Certificate holders

Single View for Model

Subtype

Vitocal 2xx-A ODU3

Heat Pump Type: Outdoor Air/Water

Applicant

Viessmann Wärmepumpen GmbH
Viessmannstr. 1
35107 Allendorf/Eder
Germany

Certification Body

DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Alboinstr. 56
12103 Berlin
Germany

Vitocal 200-A AWO-M 201.A10

Configure model
Model name
Vitocal 200-A AWO-M 201.A10
Model-ID (internal)
Z015204
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General data
Power supply
1x230V 50Hz
Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.01 kW

7.93 kW

El input

1.49 kW

2.73 kW

COP

4.69

2.90

Indoor water flow rate

1.40 m³/h

1.40 m³/h

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

129 %

Prated

9.32 kW

9.35 kW

SCOP

4.47

3.29

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

8.25 kW

8.27 kW

COP Tj = -7°C

3.24

2.26

Cdh

n/a

n/a

Pdh Tj = +2°C

5.32 kW

6.07 kW

COP Tj = +2°C

4.32

3.15

Cdh

n/a

n/a

Pdh Tj = +7°C

6.60 kW

5.37 kW

COP Tj = +7°C

5.81

4.21

Cdh

n/a

n/a

Pdh Tj = 12°C

6.63 kW

6.41 kW

COP Tj = 12°C

7.51

5.70

Cdh

n/a

n/a

Pdh Tj = Tbiv

8.25 kW

8.27 kW

COP Tj = Tbiv

3.24

2.26

Pdh Tj = TOL

7.51 kW

8.04 kW

COP Tj = TOL

2.90

2.04

WTOL

60 °C

60 °C

Poff

50 W

50 W

PTO

0 W

0 W

PSB

25 W

25 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electrical

electrical

Supplementary Heater: PSUP

1.86 kW

1.36 kW

Annual energy consumption Qhe

4314 kWh

5867 kWh