1,160 kg
Brine/Water Heat Pump
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
3.15 kW
2.78 kW
El input
0.67 kW
0.93 kW
COP
4.72
2.99
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
211 %
157 %
Prated
5.50 kW
5.50 kW
SCOP
5.48
4.13
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.40 kW
3.40 kW
COP Tj = -7°C
5.17
3.77
Cdh Tj = -7 °C
Pdh Tj = +2°C
2.10 kW
2.10 kW
COP Tj = +2°C
5.91
4.51
Cdh Tj = +2 °C
Pdh Tj = +7°C
1.40 kW
1.40 kW
COP Tj = +7°C
6.36
5.12
Cdh Tj = +7 °C
Pdh Tj = 12°C
1.30 kW
1.20 kW
COP Tj = 12°C
4.15
4.81
Cdh Tj = +12 °C
Pdh Tj = Tbiv
5.40 kW
5.50 kW
COP Tj = Tbiv
4.15
2.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.40 kW
5.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.15
2.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.970
0.980
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
10 W
7 W
PSB
7 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2481 kWh
3287 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
150 %
Prated
5.50 kW
5.50 kW
SCOP
5.20
3.95
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.00 kW
5.00 kW
COP Tj = -7°C
4.37
3.06
Pdh Tj = +2°C
3.10 kW
3.00 kW
COP Tj = +2°C
5.24
3.97
Pdh Tj = +7°C
2.00 kW
2.00 kW
COP Tj = +7°C
5.92
4.63
Pdh Tj = 12°C
1.30 kW
1.20 kW
COP Tj = 12°C
5.95
4.86
Pdh Tj = Tbiv
5.40 kW
5.40 kW
COP Tj = Tbiv
4.15
2.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.40 kW
5.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.15
2.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.99
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
10 W
7 W
PSB
7 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2188 kWh
2875 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
4.30 kW
3.82 kW
El input
0.66 kW
1.00 kW
COP
6.49
3.83
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
282 %
222 %
Prated
7.00 kW
7.00 kW
SCOP
7.25
5.75
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.30 kW
4.30 kW
COP Tj = -7°C
7.00
5.39
Pdh Tj = +2°C
2.70 kW
2.70 kW
COP Tj = +2°C
7.83
6.21
Pdh Tj = +7°C
1.80 kW
1.80 kW
COP Tj = +7°C
8.14
6.85
Pdh Tj = 12°C
1.80 kW
1.60 kW
COP Tj = 12°C
7.70
6.64
Pdh Tj = Tbiv
7.00 kW
7.00 kW
COP Tj = Tbiv
5.79
4.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
7.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.79
4.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.95
0.96
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
18 W
15 W
PSB
10 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2378 kWh
3005 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
270 %
214 %
Prated
7.00 kW
7.00 kW
SCOP
6.95
5.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.30 kW
6.30 kW
COP Tj = -7°C
6.07
4.52
Pdh Tj = +2°C
3.90 kW
3.90 kW
COP Tj = +2°C
7.09
5.62
Pdh Tj = +7°C
2.50 kW
2.50 kW
COP Tj = +7°C
7.84
6.34
Pdh Tj = 12°C
1.80 kW
1.60 kW
COP Tj = 12°C
7.97
6.57
Pdh Tj = Tbiv
7.00 kW
7.00 kW
COP Tj = Tbiv
5.79
4.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
7.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.79
4.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.96
0.97
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
18 W
15 W
PSB
10 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2078 kWh
2611 kWh
Brine/Water Heat Pump
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
3.15 kW
2.78 kW
El input
0.67 kW
0.93 kW
COP
4.72
2.99
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
211 %
157 %
Prated
5.50 kW
5.50 kW
SCOP
5.48
4.13
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.40 kW
3.40 kW
COP Tj = -7°C
5.17
3.77
Cdh Tj = -7 °C
Pdh Tj = +2°C
2.10 kW
2.10 kW
COP Tj = +2°C
5.91
4.51
Cdh Tj = +2 °C
Pdh Tj = +7°C
1.40 kW
1.40 kW
COP Tj = +7°C
6.36
5.12
Cdh Tj = +7 °C
Pdh Tj = 12°C
1.30 kW
1.20 kW
COP Tj = 12°C
4.15
4.81
Cdh Tj = +12 °C
Pdh Tj = Tbiv
5.40 kW
5.50 kW
COP Tj = Tbiv
4.15
2.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.40 kW
5.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.15
2.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.970
0.980
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
10 W
7 W
PSB
7 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2481 kWh
