Certificate holders

Single View for Model

Subtype

CTC EcoAir 408

Heat Pump Type: Outdoor Air/Water

Applicant

CTC AB
Box 309, Näsvägen
SE-341 26 Ljungby
Sweden

Certification Body

RISE CERT
IEA Heat Pump Centre
S-50115 Boras
Sweden

CTC EcoAir 408 1x230V

Configure model
Model name
CTC EcoAir 408 1x230V
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.83 kW

7.08 kW

El input

1.62 kW

2.28 kW

COP

4.83

3.11

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

133 %

106 %

Prated

4.82 kW

5.66 kW

SCOP

3.40

2.70

Tbiv

-14 °C

-11 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.80 kW

4.60 kW

COP Tj = -7°C

3.22

2.49

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

6.30 kW

5.70 kW

COP Tj = +2°C

4.19

3.25

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

8.00 kW

7.70 kW

COP Tj = +7°C

5.42

4.40

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

9.80 kW

9.60 kW

COP Tj = 12°C

6.55

5.50

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

3.70 kW

4.02 kW

COP Tj = Tbiv

2.55

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.70 kW

2.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.90

1.24

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.990

WTOL

65 °C

65 °C

Poff

18 W

18 W

PTO

22 W

7 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.10 kW

3.30 kW

Annual energy consumption Qhe

3494 kWh

5143 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.67

3.41

COP Tj = -15°C (if TOL<-20°C)

2.55

1.85

Cdh Tj = -15 °C

0.970

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

154 %

118 %

Prated

6.26 kW

6.37 kW

SCOP

3.90

3.00

Tbiv

-5 °C

-4 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.70 kW

4.50 kW

COP Tj = -7°C

3.07

2.21

Pdh Tj = +2°C

6.20 kW

5.50 kW

COP Tj = +2°C

4.03

2.98

Pdh Tj = +7°C

8.00 kW

7.60 kW

COP Tj = +7°C

5.28

4.09

Pdh Tj = 12°C

9.80 kW

9.00 kW

COP Tj = 12°C

6.58

5.31

Pdh Tj = Tbiv

5.10 kW

4.90 kW

COP Tj = Tbiv

3.30

2.51

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.30 kW

4.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.91

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.97

0.99

WTOL

65 °C

65 °C

Poff

18 W

18 W

PTO

22 W

7 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.90 kW

2.40 kW

Annual energy consumption Qhe

3297 kWh

4343 kWh