F2120-8
Heat Pump Type: Outdoor Air/Water
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
3.57 kW
3.75 kW
El input
0.78 kW
1.23 kW
COP
4.57
3.05
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
158 %
130 %
Prated
6.80 kW
7.40 kW
SCOP
4.02
3.32
Tbiv
-12 °C
-12 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.10 kW
4.50 kW
COP Tj = -7°C
3.30
2.74
Pdh Tj = +2°C
2.60 kW
2.70 kW
COP Tj = +2°C
5.20
4.10
Pdh Tj = +7°C
2.90 kW
2.90 kW
COP Tj = +7°C
5.52
4.65
Pdh Tj = 12°C
3.30 kW
3.30 kW
COP Tj = 12°C
6.25
5.31
Pdh Tj = Tbiv
5.00 kW
5.50 kW
COP Tj = Tbiv
3.00
2.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.80 kW
4.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.30
1.85
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
10 W
10 W
PSB
25 W
25 W
PCK
37 W
37 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.10 kW
3.10 kW
Annual energy consumption Qhe
4182 kWh
5524 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
189 %
147 %
Prated
5.90 kW
6.30 kW
SCOP
4.80
3.67
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.20 kW
5.50 kW
COP Tj = -7°C
3.25
2.48
Pdh Tj = +2°C
4.00 kW
4.10 kW
COP Tj = +2°C
4.91
3.80
Pdh Tj = +7°C
2.90 kW
2.90 kW
COP Tj = +7°C
5.60
4.45
Pdh Tj = 12°C
3.30 kW
3.30 kW
COP Tj = 12°C
6.40
5.26
Pdh Tj = Tbiv
5.20 kW
5.50 kW
COP Tj = Tbiv
3.25
2.48
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.30 kW
5.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.12
2.34
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
10 W
10 W
PSB
25 W
25 W
PCK
37 W
37 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.60 kW
0.60 kW
Annual energy consumption Qhe
4182 kWh
5524 kWh