3287 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
150 %
Prated
5.50 kW
5.50 kW
SCOP
5.20
3.95
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.00 kW
5.00 kW
COP Tj = -7°C
4.37
3.06
Pdh Tj = +2°C
3.10 kW
3.00 kW
COP Tj = +2°C
5.24
3.97
Pdh Tj = +7°C
2.00 kW
2.00 kW
COP Tj = +7°C
5.92
4.63
Pdh Tj = 12°C
1.30 kW
1.20 kW
COP Tj = 12°C
5.95
4.86
Pdh Tj = Tbiv
5.40 kW
5.40 kW
COP Tj = Tbiv
4.15
2.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.40 kW
5.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.15
2.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.99
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
10 W
7 W
PSB
7 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2188 kWh
2875 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
4.30 kW
3.82 kW
El input
0.66 kW
1.00 kW
COP
6.49
3.83
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
282 %
222 %
Prated
7.00 kW
7.00 kW
SCOP
7.25
5.75
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.30 kW
4.30 kW
COP Tj = -7°C
7.00
5.39
Pdh Tj = +2°C
2.70 kW
2.70 kW
COP Tj = +2°C
7.83
6.21
Pdh Tj = +7°C
1.80 kW
1.80 kW
COP Tj = +7°C
8.14
6.85
Pdh Tj = 12°C
1.80 kW
1.60 kW
COP Tj = 12°C
7.70
6.64
Pdh Tj = Tbiv
7.00 kW
7.00 kW
COP Tj = Tbiv
5.79
4.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
7.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.79
4.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.95
0.96
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
18 W
15 W
PSB
10 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2378 kWh
3005 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
270 %
214 %
Prated
7.00 kW
7.00 kW
SCOP
6.95
5.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.30 kW
6.30 kW
COP Tj = -7°C
6.07
4.52
Pdh Tj = +2°C
3.90 kW
3.90 kW
COP Tj = +2°C
7.09
5.62
Pdh Tj = +7°C
2.50 kW
2.50 kW
COP Tj = +7°C
7.84
6.34
Pdh Tj = 12°C
1.80 kW
1.60 kW
COP Tj = 12°C
7.97
6.57
Pdh Tj = Tbiv
7.00 kW
7.00 kW
COP Tj = Tbiv
5.79
4.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
7.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.79
4.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.96
0.97
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
18 W
15 W
PSB
10 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2078 kWh
2611 kWh
Brine/Water Heat Pump
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
3.15 kW
2.78 kW
El input
0.67 kW
0.93 kW
COP
4.72
2.99
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
211 %
157 %
Prated
5.50 kW
5.50 kW
SCOP
5.48
4.13
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.40 kW
3.40 kW
COP Tj = -7°C
5.17
3.77
Cdh Tj = -7 °C
Pdh Tj = +2°C
2.10 kW
2.10 kW
COP Tj = +2°C
5.91
4.51
Cdh Tj = +2 °C
Pdh Tj = +7°C
1.40 kW
1.40 kW
COP Tj = +7°C
6.36
5.12
Cdh Tj = +7 °C
Pdh Tj = 12°C
1.30 kW
1.20 kW
COP Tj = 12°C
4.15
4.81
Cdh Tj = +12 °C
Pdh Tj = Tbiv
5.40 kW
5.50 kW
COP Tj = Tbiv
4.15
2.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.40 kW
5.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.15
2.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.970
0.980
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
10 W
7 W
PSB
7 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2481 kWh
3287 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
150 %
Prated
5.50 kW
5.50 kW
SCOP
5.20
3.95
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.00 kW
5.00 kW
COP Tj = -7°C
4.37
3.06
Pdh Tj = +2°C
3.10 kW
3.00 kW
COP Tj = +2°C
5.24
3.97
Pdh Tj = +7°C
2.00 kW
2.00 kW
COP Tj = +7°C
5.92
4.63
Pdh Tj = 12°C
1.30 kW
1.20 kW
COP Tj = 12°C
5.95
4.86
Pdh Tj = Tbiv
5.40 kW
5.40 kW
COP Tj = Tbiv
4.15
2.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.40 kW
5.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.15
2.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.99
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
10 W
7 W
PSB
7 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2188 kWh
2875 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
4.30 kW
3.82 kW
El input
0.66 kW
1.00 kW
COP
6.49
3.83
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
282 %
222 %
Prated
