3,800 kg
Brine/Water Heat Pump
Chauffage
EN 14511-4
Starting and operating test
réussi
EN 14511-2
Basse température
Moyenne température
COP
4.40
3.00
Climat plus froid
EN 14825
Basse température
Moyenne température
ηs
203 %
158 %
Prated
45.00 kW
42.00 kW
SCOP
5.30
4.10
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
27.15 kW
25.15 kW
COP Tj = -7°C
4.93
3.68
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
16.45 kW
15.47 kW
COP Tj = +2°C
5.54
4.50
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
10.89 kW
9.95 kW
COP Tj = +7°C
6.28
5.36
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
7.77 kW
7.74 kW
COP Tj = 12°C
6.22
5.40
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
42.87 kW
40.11 kW
COP Tj = Tbiv
4.02
2.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
42.87 kW
40.11 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.02
2.83
WTOL
65 °C
65 °C
Poff
8 W
8 W
PTO
0 W
0 W
PSB
18 W
18 W
PCK
20 W
20 W
Climat moyen
EN 14825
Basse température
Moyenne température
ηs
192 %
152 %
Prated
45.00 kW
42.00 kW
SCOP
5.00
4.00
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
39.50 kW
36.50 kW
COP Tj = -7°C
4.24
3.13
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
26.43 kW
26.59 kW
COP Tj = +2°C
4.82
3.87
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
15.39 kW
13.32 kW
COP Tj = +7°C
5.61
4.66
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
7.81 kW
7.78 kW
COP Tj = 12°C
6.51
5.41
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
42.90 kW
40.11 kW
COP Tj = Tbiv
4.02
2.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
42.90 kW
40.11 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.02
2.83
WTOL
65 °C
65 °C
Poff
8 W
8 W
PTO
0 W
0 W
PSB
18 W
18 W
PCK
20 W
20 W
Water/Water Heat Pump
Chauffage
EN 14511-4
Starting and operating test
réussi
EN 14511-2
Basse température
Moyenne température
COP
5.52
3.81
Climat plus froid
EN 14825
Basse température
Moyenne température
ηs
252 %
204 %
Prated
58.00 kW
52.00 kW
SCOP
6.50
5.29
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
35.10 kW
31.50 kW
COP Tj = -7°C
6.13
4.50
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
21.50 kW
19.20 kW
COP Tj = +2°C
7.00
6.20
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
13.80 kW
12.50 kW
COP Tj = +7°C
7.00
6.20
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
9.00 kW
8.00 kW
COP Tj = 12°C
7.00
6.20
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
57.79 kW
51.90 kW
COP Tj = Tbiv
5.04
3.53
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
57.79 kW
51.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.04
3.53
WTOL
65 °C
65 °C
Poff
8 W
8 W
PTO
30 W
20 W
PSB
18 W
18 W
PCK
20 W
20 W
Climat moyen
EN 14825
Basse température
Moyenne température
ηs
244 %
194 %
Prated
58.00 kW
52.00 kW
SCOP
6.30
5.05
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
51.30 kW
46.00 kW
COP Tj = -7°C
5.20
3.65
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
33.97 kW
27.75 kW
COP Tj = +2°C
6.13
4.90
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
20.10 kW
18.00 kW
COP Tj = +7°C
7.30
6.34
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
9.00 kW
8.00 kW
COP Tj = 12°C
7.50
6.34
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
57.80 kW
51.93 kW
COP Tj = Tbiv
5.04
3.53
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
57.80 kW
51.93 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.04
3.53
WTOL
65 °C
65 °C
Poff
8 W
8 W
PTO
30 W
20 W
PSB
18 W
18 W
PCK
20 W
20 W