1,000 kg
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
16.00 kW
14.00 kW
Entrada EI
3.64 kW
5.00 kW
COP
4.40
2.80
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
59 dB(A)
59 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
189 %
141 %
Prated
12.00 kW
11.00 kW
SCOP
4.80
3.60
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.41 kW
9.73 kW
COP Tj = -7°C
3.00
2.17
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.20 kW
5.92 kW
COP Tj = +2°C
4.70
3.54
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.30 kW
4.30 kW
COP Tj = +7°C
6.45
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.70
6.25
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.00 kW
11.00 kW
COP Tj = Tbiv
2.50
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
11.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.50
1.90
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
74 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
5164 kWh
6313 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
14.00 kW
13.00 kW
Entrada EI
3.11 kW
4.48 kW
COP
4.50
2.90
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
57 dB(A)
57 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
191 %
143 %
Prated
11.70 kW
10.50 kW
SCOP
4.85
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.35 kW
9.29 kW
COP Tj = -7°C
3.05
2.26
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.10 kW
5.50 kW
COP Tj = +2°C
4.74
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.40 kW
4.30 kW
COP Tj = +7°C
6.50
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.80
6.30
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.70 kW
10.50 kW
COP Tj = Tbiv
2.55
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.70 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.55
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
9 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4986 kWh
5939 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.61 kW
4.07 kW
COP
4.60
2.95
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
56 dB(A)
56 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
187 %
143 %
Prated
11.00 kW
10.50 kW
SCOP
4.75
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.73 kW
9.29 kW
COP Tj = -7°C
3.06
2.26
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.92 kW
5.50 kW
COP Tj = +2°C
4.75
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.20 kW
4.30 kW
COP Tj = +7°C
6.00
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.80
6.30
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.00 kW
10.50 kW
COP Tj = Tbiv
2.60
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.00 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.60
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
73 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4783 kWh
5940 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
16.00 kW
14.00 kW
Entrada EI
3.64 kW
5.00 kW
COP
4.40
2.80
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
59 dB(A)
59 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
189 %
141 %
Prated
12.00 kW
11.00 kW
SCOP
4.80
3.60
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.40 kW
9.73 kW
COP Tj = -7°C
3.00
2.17
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.20 kW
5.92 kW
COP Tj = +2°C
4.70
3.54
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.30 kW
4.30 kW
COP Tj = +7°C
6.45
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.70
6.25
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.00 kW
11.00 kW
COP Tj = Tbiv
2.50
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
11.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.48
1.90
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
5164 kWh
6313 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
14.00 kW
13.00 kW
Entrada EI
3.11 kW
4.48 kW
COP
4.50
2.90
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
57 dB(A)
57 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
191 %
143 %
Prated
11.70 kW
10.50 kW
SCOP
4.85
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.35 kW
9.29 kW
COP Tj = -7°C
3.05
2.26
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.10 kW
5.50 kW
COP Tj = +2°C
4.74
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.40 kW
4.30 kW
COP Tj = +7°C
6.50
4.87
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.80
6.30
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.70 kW
10.50 kW
COP Tj = Tbiv
2.55
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.70 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.55
1.91
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4986 kWh
5940 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.61 kW
4.07 kW
COP
4.60
2.95
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
56 dB(A)
56 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
187 %
143 %
Prated
11.00 kW
10.50 kW
SCOP
4.75
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.73 kW
9.29 kW
COP Tj = -7°C
3.06
2.26
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.92 kW
5.50 kW
COP Tj = +2°C
4.75
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.20 kW
4.30 kW
COP Tj = +7°C
6.00