7.00 kW
7.00 kW
SCOP
7.25
5.75
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.30 kW
4.30 kW
COP Tj = -7°C
7.00
5.39
Pdh Tj = +2°C
2.70 kW
2.70 kW
COP Tj = +2°C
7.83
6.21
Pdh Tj = +7°C
1.80 kW
1.80 kW
COP Tj = +7°C
8.14
6.85
Pdh Tj = 12°C
1.80 kW
1.60 kW
COP Tj = 12°C
7.70
6.64
Pdh Tj = Tbiv
7.00 kW
7.00 kW
COP Tj = Tbiv
5.79
4.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
7.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.79
4.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.95
0.96
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
18 W
15 W
PSB
10 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2378 kWh
3005 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
270 %
214 %
Prated
7.00 kW
7.00 kW
SCOP
6.95
5.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.30 kW
6.30 kW
COP Tj = -7°C
6.07
4.52
Pdh Tj = +2°C
3.90 kW
3.90 kW
COP Tj = +2°C
7.09
5.62
Pdh Tj = +7°C
2.50 kW
2.50 kW
COP Tj = +7°C
7.84
6.34
Pdh Tj = 12°C
1.80 kW
1.60 kW
COP Tj = 12°C
7.97
6.57
Pdh Tj = Tbiv
7.00 kW
7.00 kW
COP Tj = Tbiv
5.79
4.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
7.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.79
4.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.96
0.97
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
18 W
15 W
PSB
10 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2078 kWh
2611 kWh
Brine/Water Heat Pump
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
3.15 kW
2.78 kW
El input
0.67 kW
0.93 kW
COP
4.72
2.99
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
211 %
157 %
Prated
5.50 kW
5.50 kW
SCOP
5.48
4.13
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.40 kW
3.40 kW
COP Tj = -7°C
5.17
3.77
Cdh Tj = -7 °C
Pdh Tj = +2°C
2.10 kW
2.10 kW
COP Tj = +2°C
5.91
4.51
Cdh Tj = +2 °C
Pdh Tj = +7°C
1.40 kW
1.40 kW
COP Tj = +7°C
6.36
5.12
Cdh Tj = +7 °C
Pdh Tj = 12°C
1.30 kW
1.20 kW
COP Tj = 12°C
4.15
4.81
Cdh Tj = +12 °C
Pdh Tj = Tbiv
5.40 kW
5.50 kW
COP Tj = Tbiv
4.15
2.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.40 kW
5.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.15
2.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.970
0.980
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
10 W
7 W
PSB
7 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2481 kWh
3287 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
150 %
Prated
5.50 kW
5.50 kW
SCOP
5.20
3.95
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.00 kW
5.00 kW
COP Tj = -7°C
4.37
3.06
Pdh Tj = +2°C
3.10 kW
3.00 kW
COP Tj = +2°C
5.24
3.97
Pdh Tj = +7°C
2.00 kW
2.00 kW
COP Tj = +7°C
5.92
4.63
Pdh Tj = 12°C
1.30 kW
1.20 kW
COP Tj = 12°C
5.95
4.86
Pdh Tj = Tbiv
5.40 kW
5.40 kW
COP Tj = Tbiv
4.15
2.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.40 kW
5.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.15
2.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.99
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
10 W
7 W
PSB
7 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2188 kWh
2875 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
4.30 kW
3.82 kW
El input
0.66 kW
1.00 kW
COP
6.49
3.83
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
282 %
222 %
Prated
7.00 kW
7.00 kW
SCOP
7.25
5.75
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.30 kW
4.30 kW
COP Tj = -7°C
7.00
5.39
Pdh Tj = +2°C
2.70 kW
2.70 kW
COP Tj = +2°C
7.83
6.21
Pdh Tj = +7°C
1.80 kW
1.80 kW
COP Tj = +7°C
8.14
6.85
Pdh Tj = 12°C
1.80 kW
1.60 kW
COP Tj = 12°C
7.70
6.64
Pdh Tj = Tbiv
7.00 kW
7.00 kW
COP Tj = Tbiv
5.79
4.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
7.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.79
4.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.95
0.96
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
18 W
15 W
PSB
10 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2378 kWh
3005 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
270 %
214 %
Prated
7.00 kW
7.00 kW
SCOP
6.95
5.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.30 kW
6.30 kW
COP Tj = -7°C
6.07
4.52
Pdh Tj = +2°C
3.90 kW
3.90 kW
COP Tj = +2°C
7.09
5.62
Pdh Tj = +7°C
2.50 kW
