Bosch Compress 3000 AWS-8
Heat Pump Type: Outdoor Air/Water
EN 14511-2
Low temperature
Medium temperature
Heat output
5.41 kW
3.99 kW
El input
1.13 kW
1.47 kW
COP
4.80
2.72
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
150 %
125 %
Prated
7.00 kW
6.00 kW
SCOP
3.83
3.20
Tbiv
-10 °C
-10 °C
TOL
-15 °C
-15 °C
Pdh Tj = -7°C
6.40 kW
5.30 kW
COP Tj = -7°C
2.65
2.11
Cdh
n/a
n/a
Pdh Tj = +2°C
3.90 kW
3.20 kW
COP Tj = +2°C
3.61
3.10
Cdh
n/a
n/a
Pdh Tj = +7°C
3.60 kW
3.60 kW
COP Tj = +7°C
5.71
4.70
Cdh
n/a
n/a
Pdh Tj = 12°C
3.60 kW
3.60 kW
COP Tj = 12°C
5.71
5.00
Cdh
n/a
n/a
Pdh Tj = Tbiv
7.20 kW
6.00 kW
COP Tj = Tbiv
2.51
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.70 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.41
2.00
WTOL
57 °C
57 °C
Poff
11 W
11 W
PTO
51 W
51 W
PSB
11 W
11 W
PCK
100 W
100 W
Supplementary Heater: Type of energy input
Electric
Electric
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3879 kWh
3890 kWh
EN 16147
Declared load profile
L
Efficiency ηDHW
105 %
COP
2.49
Heating up time
02:08 h:min
Standby power input
44.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
257 l