4,500 kg
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
50.40 kW
47.40 kW
Entrada EI
13.23 kW
17.69 kW
COP
3.81
2.68
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
69 dB(A)
69 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
171 %
137 %
Prated
39.00 kW
35.30 kW
SCOP
4.37
3.51
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
34.50 kW
31.23 kW
COP Tj = -7°C
2.53
2.11
Cdh Tj = -7 °C
Pdh Tj = +2°C
21.00 kW
19.80 kW
COP Tj = +2°C
4.28
3.39
Cdh Tj = +2 °C
Pdh Tj = +7°C
20.39 kW
19.40 kW
COP Tj = +7°C
6.62
5.24
Cdh Tj = +7 °C
Pdh Tj = 12°C
20.48 kW
22.04 kW
COP Tj = 12°C
6.89
6.70
Cdh Tj = +12 °C
Pdh Tj = Tbiv
34.50 kW
31.23 kW
COP Tj = Tbiv
2.53
2.11
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
38.71 kW
35.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.27
1.70
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
35 °C
55 °C
Poff
130 W
130 W
PTO
200 W
200 W
PSB
130 W
130 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
n/a
n/a
Calentador suplementario: PSUP
0.29 kW
0.30 kW
Consumo annual de energia QHE
18452 kWh
20744 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
55.80 kW
51.20 kW
Entrada EI
14.76 kW
19.62 kW
COP
3.78
2.61
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
69 dB(A)
69 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
169 %
136 %
Prated
47.82 kW
40.70 kW
SCOP
4.29
3.48
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
42.30 kW
36.00 kW
COP Tj = -7°C
2.47
1.95
Cdh Tj = -7 °C
Pdh Tj = +2°C
25.13 kW
22.20 kW
COP Tj = +2°C
4.15
3.38
Cdh Tj = +2 °C
Pdh Tj = +7°C
20.40 kW
19.40 kW
COP Tj = +7°C
6.62
5.24
Cdh Tj = +7 °C
Pdh Tj = 12°C
20.48 kW
22.04 kW
COP Tj = 12°C
6.89
6.70
Cdh Tj = +12 °C
Pdh Tj = Tbiv
42.30 kW
36.00 kW
COP Tj = Tbiv
2.47
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
41.60 kW
36.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.24
1.70
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
35 °C
55 °C
Poff
130 W
130 W
PTO
220 W
220 W
PSB
130 W
130 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
n/a
n/a
Calentador suplementario: PSUP
6.22 kW
4.00 kW
Consumo annual de energia QHE
22803 kWh
24069 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
61.00 kW
55.70 kW
Entrada EI
16.35 kW
21.76 kW
COP
3.73
2.56
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
69 dB(A)
69 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
166 %
133 %
Prated
52.45 kW
42.66 kW
SCOP
4.22
3.41
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
46.40 kW
37.40 kW
COP Tj = -7°C
2.41
1.79
Cdh Tj = -7 °C
Pdh Tj = +2°C
28.00 kW
24.60 kW
COP Tj = +2°C
4.04
3.35
Cdh Tj = +2 °C
Pdh Tj = +7°C
20.40 kW
19.40 kW
COP Tj = +7°C
6.62
5.24
Cdh Tj = +7 °C
Pdh Tj = 12°C
20.48 kW
22.04 kW
COP Tj = 12°C
6.89
6.70
Cdh Tj = +12 °C
Pdh Tj = Tbiv
46.40 kW
37.74 kW
COP Tj = Tbiv
2.41
1.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
41.60 kW
36.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.24
1.70
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
35 °C
55 °C
Poff
130 W
130 W
PTO
230 W
230 W
PSB
130 W
130 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
n/a
n/a
Calentador suplementario: PSUP
10.85 kW
5.96 kW
Consumo annual de energia QHE
25346 kWh
25661 kWh