Bosch Compress 7000iAW 9 OR and IR, Compress 6000 AW-9
Heat Pump Type: Outdoor Air/Water
EN 14511-2
Low temperature
Medium temperature
Heat output
3.32 kW
2.84 kW
El input
0.67 kW
1.07 kW
COP
4.93
2.65
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
199 %
143 %
Prated
7.00 kW
6.00 kW
SCOP
5.05
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.30 kW
5.10 kW
COP Tj = -7°C
3.00
2.23
Cdh
n/a
n/a
Pdh Tj = +2°C
4.00 kW
3.10 kW
COP Tj = +2°C
4.86
3.49
Cdh
n/a
n/a
Pdh Tj = +7°C
2.70 kW
2.80 kW
COP Tj = +7°C
6.80
4.95
Cdh
n/a
n/a
Pdh Tj = 12°C
1.80 kW
3.50 kW
COP Tj = 12°C
9.63
7.73
Cdh
n/a
n/a
Pdh Tj = Tbiv
7.30 kW
6.10 kW
COP Tj = Tbiv
2.56
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.30 kW
6.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.56
1.84
WTOL
60 °C
60 °C
Poff
17 W
17 W
PTO
17 W
17 W
PSB
17 W
17 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electric
Electric
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3161 kWh
3585 kWh
EN 16147
Declared load profile
L
Efficiency ηDHW
97 %
COP
2.40
Heating up time
02:44 h:min
Standby power input
58.7 W
Reference hot water temperature
55.6 °C
Mixed water at 40°C
284 l