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.80
6.30
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.00 kW
10.50 kW
COP Tj = Tbiv
2.60
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.00 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.60
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4783 kWh
5940 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
16.00 kW
14.00 kW
Entrada EI
3.64 kW
5.00 kW
COP
4.40
2.80
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
39 dB(A)
39 dB(A)
Potencia sonora de la unidad exterior
59 dB(A)
59 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
189 %
141 %
Prated
12.00 kW
11.00 kW
SCOP
4.80
3.60
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.40 kW
9.73 kW
COP Tj = -7°C
3.00
2.17
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.20 kW
5.92 kW
COP Tj = +2°C
4.70
3.54
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.30 kW
4.30 kW
COP Tj = +7°C
6.45
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.70
6.25
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.00 kW
11.00 kW
COP Tj = Tbiv
2.50
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
11.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.50
1.90
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
5164 kWh
6313 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
16.00 kW
14.00 kW
Entrada EI
3.64 kW
5.00 kW
COP
4.40
2.80
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
39 dB(A)
39 dB(A)
Potencia sonora de la unidad exterior
59 dB(A)
59 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
189 %
141 %
Prated
12.00 kW
11.00 kW
SCOP
4.80
3.60
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.40 kW
9.73 kW
COP Tj = -7°C
3.00
2.17
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.20 kW
5.92 kW
COP Tj = +2°C
4.70
3.54
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.30 kW
4.30 kW
COP Tj = +7°C
6.45
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.70
6.25
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.00 kW
11.00 kW
COP Tj = Tbiv
2.50
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
11.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.50
1.90
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
5164 kWh
6313 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
14.00 kW
13.00 kW
Entrada EI
3.11 kW
4.48 kW
COP
4.50
2.90
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
39 dB(A)
39 dB(A)
Potencia sonora de la unidad exterior
57 dB(A)
57 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
191 %
143 %
Prated
11.70 kW
10.50 kW
SCOP
4.85
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.35 kW
9.29 kW
COP Tj = -7°C
3.05
2.26
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.10 kW
5.50 kW
COP Tj = +2°C
4.74
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.40 kW
4.30 kW
COP Tj = +7°C
6.50
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.80
6.30
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.70 kW
10.50 kW
COP Tj = Tbiv
2.55
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.70 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.55
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4986 kWh
5940 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
14.00 kW
13.00 kW
Entrada EI
3.11 kW
4.48 kW
COP
4.50
2.90
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
39 dB(A)
39 dB(A)
Potencia sonora de la unidad exterior
57 dB(A)
57 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
191 %
143 %
Prated
11.70 kW
10.50 kW
SCOP
4.85
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.35 kW
9.29 kW
COP Tj = -7°C
3.05
2.26
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.10 kW
5.50 kW
COP Tj = +2°C
4.74
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.40 kW
4.30 kW
COP Tj = +7°C
6.50
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.80
6.30
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.70 kW
10.50 kW
COP Tj = Tbiv
2.55
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.70 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.55
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4986 kWh
5940 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.61 kW
4.07 kW
COP
4.60
2.95
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
39 dB(A)
39 dB(A)
Potencia sonora de la unidad exterior
56 dB(A)
56 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
187 %
143 %
Prated
11.00 kW
10.50 kW
SCOP
4.75
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.73 kW
9.29 kW
COP Tj = -7°C
3.06
2.26
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.92 kW
5.50 kW
COP Tj = +2°C
4.75
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.20 kW
4.30 kW
COP Tj = +7°C
6.00
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.80
6.30
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.00 kW
10.50 kW
COP Tj = Tbiv
2.60
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.00 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.60
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4783 kWh
5940 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.61 kW
4.07 kW
COP
4.60
2.95
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
