2,000 kg
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
22.66 kW
18.80 kW
Entrada EI
5.02 kW
6.19 kW
COP
4.51
3.04
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
5.36 kW
5.21 kW
Cooling capacity
15.51
21.02
EER
2.90
4.03
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
15.51 kW
21.02 kW
SEER
5.47
8.92
Pdc Tj = 35°C
15.51 kW
21.02 kW
EER Tj = 35°C
2.90
4.03
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
11.33 kW
15.58 kW
EER Tj = 30°C
4.21
6.59
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
7.37 kW
10.01 kW
EER Tj = 25°C
5.90
10.33
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
3.37 kW
4.81 kW
EER Tj = 20°C
9.16
15.58
Cdc Tj = 20 °C
0.900
0.900
Poff
9 W
9 W
PTO
15 W
15 W
PSB
9 W
9 W
PCK
0 W
0 W
Consumo annual de enertía QCE
1701 kWh
1413 kWh
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
55 dB(A)
55 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
203 %
156 %
Prated
15.96 kW
16.31 kW
SCOP
5.15
3.98
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
14.12 kW
14.43 kW
COP Tj = -7°C
3.00
2.33
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
8.69 kW
8.99 kW
COP Tj = +2°C
5.08
3.85
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
6.00 kW
6.19 kW
COP Tj = +7°C
6.95
5.65
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
6.91 kW
6.52 kW
COP Tj = 12°C
8.76
6.38
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
14.12 kW
14.43 kW
COP Tj = Tbiv
3.00
2.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.51 kW
13.38 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.78
2.10
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
9 W
9 W
PTO
15 W
15 W
PSB
9 W
9 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
2.45 kW
2.94 kW
Consumo annual de energia QHE
6461 kWh
8534 kWh