2,500 kg
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
18.38 kW
18.52 kW
Entrada EI
3.82 kW
5.44 kW
COP
4.81
3.40
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
8.12 kW
4.62 kW
Cooling capacity
18.56
18.49
EER
2.29
4.00
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
14.50 kW
14.50 kW
SEER
5.07
6.95
Pdc Tj = 35°C
14.28 kW
13.84 kW
EER Tj = 35°C
2.89
4.57
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
10.61 kW
10.69 kW
EER Tj = 30°C
4.19
5.86
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
6.82 kW
6.50 kW
EER Tj = 25°C
5.62
7.53
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.66 kW
6.35 kW
EER Tj = 20°C
6.57
8.62
Cdc Tj = 20 °C
0.990
0.990
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
8 W
8 W
Consumo annual de enertía QCE
1750 kWh
1284 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
38 dB(A)
40 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
301 %
210 %
Prated
15.50 kW
15.90 kW
SCOP
7.62
5.33
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
15.19 kW
15.24 kW
COP Tj = +2°C
3.78
2.79
Cdh Tj = +2 °C
0.999
0.999
Pdh Tj = +7°C
9.50 kW
9.66 kW
COP Tj = +7°C
6.78
4.49
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
5.90 kW
5.39 kW
COP Tj = 12°C
9.43
6.88
Cdh Tj = +12 °C
0.990
0.992
Pdh Tj = Tbiv
15.19 kW
15.24 kW
COP Tj = Tbiv
3.78
2.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
15.19 kW
15.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.78
2.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.999
0.999
WTOL
75 °C
75 °C
Poff
6 W
6 W
PTO
6 W
6 W
PSB
6 W
6 W
PCK
6 W
6 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2727 kWh
3997 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
38 dB(A)
40 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
214 %
158 %
Prated
16.00 kW
16.00 kW
SCOP
5.43
4.03
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
9.02 kW
9.04 kW
COP Tj = -7°C
4.34
3.23
Cdh Tj = -7 °C
0.997
0.998
Pdh Tj = +2°C
5.90 kW
5.83 kW
COP Tj = +2°C
7.02
5.01
Cdh Tj = +2 °C
0.993
0.995
Pdh Tj = +7°C
5.37 kW
5.01 kW
COP Tj = +7°C
8.49
6.66
Cdh Tj = +7 °C
0.991
0.992
Pdh Tj = 12°C
5.99 kW
5.63 kW
COP Tj = 12°C
9.88
7.92
Cdh Tj = +12 °C
0.990
0.992
Pdh Tj = Tbiv
13.04 kW
13.06 kW
COP Tj = Tbiv
2.93
2.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.84 kW
13.14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.30
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.999
0.999
WTOL
75 °C
75 °C
Poff
6 W
6 W
PTO
6 W
6 W
PSB
6 W
6 W
PCK
6 W
6 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
2.16 kW
2.94 kW
Consumo annual de energia QHE
7270 kWh
9782 kWh
Pdh Tj = -15°C (if TOL<-20°C)
13.04
13.06
COP Tj = -15°C (if TOL<-20°C)
2.93
2.27
Cdh Tj = -15 °C
0.999
0.999
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
38 dB(A)
40 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
246 %
175 %
Prated
14.50 kW
14.50 kW
SCOP
6.22
4.45
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.63 kW
12.11 kW
COP Tj = -7°C
3.73
2.66
Cdh Tj = -7 °C
0.998
0.999
Pdh Tj = +2°C
7.13 kW
7.32 kW
COP Tj = +2°C
6.26
4.37
Cdh Tj = +2 °C
0.995
0.996
Pdh Tj = +7°C
5.42 kW
4.95 kW
COP Tj = +7°C
7.93
5.73
Cdh Tj = +7 °C
0.991
0.993
Pdh Tj = 12°C
5.92 kW
5.51 kW
COP Tj = 12°C
9.25
7.72
Cdh Tj = +12 °C
0.991
0.992
Pdh Tj = Tbiv
13.98 kW
13.82 kW
COP Tj = Tbiv
3.15
2.31
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.98 kW
13.82 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.15
2.31
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.991
0.999
WTOL
75 °C
75 °C
Poff
6 W
6 W
PTO
6 W
6 W
PSB
6 W
6 W
PCK
6 W
6 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4819 kWh
6733 kWh