Certificate holders

Subtype

Bosch Compress 3000 AWS-11/13/15

Certificate Holder
Bosch Thermotechnik GmbH
Sophienstraße 30-32
35576 Wetzlar
Germany
Reg. No.
011-1W0136
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Name of testing laboratory
RISE Research Institutes of Sweden
Subtype title
Bosch Compress 3000 AWS-11/13/15
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
HFC-410a
Mass Of Refrigerant

2,300 kg

Certification Date
26.09.2017
Testing basis
n/a
Generate PDF Export model CSV

Models

Bosch Compress 3000 AWS-13 MS
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.21 kW

8.02 kW

El input

2.09 kW

2.96 kW

COP

4.40

2.70

Indoor water flow rate

1.57 m³/h

0.88 m³/h

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

Sound power level outdoor

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

153 %

121 %

Prated

11.00 kW

10.00 kW

SCOP

3.90

3.10

Tbiv

-10 °C

-10 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

9.90 kW

8.40 kW

COP Tj = -7°C

2.71

2.11

Pdh Tj = +2°C

6.00 kW

6.00 kW

COP Tj = +2°C

3.72

3.11

Pdh Tj = +7°C

6.50 kW

6.00 kW

COP Tj = +7°C

5.71

4.31

Pdh Tj = 12°C

6.50 kW

6.00 kW

COP Tj = 12°C

5.71

5.01

Pdh Tj = Tbiv

11.20 kW

9.50 kW

COP Tj = Tbiv

2.61

1.81

Pdh Tj = TOL

11.20 kW

9.50 kW

COP Tj = TOL

2.61

1.81

Cdh

0.90

0.90

WTOL

57 °C

57 °C

Poff

11 W

11 W

PTO

51 W

51 W

PSB

11 W

11 W

PCK

100 W

100 W

Supplementary Heater: Type of energy input

Electric

Electric

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5949 kWh

6356 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

71 %

COP

1.68

Standby power input

60.0 W

Reference hot water temperature

56.4 °C

Mixed water at 40°C

304 l

Heating up time

3:20 h:min

Bosch Compress 3000 AWS-13 M
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.21 kW

8.02 kW

El input

2.09 kW

2.96 kW

COP

4.40

2.70

Indoor water flow rate

1.57 m³/h

0.88 m³/h

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

Sound power level outdoor

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

153 %

121 %

Prated

11.00 kW

10.00 kW

SCOP

3.90

3.10

Tbiv

-10 °C

-10 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

9.90 kW

8.40 kW

COP Tj = -7°C

2.71

2.11

Pdh Tj = +2°C

6.00 kW

6.00 kW

COP Tj = +2°C

3.72

3.11

Pdh Tj = +7°C

6.50 kW

6.00 kW

COP Tj = +7°C

5.71

4.31

Pdh Tj = 12°C

6.50 kW

6.00 kW

COP Tj = 12°C

5.71

5.01

Pdh Tj = Tbiv

11.20 kW

9.50 kW

COP Tj = Tbiv

2.61

1.81

Pdh Tj = TOL

11.20 kW

9.50 kW

COP Tj = TOL

2.61

1.81

Cdh

0.90

0.90

WTOL

57 °C

57 °C

Poff

11 W

11 W

PTO

51 W

51 W

PSB

11 W

11 W

PCK

100 W

100 W

Supplementary Heater: Type of energy input

Electric

Electric

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5949 kWh

6356 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

71 %

COP

1.68

Heating up time

3:20 h:min

Standby power input

60.0 W

Reference hot water temperature

56.4 °C

Mixed water at 40°C

304 l

Bosch Compress 3000 AWS-13 B
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.21 kW

8.02 kW

El input

2.09 kW

2.96 kW

COP

4.40

2.70

Indoor water flow rate

1.57 m³/h

0.88 m³/h

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

Sound power level outdoor

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

153 %

121 %

Prated

11.00 kW

10.00 kW

SCOP

3.90

3.10

Tbiv

-10 °C

-10 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

9.90 kW

8.40 kW

COP Tj = -7°C

2.71

2.11

Pdh Tj = +2°C

6.00 kW

6.00 kW

COP Tj = +2°C

3.72

3.11

Pdh Tj = +7°C

6.50 kW

6.00 kW

COP Tj = +7°C

5.71

4.31

Pdh Tj = 12°C

6.50 kW

6.00 kW

COP Tj = 12°C

5.71

5.01

Pdh Tj = Tbiv

11.20 kW

9.50 kW

COP Tj = Tbiv

2.61

1.81

Pdh Tj = TOL

11.20 kW

9.50 kW

COP Tj = TOL

2.61

1.81

Cdh

0.90

0.90

WTOL

57 °C

57 °C

Poff

11 W

11 W

PTO

51 W

51 W

PSB

11 W

11 W

PCK

100 W

100 W

Supplementary Heater: Type of energy input

Electric

Electric

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5949 kWh

6356 kWh

Bosch Compress 3000 AWS-13 E
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.21 kW