39 dB(A)
39 dB(A)
Potencia sonora de la unidad exterior
56 dB(A)
56 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
187 %
143 %
Prated
11.00 kW
10.50 kW
SCOP
4.75
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.73 kW
9.29 kW
COP Tj = -7°C
3.06
2.26
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.92 kW
5.50 kW
COP Tj = +2°C
4.75
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.20 kW
4.30 kW
COP Tj = +7°C
6.00
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.80
6.30
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.00 kW
10.50 kW
COP Tj = Tbiv
2.60
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.00 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.60
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4783 kWh
5940 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
16.00 kW
14.00 kW
Entrada EI
3.64 kW
5.00 kW
COP
4.40
2.80
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
dB(A)
dB(A)
Potencia sonora de la unidad exterior
59 dB(A)
59 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
189 %
141 %
Prated
12.00 kW
11.00 kW
SCOP
4.80
3.60
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.40 kW
9.73 kW
COP Tj = -7°C
3.00
2.17
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.20 kW
5.92 kW
COP Tj = +2°C
4.70
3.54
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.30 kW
4.30 kW
COP Tj = +7°C
6.45
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.70
6.25
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.00 kW
11.00 kW
COP Tj = Tbiv
2.50
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
11.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.50
1.90
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
5164 kWh
6313 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
16.00 kW
14.00 kW
Entrada EI
3.64 kW
5.00 kW
COP
4.40
2.80
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
dB(A)
dB(A)
Potencia sonora de la unidad exterior
59 dB(A)
59 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
189 %
141 %
Prated
12.00 kW
11.00 kW
SCOP
4.80
3.60
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.40 kW
9.73 kW
COP Tj = -7°C
3.00
2.17
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.20 kW
5.92 kW
COP Tj = +2°C
4.70
3.54
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.30 kW
4.30 kW
COP Tj = +7°C
6.45
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.70
6.25
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.00 kW
11.00 kW
COP Tj = Tbiv
2.50
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
11.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.50
1.90
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
5164 kWh
6313 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
14.00 kW
13.00 kW
Entrada EI
3.11 kW
4.48 kW
COP
4.50
2.90
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
dB(A)
dB(A)
Potencia sonora de la unidad exterior
57 dB(A)
57 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
191 %
143 %
Prated
11.70 kW
10.50 kW
SCOP
4.85
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.35 kW
9.29 kW
COP Tj = -7°C
3.05
2.26
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.10 kW
5.50 kW
COP Tj = +2°C
4.74
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.40 kW
4.30 kW
COP Tj = +7°C
6.50
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.80
6.30
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.70 kW
10.50 kW
COP Tj = Tbiv
2.55
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.70 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.55
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4986 kWh
5940 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
14.00 kW
13.00 kW
Entrada EI
3.11 kW
4.48 kW
COP
4.50
2.90
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
dB(A)
dB(A)
Potencia sonora de la unidad exterior
57 dB(A)
57 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
191 %
143 %
Prated
11.70 kW
10.50 kW
SCOP
4.85
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.35 kW
9.29 kW
COP Tj = -7°C
3.05
2.26
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.10 kW
5.50 kW
COP Tj = +2°C
4.74
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.40 kW
4.30 kW
COP Tj = +7°C
6.50
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.80
6.30
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.70 kW
10.50 kW
COP Tj = Tbiv
2.55
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.70 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.55
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4986 kWh
5940 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.61 kW
4.07 kW
COP
4.60
2.95
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
dB(A)
dB(A)
Potencia sonora de la unidad exterior
56 dB(A)
56 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
187 %
143 %
Prated
11.00 kW
10.50 kW
SCOP
4.75
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.73 kW
9.29 kW
COP Tj = -7°C
3.06
2.26
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.92 kW
5.50 kW
COP Tj = +2°C
4.75
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.20 kW
4.30 kW
COP Tj = +7°C
6.00
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.80