2.50 kW
COP Tj = +7°C
7.84
6.34
Pdh Tj = 12°C
1.80 kW
1.60 kW
COP Tj = 12°C
7.97
6.57
Pdh Tj = Tbiv
7.00 kW
7.00 kW
COP Tj = Tbiv
5.79
4.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
7.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.79
4.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.96
0.97
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
18 W
15 W
PSB
10 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2078 kWh
2611 kWh
Brine/Water Heat Pump
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
3.15 kW
2.78 kW
El input
0.67 kW
0.93 kW
COP
4.72
2.99
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
211 %
157 %
Prated
5.50 kW
5.50 kW
SCOP
5.48
4.13
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.40 kW
3.40 kW
COP Tj = -7°C
5.17
3.77
Cdh Tj = -7 °C
Pdh Tj = +2°C
2.10 kW
2.10 kW
COP Tj = +2°C
5.91
4.51
Cdh Tj = +2 °C
Pdh Tj = +7°C
1.40 kW
1.40 kW
COP Tj = +7°C
6.36
5.12
Cdh Tj = +7 °C
Pdh Tj = 12°C
1.30 kW
1.20 kW
COP Tj = 12°C
4.15
4.81
Cdh Tj = +12 °C
Pdh Tj = Tbiv
5.40 kW
5.50 kW
COP Tj = Tbiv
4.15
2.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.40 kW
5.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.15
2.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.970
0.980
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
10 W
7 W
PSB
7 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2481 kWh
3287 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
150 %
Prated
5.50 kW
5.50 kW
SCOP
5.20
3.95
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.00 kW
5.00 kW
COP Tj = -7°C
4.37
3.06
Pdh Tj = +2°C
3.10 kW
3.00 kW
COP Tj = +2°C
5.24
3.97
Pdh Tj = +7°C
2.00 kW
2.00 kW
COP Tj = +7°C
5.92
4.63
Pdh Tj = 12°C
1.30 kW
1.20 kW
COP Tj = 12°C
5.95
4.86
Pdh Tj = Tbiv
5.40 kW
5.40 kW
COP Tj = Tbiv
4.15
2.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.40 kW
5.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.15
2.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.99
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
10 W
7 W
PSB
7 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2188 kWh
2875 kWh
Domestic Hot Water (DHW)
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
102 %
COP
2.55
Heating up time
02:23 h:min
Standby power input
50.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
245 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
102 %
COP
2.55
Heating up time
02:23 h:min
Standby power input
50.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
245 l
Water/Water Heat Pump
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
4.30 kW
3.82 kW
El input
0.66 kW
1.00 kW
COP
6.49
3.83
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
282 %
222 %
Prated
7.00 kW
7.00 kW
SCOP
7.25
5.75
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.30 kW
4.30 kW
COP Tj = -7°C
7.00
5.39
Pdh Tj = +2°C
2.70 kW
2.70 kW
COP Tj = +2°C
7.83
6.21
Pdh Tj = +7°C
1.80 kW
1.80 kW
COP Tj = +7°C
8.14
6.85
Pdh Tj = 12°C
1.80 kW
1.60 kW
COP Tj = 12°C
7.70
6.64
Pdh Tj = Tbiv
7.00 kW
7.00 kW
COP Tj = Tbiv
5.79
4.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
7.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.79
4.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.95
0.96
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
18 W
15 W
PSB
10 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2378 kWh
3005 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
270 %
214 %
Prated
7.00 kW
7.00 kW
SCOP
6.95
5.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.30 kW
6.30 kW
COP Tj = -7°C
6.07
4.52
Pdh Tj = +2°C
3.90 kW
3.90 kW
COP Tj = +2°C
7.09
5.62
Pdh Tj = +7°C
2.50 kW
2.50 kW
COP Tj = +7°C
7.84
6.34
Pdh Tj = 12°C
1.80 kW
1.60 kW
COP Tj = 12°C
7.97
6.57
Pdh Tj = Tbiv
7.00 kW
7.00 kW
COP Tj = Tbiv
5.79
4.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
7.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.79
4.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.96
0.97
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
18 W
15 W
PSB
10 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2078 kWh
2611 kWh
Domestic Hot Water (DHW)