8.02 kW

El input

2.09 kW

2.96 kW

COP

4.40

2.70

Indoor water flow rate

1.57 m³/h

0.88 m³/h

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

Sound power level outdoor

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

153 %

121 %

Prated

11.00 kW

10.00 kW

SCOP

3.90

3.10

Tbiv

-10 °C

-10 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

9.90 kW

8.40 kW

COP Tj = -7°C

2.71

2.11

Pdh Tj = +2°C

6.00 kW

6.00 kW

COP Tj = +2°C

3.72

3.11

Pdh Tj = +7°C

6.50 kW

6.00 kW

COP Tj = +7°C

5.71

4.31

Pdh Tj = 12°C

6.50 kW

6.00 kW

COP Tj = 12°C

5.71

5.01

Pdh Tj = Tbiv

11.20 kW

9.50 kW

COP Tj = Tbiv

2.61

1.81

Pdh Tj = TOL

11.20 kW

9.50 kW

COP Tj = TOL

2.61

1.81

Cdh

0.90

0.90

WTOL

57 °C

57 °C

Poff

11 W

11 W

PTO

51 W

51 W

PSB

11 W

11 W

PCK

100 W

100 W

Supplementary Heater: Type of energy input

Electric

Electric

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5949 kWh

6356 kWh

Bosch Compress 3000 AWS-11 MS
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.60 kW

7.50 kW

El input

1.95 kW

2.78 kW

COP

4.40

2.70

Indoor water flow rate

1.47 m³/h

0.83 m³/h

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

Sound power level outdoor

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

119 %

Prated

10.00 kW

9.00 kW

SCOP

3.88

3.05

Tbiv

-10 °C

-10 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

8.80 kW

7.50 kW

COP Tj = -7°C

2.71

2.10

Pdh Tj = +2°C

5.90 kW

6.00 kW

COP Tj = +2°C

3.81

3.11

Pdh Tj = +7°C

6.50 kW

6.00 kW

COP Tj = +7°C

5.71

4.30

Pdh Tj = 12°C

6.50 kW

6.00 kW

COP Tj = 12°C

5.71

5.01

Pdh Tj = Tbiv

10.00 kW

8.50 kW

COP Tj = Tbiv

2.61

1.81

Pdh Tj = TOL

10.00 kW

8.50 kW

COP Tj = TOL

2.61

1.81

Cdh

0.90

0.90

WTOL

57 °C

57 °C

Poff

11 W

11 W

PTO

51 W

51 W

PSB

11 W

11 W

PCK

100 W

100 W

Supplementary Heater: Type of energy input

Electric

Electric

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5324 kWh

5770 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

71 %

COP

1.68

Heating up time

3:20 h:min

Standby power input

60.0 W

Reference hot water temperature

56.4 °C

Mixed water at 40°C

304 l

Bosch Compress 3000 AWS-11 M
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.60 kW

7.50 kW

El input

1.95 kW

2.78 kW

COP

4.40

2.70

Indoor water flow rate

1.47 m³/h

0.83 m³/h

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

Sound power level outdoor

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

119 %

Prated

10.00 kW

9.00 kW

SCOP

3.88

3.05

Tbiv

-10 °C

-10 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

8.80 kW

7.50 kW

COP Tj = -7°C

2.71

2.10

Pdh Tj = +2°C

5.90 kW

6.00 kW

COP Tj = +2°C

3.81

3.11

Pdh Tj = +7°C

6.50 kW

6.00 kW

COP Tj = +7°C

5.71

4.30

Pdh Tj = 12°C

6.50 kW

6.00 kW

COP Tj = 12°C

5.71

5.01

Pdh Tj = Tbiv

10.00 kW

8.50 kW

COP Tj = Tbiv

2.61

1.81

Pdh Tj = TOL

10.00 kW

8.50 kW

COP Tj = TOL

2.61

1.81

Cdh

0.90

0.90

WTOL

57 °C

57 °C

Poff

11 W

11 W

PTO

51 W

51 W

PSB

11 W

11 W

PCK

100 W

100 W

Supplementary Heater: Type of energy input

Electric

Electric

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5324 kWh

5770 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

71 %

COP

1.68

Heating up time

3:20 h:min

Standby power input

60.0 W

Reference hot water temperature

56.4 °C

Mixed water at 40°C

304 l

Bosch Compress 3000 AWS-11 B
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.60 kW

