2,000 kg
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
13.16 kW
12.93 kW
Entrada EI
2.72 kW
3.88 kW
COP
4.84
3.33
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
3.58 kW
2.23 kW
Cooling capacity
10.18
9.98
EER
2.82
4.48
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
10.00 kW
10.00 kW
SEER
5.03
6.83
Pdc Tj = 35°C
10.12 kW
9.98 kW
EER Tj = 35°C
2.82
4.48
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
7.57 kW
7.32 kW
EER Tj = 30°C
4.09
5.80
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.81 kW
4.80 kW
EER Tj = 25°C
5.58
7.21
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
2.57 kW
3.67 kW
EER Tj = 20°C
6.69
8.80
Cdc Tj = 20 °C
0.980
0.980
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
8 W
8 W
Consumo annual de enertía QCE
1226 kWh
911 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
41 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
294 %
199 %
Prated
12.40 kW
12.50 kW
SCOP
7.48
5.06
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.60 kW
11.62 kW
COP Tj = +2°C
3.65
2.68
Cdh Tj = +2 °C
0.998
0.998
Pdh Tj = +7°C
7.47 kW
7.81 kW
COP Tj = +7°C
6.45
4.33
Cdh Tj = +7 °C
0.993
0.996
Pdh Tj = 12°C
3.71 kW
3.54 kW
COP Tj = 12°C
9.54
6.41
Cdh Tj = +12 °C
0.979
0.986
Pdh Tj = Tbiv
11.60 kW
11.62 kW
COP Tj = Tbiv
3.65
2.68
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.60 kW
11.62 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.65
2.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.998
0.998
WTOL
75 °C
75 °C
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
8 W
8 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2228 kWh
3314 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
41 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
204 %
151 %
Prated
12.00 kW
12.00 kW
SCOP
5.18
3.84
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.94 kW
7.02 kW
COP Tj = -7°C
4.19
3.14
Cdh Tj = -7 °C
0.995
0.996
Pdh Tj = +2°C
4.20 kW
4.25 kW
COP Tj = +2°C
6.68
4.78
Cdh Tj = +2 °C
0.987
0.991
Pdh Tj = +7°C
3.30 kW
3.03 kW
COP Tj = +7°C
8.08
5.83
Cdh Tj = +7 °C
0.980
0.985
Pdh Tj = 12°C
3.74 kW
3.63 kW
COP Tj = 12°C
9.98
7.79
Cdh Tj = +12 °C
0.979
0.983
Pdh Tj = Tbiv
10.05 kW
9.99 kW
COP Tj = Tbiv
2.86
2.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.64 kW
8.13 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.36
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.998
0.998
WTOL
75 °C
75 °C
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
8 W
8 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
3.36 kW
3.87 kW
Consumo annual de energia QHE
5711 kWh
7698 kWh
Pdh Tj = -15°C (if TOL<-20°C)
10.05
9.99
COP Tj = -15°C (if TOL<-20°C)
2.86
2.20
Cdh Tj = -15 °C
0.998
0.998
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
41 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
237 %
168 %
Prated
10.50 kW
10.50 kW
SCOP
6.01
4.28
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.70 kW
8.73 kW
COP Tj = -7°C
3.66
2.62
Cdh Tj = -7 °C
0.997
0.998
Pdh Tj = +2°C
5.24 kW
5.30 kW
COP Tj = +2°C
5.92
4.22
Cdh Tj = +2 °C
0.991
0.994
Pdh Tj = +7°C
3.51 kW
3.47 kW
COP Tj = +7°C
7.69
5.42
Cdh Tj = +7 °C
0.983
0.988
Pdh Tj = 12°C
3.77 kW
3.43 kW
COP Tj = 12°C
9.89
7.20
Cdh Tj = +12 °C
0.979
0.983
Pdh Tj = Tbiv
9.66 kW
9.52 kW
COP Tj = Tbiv
3.19
2.28
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.66 kW
9.52 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.19
2.28
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
75 °C
75 °C
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
8 W
8 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3614 kWh
5068 kWh