTOL

n/a

60 °C

Poff

n/a

22 W

PTO

n/a

22 W

PSB

n/a

22 W

PCK

n/a

0 W

Supplementary Heater: Type of energy input

n/a

electricity

Supplementary Heater: PSUP

n/a

1.70 kW

Annual energy consumption Qhe

n/a

6288 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

103 %

COP

2.48

Heating up time

1:46 h:min

Standby power input

36.0 W

Reference hot water temperature

52.5 °C

Mixed water at 40°C

292 l