Certificate holders

Subtype

F2120-12

Certificate Holder
Nibe AB
Box 14
S-28521 Markaryd
Sweden
Reg. No.
012-030
Certification Body
RISE CERT
Name of testing laboratory
DTI
Subtype title
F2120-12
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
HFC-410a
Mass Of Refrigerant

2,600 kg

Certification Date
n/a
Testing basis
n/a
Generate PDF Export model CSV Download certificate

Models

F2120-12 1x230
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.54 kW

3.64 kW

El input

0.69 kW

1.18 kW

COP

5.12

3.08

Indoor water flow rate

0.61 m³/h

0.39 m³/h

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

148 %

Prated

8.00 kW

8.30 kW

SCOP

4.82

3.27

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.10 kW

7.30 kW

COP Tj = -7°C

3.05

2.39

Pdh Tj = +2°C

4.70 kW

4.70 kW

COP Tj = +2°C

4.57

3.85

Pdh Tj = +7°C

3.10 kW

2.90 kW

COP Tj = +7°C

5.86

4.48

Pdh Tj = 12°C

3.60 kW

3.30 kW

COP Tj = 12°C

7.22

5.30

Pdh Tj = Tbiv

7.10 kW

7.30 kW

COP Tj = Tbiv

2.95

2.28

Pdh Tj = TOL

7.30 kW

7.80 kW

COP Tj = TOL

3.05

2.39

Cdh

0.99

0.99

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

7 W

7 W

PSB

25 W

25 W

PCK

37 W

37 W

Supplementary Heater: Type of energy input

electricity

electricity

Supplementary Heater: PSUP

0.70 kW

0.50 kW

Annual energy consumption Qhe

3409 kWh

4529 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

130 %

Prated

9.30 kW

9.80 kW

SCOP

4.05

3.32

Tbiv

-12 °C

-12 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.70 kW

5.90 kW

COP Tj = -7°C

3.33

2.74

Pdh Tj = +2°C

3.40 kW

3.60 kW

COP Tj = +2°C

5.18

4.14

Pdh Tj = +7°C

2.90 kW

2.90 kW

COP Tj = +7°C

5.73

4.70

Pdh Tj = 12°C

3.30 kW

3.30 kW

COP Tj = 12°C

6.44

5.41

Pdh Tj = Tbiv

6.90 kW

7.30 kW

COP Tj = Tbiv

2.99

2.47

Pdh Tj = TOL

5.20 kW

6.00 kW

COP Tj = TOL

2.31

1.84

Cdh

0.99

0.99

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

7 W

7 W

PSB

25 W

25 W

PCK

37 W

37 W

Supplementary Heater: Type of energy input

electricity

electricity

Supplementary Heater: PSUP

4.10 kW

3.80 kW

Annual energy consumption Qhe

5666 kWh

7239 kWh

F2120-12 3x400
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.54 kW

3.64 kW

El input

0.69 kW

1.18 kW

COP

5.12

3.08

Indoor water flow rate

0.61 m³/h

0.39 m³/h

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

148 %

Prated

8.00 kW

8.30 kW

SCOP

4.82

3.27

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.10 kW

7.30 kW

COP Tj = -7°C

3.05

2.39

Pdh Tj = +2°C

4.70 kW

4.70 kW

COP Tj = +2°C

4.57

3.85

Pdh Tj = +7°C

3.10 kW

2.90 kW

COP Tj = +7°C

5.86

4.48

Pdh Tj = 12°C

3.60 kW

3.30 kW

COP Tj = 12°C

7.22

5.30

Pdh Tj = Tbiv

7.10 kW

7.30 kW

COP Tj = Tbiv

2.95

2.28

Pdh Tj = TOL

7.30 kW

7.80 kW

COP Tj = TOL

3.05

2.39

Cdh

0.99

0.99

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

7 W

7 W

PSB

25 W

25 W

PCK

37 W

37 W

Supplementary Heater: Type of energy input

electricity

electricity

Supplementary Heater: PSUP

0.70 kW

0.50 kW

Annual energy consumption Qhe

3409 kWh

4529 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

130 %

Prated

9.30 kW

9.80 kW

SCOP

4.05

3.32

Tbiv

-12 °C

-12 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.70 kW

5.90 kW

COP Tj = -7°C

3.33

2.74

Pdh Tj = +2°C

3.40 kW

3.60 kW

COP Tj = +2°C

5.18

4.14

Pdh Tj = +7°C

2.90 kW

2.90 kW

COP Tj = +7°C

5.73

4.70

Pdh Tj = 12°C

3.30 kW

3.30 kW

COP Tj = 12°C

6.44

5.41

Pdh Tj = Tbiv

6.90 kW

7.30 kW

COP Tj = Tbiv

2.99

2.47

Pdh Tj = TOL

5.20 kW

6.00 kW

COP Tj = TOL

2.31

1.84

Cdh

0.99

0.99

WTOL

65 °C

65 °C

Poff

25 W

25 W

PTO

7 W

7 W

PSB

25 W

25 W

PCK

37 W

37 W

Supplementary Heater: Type of energy input

electricity

electricity

Supplementary Heater: PSUP

4.10 kW

3.80 kW

Annual energy consumption Qhe

5666 kWh

7239 kWh