Certificate holders

Subtype

TTF 10 basic

Certificate Holder
tecalor GmbH
Fürstenbergerstr. 77
37603 Holzminden
Germany
Registration number
011-1W0046
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
TTF 10 basic
Driving energy
n/a
Heat Pump Type
Brine/Water
Refrigerant
R410A
Mass of Refrigerant

2,600 kg

Certification Date
28.10.2016
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 2

Models

TTF 10 basic, all climates
Configure model
Model name
TTF 10 basic, all climates
Application
Heating (low temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Heat output

9.70 kW

El input

2.22 kW

COP

4.37

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Sound power level indoor

51 dB(A)

EN 14825

ηs

190 %

Prated

10.00 kW

SCOP

4.94

Tbiv

-10 °C

TOL

-20 °C

Pdh Tj = -7°C

9.70 kW

COP Tj = -7°C

4.44

Cdh Tj = -7 °C

0.90

Pdh Tj = +2°C

9.80 kW

COP Tj = +2°C

4.85

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

10.00 kW

COP Tj = +7°C

5.28

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

10.10 kW

COP Tj = 12°C

5.78

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

9.70 kW

COP Tj = Tbiv

4.37

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.37

WTOL

60 °C

Poff

0 W

PTO

78 W

PSB

3 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

4053 kWh

Warmer Climate

EN 14825

ηs

190 %

Prated

10.00 kW

SCOP

4.95

Tbiv

2 °C

TOL

0 °C

Pdh Tj = +2°C

9.70 kW

COP Tj = +2°C

4.37

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

9.80 kW

COP Tj = +7°C

4.76

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

10.00 kW

COP Tj = 12°C

5.44

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

9.70 kW

COP Tj = Tbiv

4.37

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.37

WTOL

60 °C

Poff

0 W

PTO

78 W

PSB

3 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

2617 kWh

Colder Climate

EN 14825

ηs

199 %

Prated

12.00 kW

SCOP

5.17

Tbiv

-15 °C

TOL

-22 °C

Pdh Tj = -7°C

9.90 kW

COP Tj = -7°C

5.07

Cdh Tj = -7 °C

0.90

Pdh Tj = +2°C

10.00 kW

COP Tj = +2°C

5.41

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

10.10 kW

COP Tj = +7°C

5.70

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

10.10 kW

COP Tj = 12°C

5.75

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

9.90 kW

COP Tj = Tbiv

4.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.93

WTOL

60 °C

Poff

0 W

PTO

78 W

PSB

3 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

2.40 kW

Annual energy consumption Qhe

5768 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.90

COP Tj = -15°C (if TOL<-20°C)

4.93

Cdh Tj = -15 °C

0.90

TTF 10 basic, average climates
Configure model
Model name
TTF 10 basic, average climates
Application
Heating (medium temp)
Units
Indoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.70 kW

8.57 kW

El input

2.22 kW

3.67 kW

COP

4.37

2.34

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

114 %

Prated

10.00 kW

9.00 kW

SCOP

4.94

3.06

Tbiv

-10 °C

-10 °C

TOL

-20 °C

-10 °C

Pdh Tj = -7°C

9.70 kW

8.70 kW

COP Tj = -7°C

4.44

2.46

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

9.80 kW

9.10 kW

COP Tj = +2°C

4.85

2.99

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

10.00 kW

9.30 kW

COP Tj = +7°C

5.28

3.42

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

10.10 kW

9.50 kW

COP Tj = 12°C

5.78

3.95

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

9.70 kW

8.60 kW

COP Tj = Tbiv

4.37

2.34

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.70 kW

8.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.37

2.34

WTOL

60 °C

60 °C

Poff

0 W

0 W

PTO

78 W

78 W

PSB

3 W

3 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4053 kWh

5788 kWh