6.30
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.00 kW
10.50 kW
COP Tj = Tbiv
2.60
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.00 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.60
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4783 kWh
5940 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.61 kW
4.07 kW
COP
4.60
2.95
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
dB(A)
dB(A)
Potencia sonora de la unidad exterior
56 dB(A)
56 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
187 %
143 %
Prated
11.00 kW
10.50 kW
SCOP
4.75
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.73 kW
9.29 kW
COP Tj = -7°C
3.06
2.26
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.92 kW
5.50 kW
COP Tj = +2°C
4.75
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.20 kW
4.30 kW
COP Tj = +7°C
6.00
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.80
6.30
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.00 kW
10.50 kW
COP Tj = Tbiv
2.60
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.00 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.60
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4783 kWh
5940 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
16.00 kW
14.00 kW
Entrada EI
3.64 kW
5.00 kW
COP
4.40
2.80
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
39 dB(A)
39 dB(A)
Potencia sonora de la unidad exterior
59 dB(A)
59 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
189 %
141 %
Prated
12.00 kW
11.00 kW
SCOP
4.80
3.60
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.40 kW
9.73 kW
COP Tj = -7°C
3.00
2.17
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.20 kW
5.92 kW
COP Tj = +2°C
4.70
3.54
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.30 kW
4.30 kW
COP Tj = +7°C
6.45
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.70
6.25
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.00 kW
11.00 kW
COP Tj = Tbiv
2.50
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
11.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.50
1.90
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
5164 kWh
6313 kWh
Agua caliente sanitaria
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
130 %
COP
3.00
Tiempo de calentamiento
1:05 h:min
Entrada de alimentación ( stand By )
47.0 W
Temperatura de referencia ACS
51.0 °C
Mezcla de agua a 40ºC
240 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
16.00 kW
14.00 kW
Entrada EI
3.64 kW
5.00 kW
COP
4.40
2.80
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
39 dB(A)
39 dB(A)
Potencia sonora de la unidad exterior
59 dB(A)
59 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
189 %
141 %
Prated
12.00 kW
11.00 kW
SCOP
4.80
3.60
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.40 kW
9.73 kW
COP Tj = -7°C
3.00
2.17
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.20 kW
5.92 kW
COP Tj = +2°C
4.70
3.54
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.30 kW
4.30 kW
COP Tj = +7°C
6.45
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.70
6.25
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.00 kW
11.00 kW
COP Tj = Tbiv
2.50
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
11.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.50
1.90
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
5164 kWh
6313 kWh
Agua caliente sanitaria
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
130 %
COP
3.00
Tiempo de calentamiento
1:05 h:min
Entrada de alimentación ( stand By )
47.0 W
Temperatura de referencia ACS
51.0 °C
Mezcla de agua a 40ºC
240 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
14.00 kW
13.00 kW
Entrada EI
3.11 kW
4.48 kW
COP
4.50
2.90
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
39 dB(A)
39 dB(A)
Potencia sonora de la unidad exterior
57 dB(A)
57 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
191 %
143 %
Prated
11.70 kW
10.50 kW
SCOP
4.85
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.35 kW
9.29 kW
COP Tj = -7°C
3.05
2.26
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.10 kW
5.50 kW
COP Tj = +2°C
4.74
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.40 kW
4.30 kW
COP Tj = +7°C
6.50
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.80
6.30
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.70 kW
10.50 kW
COP Tj = Tbiv
2.50
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.70 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.50
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4986 kWh
5940 kWh
Agua caliente sanitaria
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
130 %
COP
3.00
Tiempo de calentamiento
1:05 h:min
Entrada de alimentación ( stand By )
47.0 W
Temperatura de referencia ACS
51.0 °C
Mezcla de agua a 40ºC
240 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
14.00 kW
13.00 kW
Entrada EI
3.11 kW
4.48 kW
COP
4.50
2.90
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
39 dB(A)
39 dB(A)
Potencia sonora de la unidad exterior
57 dB(A)
57 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
191 %
143 %
Prated
11.70 kW
10.50 kW
SCOP
4.85
