Vitocal 2xx-A ODU3
Heat Pump Type: Outdoor Air/Water
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
7.01 kW
7.93 kW
El input
1.49 kW
2.73 kW
COP
4.69
2.90
EN 14825
Pdesignh
9.32 kW
Rated airflow rate
4500 m³/h
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
39 dB(A)
39 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
129 %
Prated
9.32 kW
9.35 kW
SCOP
4.47
3.29
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
8.25 kW
8.27 kW
COP Tj = -7°C
3.24
2.26
Pdh Tj = +2°C
5.32 kW
6.07 kW
COP Tj = +2°C
4.32
3.15
Pdh Tj = +7°C
6.60 kW
5.37 kW
COP Tj = +7°C
5.81
4.21
Pdh Tj = 12°C
6.63 kW
6.41 kW
COP Tj = 12°C
7.51
5.70
Pdh Tj = Tbiv
8.25 kW
8.27 kW
COP Tj = Tbiv
3.24
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.51 kW
8.04 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.90
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.99
WTOL
60 °C
60 °C
Poff
50 W
50 W
PTO
0 W
0 W
PSB
25 W
25 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.86 kW
1.36 kW
Annual energy consumption Qhe
4314 kWh