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
117 %
COP
2.93
Heating up time
02:09 h:min
Standby power input
45.0 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
240 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
117 %
COP
2.93
Heating up time
02:09 h:min
Standby power input
45.0 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
240 l
Brine/Water Heat Pump
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
3.15 kW
2.78 kW
El input
0.67 kW
0.93 kW
COP
4.72
2.99
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
211 %
157 %
Prated
5.50 kW
5.50 kW
SCOP
5.48
4.13
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.40 kW
3.40 kW
COP Tj = -7°C
5.17
3.77
Cdh Tj = -7 °C
Pdh Tj = +2°C
2.10 kW
2.10 kW
COP Tj = +2°C
5.91
4.51
Cdh Tj = +2 °C
Pdh Tj = +7°C
1.40 kW
1.40 kW
COP Tj = +7°C
6.36
5.12
Cdh Tj = +7 °C
Pdh Tj = 12°C
1.30 kW
1.20 kW
COP Tj = 12°C
4.15
4.81
Cdh Tj = +12 °C
Pdh Tj = Tbiv
5.40 kW
5.50 kW
COP Tj = Tbiv
4.15
2.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.40 kW
5.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.15
2.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.970
0.980
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
10 W
7 W
PSB
7 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2481 kWh
3287 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
150 %
Prated
5.50 kW
5.50 kW
SCOP
5.20
3.95
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.00 kW
5.00 kW
COP Tj = -7°C
4.37
3.06
Pdh Tj = +2°C
3.10 kW
3.00 kW
COP Tj = +2°C
5.24
3.97
Pdh Tj = +7°C
2.00 kW
2.00 kW
COP Tj = +7°C
5.92
4.63
Pdh Tj = 12°C
1.30 kW
1.20 kW
COP Tj = 12°C
5.95
4.86
Pdh Tj = Tbiv
5.40 kW
5.40 kW
COP Tj = Tbiv
4.15
2.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.40 kW
5.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.15
2.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.99
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
10 W
7 W
PSB
7 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2188 kWh
2875 kWh
Domestic Hot Water (DHW)
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
102 %
COP
2.55
Heating up time
02:23 h:min
Standby power input
61.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
245 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
102 %
COP
2.55
Heating up time
02:23 h:min
Standby power input
61.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
245 l
Water/Water Heat Pump
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
4.30 kW
3.82 kW
El input
0.66 kW
1.00 kW
COP
6.49
3.83
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
282 %
222 %
Prated
7.00 kW
7.00 kW
SCOP
7.25
5.75
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.30 kW
4.30 kW
COP Tj = -7°C
7.00
5.39
Pdh Tj = +2°C
2.70 kW
2.70 kW
COP Tj = +2°C
7.83
6.21
Pdh Tj = +7°C
1.80 kW
1.80 kW
COP Tj = +7°C
8.14
6.85
Pdh Tj = 12°C
1.80 kW
1.60 kW
COP Tj = 12°C
7.70
6.64
Pdh Tj = Tbiv
7.00 kW
7.00 kW
COP Tj = Tbiv
5.79
4.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
7.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.79
4.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.95
0.96
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
18 W
15 W
PSB
10 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2378 kWh
3005 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
270 %
214 %
Prated
7.00 kW
7.00 kW
SCOP
6.95
5.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.30 kW
6.30 kW
COP Tj = -7°C
6.07
4.52
Pdh Tj = +2°C
3.90 kW
3.90 kW
COP Tj = +2°C
7.09
5.62
Pdh Tj = +7°C
2.50 kW
2.50 kW
COP Tj = +7°C
7.84
6.34
Pdh Tj = 12°C
1.80 kW
1.60 kW
COP Tj = 12°C
7.97
6.57
Pdh Tj = Tbiv
7.00 kW
7.00 kW
COP Tj = Tbiv
5.79
4.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
7.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.79
4.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.96
0.97
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
18 W
15 W
PSB
10 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2078 kWh
2611 kWh
Domestic Hot Water (DHW)
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
117 %
COP
2.93
Heating up time
02:09 h:min
Standby power input
