Certificate

15. Yutaki S80 4.0HP (tri)

Johnson Controls-Hitachi AirConditioning Spain
Ronda Shimizu, 1. Pol. Ind. Can Torrella
08233 Vacarisses, Barcelona
Spain
041-K002-15
BRE Energy & Communications Division
CEIS
15. Yutaki S80 4.0HP (tri)
Outdoor Air/Water
HFC-410a
3,300kg
n/a
 
RAS-4WHNPE RWH-4.0NFWE - Type 2
General Data
3x400V 50Hz
Heating
EN 14511-2
Low temperatureMedium temperature
n/an/a
2.20kW3.31kW
5.003.32
1.89m3/h1.18m3/h
EN 14511-4
passed
passed
n/a
Average Climate
EN 12102-1
57dB(A)57dB(A)
61dB(A)61dB(A)
EN 14825
Low temperatureMedium temperature
183%140%
11.00kW11.00kW
4.653.58
-7°C-10°C
-10°C-10°C
9.60kW9.73kW
2.742.30
n/an/a
5.84kW5.92kW
5.203.60
n/an/a
3.76kW3.81kW
5.804.70
n/an/a
3.70kW3.60kW
6.406.00
n/an/a
9.60kW11.00kW
2.742.20
10.50kW11.00kW
2.652.20
55°C55°C
44W44W
0W0W
44W44W
0W0W
electricityelectricity
0.50kW0.00kW
4828kWh6360kWh
RAS-4WHNPE RWH-4.0NFE - Type 1
General Data
3x400V 50Hz
Heating
EN 14511-2
Low temperatureMedium temperature
n/an/a
2.20kW3.31kW
5.003.32
1.89m3/h1.18m3/h
EN 14511-4
passed
passed
n/a
Average Climate
EN 12102-1
57dB(A)57dB(A)
61dB(A)61dB(A)
EN 14825
Low temperatureMedium temperature
183%140%
11.00kW11.00kW
4.653.58
-7°C-10°C
-10°C-10°C
9.60kW9.73kW
2.742.30
n/an/a
5.84kW5.92kW
5.203.60
n/an/a
3.76kW3.81kW
5.804.70
n/an/a
3.70kW3.60kW
6.406.00
n/an/a
9.60kW11.00kW
2.742.20
10.50kW11.00kW
2.652.20
55°C55°C
44W44W
0W0W
44W44W
0W0W
electricityelectricity
0.50kW0.00kW
4828kWh6360kWh