7.50 kW

El input

1.95 kW

2.78 kW

COP

4.40

2.70

Indoor water flow rate

1.47 m³/h

0.83 m³/h

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

Sound power level outdoor

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

119 %

Prated

10.00 kW

9.00 kW

SCOP

3.88

3.05

Tbiv

-10 °C

-10 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

8.80 kW

7.50 kW

COP Tj = -7°C

2.71

2.10

Pdh Tj = +2°C

5.90 kW

6.00 kW

COP Tj = +2°C

3.81

3.11

Pdh Tj = +7°C

6.50 kW

6.00 kW

COP Tj = +7°C

5.71

4.30

Pdh Tj = 12°C

6.50 kW

6.00 kW

COP Tj = 12°C

5.71

5.01

Pdh Tj = Tbiv

10.00 kW

8.50 kW

COP Tj = Tbiv

2.61

1.81

Pdh Tj = TOL

10.00 kW

8.50 kW

COP Tj = TOL

2.61

1.81

Cdh

0.90

0.90

WTOL

57 °C

57 °C

Poff

11 W

11 W

PTO

51 W

51 W

PSB

11 W

11 W

PCK

100 W

100 W

Supplementary Heater: Type of energy input

Electric

Electric

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5324 kWh

5770 kWh

Bosch Compress 3000 AWS-11 E
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.60 kW

7.50 kW

El input

1.95 kW

2.78 kW

COP

4.40

2.70

Indoor water flow rate

1.47 m³/h

0.83 m³/h

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

Sound power level outdoor

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

119 %

Prated

10.00 kW

9.00 kW

SCOP

3.88

3.05

Tbiv

-10 °C

-10 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

8.80 kW

7.50 kW

COP Tj = -7°C

2.71

2.10

Pdh Tj = +2°C

5.90 kW

6.00 kW

COP Tj = +2°C

3.81

3.11

Pdh Tj = +7°C

6.50 kW

6.00 kW

COP Tj = +7°C

5.71

4.30

Pdh Tj = 12°C

6.50 kW

6.00 kW

COP Tj = 12°C

5.71

5.01

Pdh Tj = Tbiv

10.00 kW

8.50 kW

COP Tj = Tbiv

2.61

1.81

Pdh Tj = TOL

10.00 kW

8.50 kW

COP Tj = TOL

2.61

1.81

Cdh

0.90

0.90

WTOL

57 °C

57 °C

Poff

11 W

11 W

PTO

51 W

51 W

PSB

11 W

11 W

PCK

100 W

100 W

Supplementary Heater: Type of energy input

Electric

Electric

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5324 kWh

5770 kWh

Bosch Compress 3000 AWS-15 MS
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.65 kW

8.36 kW

El input

2.19 kW

3.06 kW

COP

4.41

2.73

Indoor water flow rate

1.64 m³/h

0.92 m³/h

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

Sound power level outdoor

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

153 %

123 %

Prated

13.00 kW

11.00 kW

SCOP

3.90

3.15

Tbiv

-10 °C

-10 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

11.10 kW

9.30 kW

COP Tj = -7°C

2.71

2.11

Pdh Tj = +2°C

6.70 kW

6.00 kW

COP Tj = +2°C

3.71

3.11

Pdh Tj = +7°C

6.50 kW

6.00 kW

COP Tj = +7°C

5.71

4.31

Pdh Tj = 12°C

6.50 kW

6.00 kW

COP Tj = 12°C

5.71

5.01

Pdh Tj = Tbiv

12.50 kW

10.50 kW

COP Tj = Tbiv

2.61

1.81

Pdh Tj = TOL

12.50 kW

10.50 kW

COP Tj = TOL

2.61

1.81

Cdh

0.90

0.90

WTOL

57 °C

57 °C

Poff

11 W

11 W

PTO

51 W

51 W

PSB

11 W

11 W

PCK

100 W

100 W

Supplementary Heater: Type of energy input

Electric

Electric

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6612 kWh

6942 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

71 %

COP

1.68

Heating up time

3:20 h:min

Standby power input

60.0 W

Reference hot water temperature

56.4 °C

Mixed water at 40°C

304 l

Bosch Compress 3000 AWS-15 M
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.65 kW