55.0 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
240 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
117 %
COP
2.93
Heating up time
02:09 h:min
Standby power input
55.0 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
240 l
Brine/Water Heat Pump
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
3.15 kW
2.78 kW
El input
0.67 kW
0.93 kW
COP
4.72
2.99
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
211 %
157 %
Prated
5.50 kW
5.50 kW
SCOP
5.48
4.13
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.40 kW
3.40 kW
COP Tj = -7°C
5.17
3.77
Cdh Tj = -7 °C
Pdh Tj = +2°C
2.10 kW
2.10 kW
COP Tj = +2°C
5.91
4.51
Cdh Tj = +2 °C
Pdh Tj = +7°C
1.40 kW
1.40 kW
COP Tj = +7°C
6.36
5.12
Cdh Tj = +7 °C
Pdh Tj = 12°C
1.30 kW
1.20 kW
COP Tj = 12°C
4.15
4.81
Cdh Tj = +12 °C
Pdh Tj = Tbiv
5.40 kW
5.50 kW
COP Tj = Tbiv
4.15
2.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.40 kW
5.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.15
2.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.970
0.980
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
10 W
7 W
PSB
7 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2481 kWh
3287 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
150 %
Prated
5.50 kW
5.50 kW
SCOP
5.20
3.95
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.00 kW
5.00 kW
COP Tj = -7°C
4.37
3.06
Pdh Tj = +2°C
3.10 kW
3.00 kW
COP Tj = +2°C
5.24
3.97
Pdh Tj = +7°C
2.00 kW
2.00 kW
COP Tj = +7°C
5.92
4.63
Pdh Tj = 12°C
1.30 kW
1.20 kW
COP Tj = 12°C
5.95
4.86
Pdh Tj = Tbiv
5.40 kW
5.40 kW
COP Tj = Tbiv
4.15
2.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.40 kW
5.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.15
2.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.99
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
10 W
7 W
PSB
7 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2188 kWh
2875 kWh
Domestic Hot Water (DHW)
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
102 %
COP
2.55
Heating up time
02:23 h:min
Standby power input
50.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
245 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
102 %
COP
2.55
Heating up time
02:23 h:min
Standby power input
50.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
245 l
Water/Water Heat Pump
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
4.30 kW
3.82 kW
El input
0.66 kW
1.00 kW
COP
6.49
3.83
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
282 %
222 %
Prated
7.00 kW
7.00 kW
SCOP
7.25
5.75
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.30 kW
4.30 kW
COP Tj = -7°C
7.00
5.39
Pdh Tj = +2°C
2.70 kW
2.70 kW
COP Tj = +2°C
7.83
6.21
Pdh Tj = +7°C
1.80 kW
1.80 kW
COP Tj = +7°C
8.14
6.85
Pdh Tj = 12°C
1.80 kW
1.60 kW
COP Tj = 12°C
7.70
6.64
Pdh Tj = Tbiv
7.00 kW
7.00 kW
COP Tj = Tbiv
5.79
4.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
7.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.79
4.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.95
0.96
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
18 W
15 W
PSB
10 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2378 kWh
3005 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
270 %
214 %
Prated
7.00 kW
7.00 kW
SCOP
6.95
5.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.30 kW
6.30 kW
COP Tj = -7°C
6.07
4.52
Pdh Tj = +2°C
3.90 kW
3.90 kW
COP Tj = +2°C
7.09
5.62
Pdh Tj = +7°C
2.50 kW
2.50 kW
COP Tj = +7°C
7.84
6.34
Pdh Tj = 12°C
1.80 kW
1.60 kW
COP Tj = 12°C
7.97
6.57
Pdh Tj = Tbiv
7.00 kW
7.00 kW
COP Tj = Tbiv
5.79
4.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
7.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.79
4.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.96
0.97
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
18 W
15 W
PSB
10 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2078 kWh
2611 kWh
Domestic Hot Water (DHW)
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
117 %
COP
2.93
Heating up time
02:09 h:min
Standby power input
45.0 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
240 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
117 %
COP
2.93
Heating up time