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.35 kW
9.29 kW
COP Tj = -7°C
3.05
2.26
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.10 kW
5.50 kW
COP Tj = +2°C
4.74
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.40 kW
4.30 kW
COP Tj = +7°C
6.50
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.80
6.30
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.70 kW
10.50 kW
COP Tj = Tbiv
2.55
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.70 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.55
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4986 kWh
5940 kWh
Agua caliente sanitaria
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
130 %
COP
3.00
Tiempo de calentamiento
1:05 h:min
Entrada de alimentación ( stand By )
47.0 W
Temperatura de referencia ACS
51.0 °C
Mezcla de agua a 40ºC
240 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.61 kW
4.07 kW
COP
4.60
2.95
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
39 dB(A)
39 dB(A)
Potencia sonora de la unidad exterior
56 dB(A)
56 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
187 %
143 %
Prated
11.00 kW
10.50 kW
SCOP
4.75
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.73 kW
9.29 kW
COP Tj = -7°C
3.06
2.26
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.92 kW
5.50 kW
COP Tj = +2°C
4.75
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.20 kW
4.30 kW
COP Tj = +7°C
6.00
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.80
6.30
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.00 kW
10.50 kW
COP Tj = Tbiv
2.60
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.00 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.60
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4783 kWh
5940 kWh
Agua caliente sanitaria
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
130 %
COP
3.00
Tiempo de calentamiento
1:05 h:min
Entrada de alimentación ( stand By )
47.0 W
Temperatura de referencia ACS
51.0 °C
Mezcla de agua a 40ºC
240 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.61 kW
4.07 kW
COP
4.60
2.95
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
39 dB(A)
39 dB(A)
Potencia sonora de la unidad exterior
56 dB(A)
56 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
187 %
143 %
Prated
11.00 kW
10.50 kW
SCOP
4.75
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.73 kW
9.29 kW
COP Tj = -7°C
3.06
2.26
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.92 kW
5.50 kW
COP Tj = +2°C
4.75
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.20 kW
4.30 kW
COP Tj = +7°C
6.00
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.80
6.30
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.00 kW
10.50 kW
COP Tj = Tbiv
2.60
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.00 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.60
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4783 kWh
5940 kWh
Agua caliente sanitaria
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
130 %
COP
3.00
Tiempo de calentamiento
1:05 h:min
Entrada de alimentación ( stand By )
47.0 W
Temperatura de referencia ACS
51.0 °C
Mezcla de agua a 40ºC
240 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
16.00 kW
14.00 kW
Entrada EI
3.64 kW
5.00 kW
COP
4.40
2.80
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
42 dB(A)
42 dB(A)
Potencia sonora de la unidad exterior
59 dB(A)
59 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
189 %
141 %
Prated
12.00 kW
11.00 kW
SCOP
4.80
3.60
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.40 kW
9.73 kW
COP Tj = -7°C
3.00
2.17
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.20 kW
5.92 kW
COP Tj = +2°C
4.70
3.54
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.30 kW
4.30 kW
COP Tj = +7°C
6.45
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.70
6.25
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.00 kW
11.00 kW
COP Tj = Tbiv
2.50
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
11.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.50
1.90
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
5164 kWh
6313 kWh
Agua caliente sanitaria
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
130 %
COP
3.00
Tiempo de calentamiento
1:05 h:min
Entrada de alimentación ( stand By )
47.0 W
Temperatura de referencia ACS
51.0 °C
Mezcla de agua a 40ºC
240 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
16.00 kW
14.00 kW
Entrada EI
3.64 kW
5.00 kW
COP
4.40
2.80
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
42 dB(A)
42 dB(A)
Potencia sonora de la unidad exterior
59 dB(A)
59 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
189 %
141 %
Prated
12.00 kW
11.00 kW
SCOP
4.80
3.60
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.40 kW
9.73 kW
COP Tj = -7°C
3.00
2.17
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.20 kW
5.92 kW
COP Tj = +2°C
4.70
3.54
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.30 kW
4.30 kW
COP Tj = +7°C
6.45
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.70
6.25
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.00 kW
11.00 kW
COP Tj = Tbiv
2.50
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