8.36 kW

El input

2.19 kW

3.06 kW

COP

4.41

2.73

Indoor water flow rate

1.64 m³/h

0.92 m³/h

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

Sound power level outdoor

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

153 %

123 %

Prated

13.00 kW

11.00 kW

SCOP

3.90

3.15

Tbiv

-10 °C

-10 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

11.10 kW

9.30 kW

COP Tj = -7°C

2.71

2.11

Pdh Tj = +2°C

6.70 kW

6.00 kW

COP Tj = +2°C

3.71

3.11

Pdh Tj = +7°C

6.50 kW

6.00 kW

COP Tj = +7°C

5.71

4.31

Pdh Tj = 12°C

6.50 kW

6.00 kW

COP Tj = 12°C

5.71

5.01

Pdh Tj = Tbiv

12.50 kW

10.50 kW

COP Tj = Tbiv

2.61

1.81

Pdh Tj = TOL

12.50 kW

10.50 kW

COP Tj = TOL

2.61

1.81

Cdh

0.90

0.90

WTOL

57 °C

57 °C

Poff

11 W

11 W

PTO

51 W

51 W

PSB

11 W

11 W

PCK

100 W

100 W

Supplementary Heater: Type of energy input

Electric

Electric

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6612 kWh

6942 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

71 %

COP

1.68

Heating up time

3:20 h:min

Standby power input

60.0 W

Reference hot water temperature

56.4 °C

Mixed water at 40°C

304 l

Bosch Compress 3000 AWS-15 B
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.65 kW

8.36 kW

El input

2.19 kW

3.06 kW

COP

4.41

2.73

Indoor water flow rate

1.64 m³/h

0.92 m³/h

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

Sound power level outdoor

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

153 %

123 %

Prated

13.00 kW

11.00 kW

SCOP

3.90

3.15

Tbiv

-10 °C

-10 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

11.10 kW

9.30 kW

COP Tj = -7°C

2.71

2.11

Pdh Tj = +2°C

6.70 kW

6.00 kW

COP Tj = +2°C

3.71

3.11

Pdh Tj = +7°C

6.50 kW

6.00 kW

COP Tj = +7°C

5.71

4.31

Pdh Tj = 12°C

6.50 kW

6.00 kW

COP Tj = 12°C

5.71

5.01

Pdh Tj = Tbiv

12.50 kW

10.50 kW

COP Tj = Tbiv

2.61

1.81

Pdh Tj = TOL

12.50 kW

10.50 kW

COP Tj = TOL

2.61

1.81

Cdh

0.90

0.90

WTOL

57 °C

57 °C

Poff

11 W

11 W

PTO

51 W

51 W

PSB

11 W

11 W

PCK

100 W

100 W

Supplementary Heater: Type of energy input

Electric

Electric

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6612 kWh

6942 kWh

Bosch Compress 3000 AWS-15 E
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.65 kW

8.36 kW

El input

2.19 kW

3.06 kW

COP

4.41

2.73

Indoor water flow rate

1.64 m³/h

0.92 m³/h

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

Sound power level outdoor

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

153 %

123 %

Prated

13.00 kW

11.00 kW

SCOP

3.90

3.15

Tbiv

-10 °C

-10 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

11.10 kW

9.30 kW

COP Tj = -7°C

2.71

2.11

Pdh Tj = +2°C

6.70 kW

6.00 kW

COP Tj = +2°C

3.71

3.11

Pdh Tj = +7°C

6.50 kW

6.00 kW

COP Tj = +7°C

5.71

4.31

Pdh Tj = 12°C

6.50 kW

6.00 kW

COP Tj = 12°C

5.71

5.01

Pdh Tj = Tbiv

12.50 kW

10.50 kW

COP Tj = Tbiv

2.61

1.81

Pdh Tj = TOL

12.50 kW

10.50 kW

COP Tj = TOL

2.61

1.81

Cdh

0.90

0.90

WTOL

57 °C

57 °C

Poff

11 W

11 W

PTO

51 W

51 W

PSB

11 W

11 W

PCK

100 W

100 W

Supplementary Heater: Type of energy input

Electric

Electric

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6612 kWh

6942 kWh