02:09 h:min
Standby power input
45.0 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
240 l
Brine/Water Heat Pump
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
3.15 kW
2.78 kW
El input
0.67 kW
0.93 kW
COP
4.72
2.99
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
211 %
157 %
Prated
5.50 kW
5.50 kW
SCOP
5.48
4.13
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.40 kW
3.40 kW
COP Tj = -7°C
5.17
3.77
Cdh Tj = -7 °C
Pdh Tj = +2°C
2.10 kW
2.10 kW
COP Tj = +2°C
5.91
4.51
Cdh Tj = +2 °C
Pdh Tj = +7°C
1.40 kW
1.40 kW
COP Tj = +7°C
6.36
5.12
Cdh Tj = +7 °C
Pdh Tj = 12°C
1.30 kW
1.20 kW
COP Tj = 12°C
4.15
4.81
Cdh Tj = +12 °C
Pdh Tj = Tbiv
5.40 kW
5.50 kW
COP Tj = Tbiv
4.15
2.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.40 kW
5.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.15
2.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.970
0.980
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
10 W
7 W
PSB
7 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2481 kWh
3287 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
150 %
Prated
5.50 kW
5.50 kW
SCOP
5.20
3.95
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.00 kW
5.00 kW
COP Tj = -7°C
4.37
3.06
Pdh Tj = +2°C
3.10 kW
3.00 kW
COP Tj = +2°C
5.24
3.97
Pdh Tj = +7°C
2.00 kW
2.00 kW
COP Tj = +7°C
5.92
4.63
Pdh Tj = 12°C
1.30 kW
1.20 kW
COP Tj = 12°C
5.95
4.86
Pdh Tj = Tbiv
5.40 kW
5.40 kW
COP Tj = Tbiv
4.15
2.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.40 kW
5.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.15
2.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.99
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
10 W
7 W
PSB
7 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2188 kWh
2875 kWh
Domestic Hot Water (DHW)
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
102 %
COP
2.55
Heating up time
02:23 h:min
Standby power input
61.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
245 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
102 %
COP
2.55
Heating up time
02:23 h:min
Standby power input
61.0 W
Reference hot water temperature
50.0 °C
Mixed water at 40°C
245 l
Water/Water Heat Pump
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
4.30 kW
3.82 kW
El input
0.66 kW
1.00 kW
COP
6.49
3.83
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
282 %
222 %
Prated
7.00 kW
7.00 kW
SCOP
7.25
5.75
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.30 kW
4.30 kW
COP Tj = -7°C
7.00
5.39
Pdh Tj = +2°C
2.70 kW
2.70 kW
COP Tj = +2°C
7.83
6.21
Pdh Tj = +7°C
1.80 kW
1.80 kW
COP Tj = +7°C
8.14
6.85
Pdh Tj = 12°C
1.80 kW
1.60 kW
COP Tj = 12°C
7.70
6.64
Pdh Tj = Tbiv
7.00 kW
7.00 kW
COP Tj = Tbiv
5.79
4.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
7.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.79
4.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.95
0.96
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
18 W
15 W
PSB
10 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2378 kWh
3005 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
270 %
214 %
Prated
7.00 kW
7.00 kW
SCOP
6.95
5.55
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.30 kW
6.30 kW
COP Tj = -7°C
6.07
4.52
Pdh Tj = +2°C
3.90 kW
3.90 kW
COP Tj = +2°C
7.09
5.62
Pdh Tj = +7°C
2.50 kW
2.50 kW
COP Tj = +7°C
7.84
6.34
Pdh Tj = 12°C
1.80 kW
1.60 kW
COP Tj = 12°C
7.97
6.57
Pdh Tj = Tbiv
7.00 kW
7.00 kW
COP Tj = Tbiv
5.79
4.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.00 kW
7.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.79
4.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.96
0.97
WTOL
65 °C
65 °C
Poff
2 W
2 W
PTO
18 W
15 W
PSB
10 W
7 W
PCK
9 W
9 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2078 kWh
2611 kWh
Domestic Hot Water (DHW)
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
117 %
COP
2.93
Heating up time
02:09 h:min
Standby power input
55.0 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
240 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
117 %
COP
2.93
Heating up time
02:09 h:min
Standby power input
55.0 W
Reference hot water temperature
49.0 °C
Mixed water at 40°C
240 l