11.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.50
1.90
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
5164 kWh
6313 kWh
Agua caliente sanitaria
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
130 %
COP
3.00
Tiempo de calentamiento
1:05 h:min
Entrada de alimentación ( stand By )
47.0 W
Temperatura de referencia ACS
51.0 °C
Mezcla de agua a 40ºC
240 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
14.00 kW
13.00 kW
Entrada EI
3.11 kW
4.48 kW
COP
4.50
2.90
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
42 dB(A)
42 dB(A)
Potencia sonora de la unidad exterior
57 dB(A)
57 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
191 %
143 %
Prated
11.70 kW
10.50 kW
SCOP
4.85
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.35 kW
9.29 kW
COP Tj = -7°C
3.05
2.26
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.10 kW
5.50 kW
COP Tj = +2°C
4.74
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.40 kW
4.30 kW
COP Tj = +7°C
6.50
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.80
6.30
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.70 kW
10.50 kW
COP Tj = Tbiv
2.55
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.70 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.55
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4986 kWh
5940 kWh
Agua caliente sanitaria
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
130 %
COP
3.00
Tiempo de calentamiento
1:05 h:min
Entrada de alimentación ( stand By )
47.0 W
Temperatura de referencia ACS
51.0 °C
Mezcla de agua a 40ºC
240 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
14.00 kW
13.00 kW
Entrada EI
3.11 kW
4.48 kW
COP
4.50
2.90
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
42 dB(A)
42 dB(A)
Potencia sonora de la unidad exterior
57 dB(A)
57 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
191 %
143 %
Prated
11.70 kW
10.50 kW
SCOP
4.85
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.35 kW
9.29 kW
COP Tj = -7°C
3.05
2.26
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.10 kW
5.50 kW
COP Tj = +2°C
4.74
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.40 kW
4.30 kW
COP Tj = +7°C
6.50
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.80
6.30
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.70 kW
10.50 kW
COP Tj = Tbiv
2.55
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.70 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.55
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4986 kWh
5940 kWh
Agua caliente sanitaria
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
130 %
COP
3.00
Tiempo de calentamiento
1:05 h:min
Entrada de alimentación ( stand By )
47.0 W
Temperatura de referencia ACS
51.0 °C
Mezcla de agua a 40ºC
240 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.61 kW
4.07 kW
COP
4.60
2.95
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
42 dB(A)
42 dB(A)
Potencia sonora de la unidad exterior
56 dB(A)
56 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
187 %
143 %
Prated
11.00 kW
10.50 kW
SCOP
4.75
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.73 kW
9.29 kW
COP Tj = -7°C
3.06
2.26
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.92 kW
5.50 kW
COP Tj = +2°C
4.75
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.20 kW
4.30 kW
COP Tj = +7°C
6.00
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.80
6.30
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.00 kW
10.50 kW
COP Tj = Tbiv
2.60
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.00 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.60
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4783 kWh
5940 kWh
Agua caliente sanitaria
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
130 %
COP
3.00
Tiempo de calentamiento
1:05 h:min
Entrada de alimentación ( stand By )
47.0 W
Temperatura de referencia ACS
51.0 °C
Mezcla de agua a 40ºC
240 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.61 kW
4.07 kW
COP
4.60
2.95
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
42 dB(A)
42 dB(A)
Potencia sonora de la unidad exterior
56 dB(A)
56 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
187 %
143 %
Prated
11.00 kW
10.50 kW
SCOP
4.75
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.73 kW
9.29 kW
COP Tj = -7°C
3.06
2.26
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.92 kW
5.50 kW
COP Tj = +2°C
4.75
3.60
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.20 kW
4.30 kW
COP Tj = +7°C
6.00
4.89
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.00 kW
5.00 kW
COP Tj = 12°C
7.80
6.30
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.00 kW
10.50 kW
COP Tj = Tbiv
2.60
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.00 kW
10.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.60
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
30 W
30 W
PSB
10 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4783 kWh
5940 kWh
Agua caliente sanitaria
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
130 %
COP
3.00
Tiempo de calentamiento
1:05 h:min
Entrada de alimentación ( stand By )
47.0 W
Temperatura de referencia ACS
51.0 °C
Mezcla de agua a 40ºC
240 l