1,650 kg
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
8.40 kW
7.50 kW
Entrada EI
1.63 kW
2.36 kW
COP
5.15
3.18
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
2.22 kW
1.64 kW
Cooling capacity
7.45
8.30
EER
3.35
5.05
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.40 kW
8.40 kW
SEER
5.78
8.91
Pdc Tj = 35°C
7.38 kW
8.37 kW
EER Tj = 35°C
3.39
5.09
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
5.72 kW
6.47 kW
EER Tj = 30°C
4.71
7.02
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
3.62 kW
4.31 kW
EER Tj = 25°C
6.65
10.67
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
1.64 kW
1.80 kW
EER Tj = 20°C
8.55
13.61
Cdc Tj = 20 °C
0.900
0.900
Poff
14 W
14 W
PTO
10 W
10 W
PSB
14 W
14 W
PCK
0 W
0 W
Consumo annual de enertía QCE
768 kWh
566 kWh
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
39 dB(A)
39 dB(A)
Potencia sonora de la unidad exterior
59 dB(A)
59 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
205 %
131 %
Prated
8.10 kW
6.60 kW
SCOP
5.16
3.31
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.18 kW
5.84 kW
COP Tj = -7°C
3.35
2.16
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.65 kW
3.75 kW
COP Tj = +2°C
5.09
3.30
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.90 kW
2.42 kW
COP Tj = +7°C
6.82
4.34
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.63 kW
1.39 kW
COP Tj = 12°C
8.35
5.33
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.18 kW
5.84 kW
COP Tj = Tbiv
3.35
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.44 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
1.66 kW
1.70 kW
Consumo annual de energia QHE
3218 kWh
4056 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
10.00 kW
9.50 kW
Entrada EI
2.02 kW
3.06 kW
COP
4.95
3.10
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
2.52 kW
2.18 kW
Cooling capacity
8.20
9.90
EER
3.25
4.55
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
8.70 kW
10.00 kW
SEER
5.93
8.73
Pdc Tj = 35°C
8.73 kW
10.01 kW
EER Tj = 35°C
3.21
4.64
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
6.68 kW
7.71 kW
EER Tj = 30°C
4.47
6.45
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
4.26 kW
5.03 kW
EER Tj = 25°C
7.02
10.36
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
1.94 kW
2.32 kW
EER Tj = 20°C
9.54
14.98
Cdc Tj = 20 °C
0.900
0.900
Poff
14 W
14 W
PTO
10 W
10 W
PSB
14 W
14 W
PCK
0 W
0 W
Consumo annual de enertía QCE
880 kWh
687 kWh
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
39 dB(A)
39 dB(A)
Potencia sonora de la unidad exterior
60 dB(A)
60 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
204 %
136 %
Prated
9.20 kW
7.70 kW
SCOP
5.13
3.43
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.10 kW
6.78 kW
COP Tj = -7°C
3.23
2.24
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.18 kW
4.28 kW
COP Tj = +2°C
5.01
3.42
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.32 kW
2.77 kW
COP Tj = +7°C
7.08
4.52
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.65 kW
1.58 kW
COP Tj = 12°C
8.58
5.68
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.10 kW
6.78 kW
COP Tj = Tbiv
3.23
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.40 kW
5.38 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.96
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
1.80 kW
2.32 kW
Consumo annual de energia QHE
3644 kWh
4539 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
8.40 kW
7.50 kW
Entrada EI
1.63 kW
2.36 kW
COP
5.15
3.18
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
2.22 kW
1.64 kW
Cooling capacity
7.45
8.30
EER
3.35
5.05
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.40 kW
8.40 kW
SEER
5.78
8.91
Pdc Tj = 35°C
7.38 kW
8.37 kW
EER Tj = 35°C
3.39
5.09
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
5.72 kW
6.47 kW
EER Tj = 30°C
4.71
7.02
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
3.62 kW
4.31 kW
EER Tj = 25°C
6.65
10.67
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
1.64 kW
1.80 kW
EER Tj = 20°C
8.55
13.61
Cdc Tj = 20 °C
0.900
0.900
Poff
14 W
14 W
PTO
10 W
10 W
PSB
14 W
14 W
PCK
0 W
0 W
Consumo annual de enertía QCE
768 kWh
566 kWh
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
39 dB(A)
39 dB(A)
Potencia sonora de la unidad exterior
59 dB(A)
59 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
205 %
131 %
Prated
8.10 kW
6.60 kW
SCOP
5.16
3.31
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.18 kW
5.84 kW
COP Tj = -7°C
3.35
2.16
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.65 kW
3.75 kW
COP Tj = +2°C
5.09
3.30
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.90 kW
2.42 kW
COP Tj = +7°C
6.82
4.34
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.63 kW
1.39 kW
COP Tj = 12°C
8.35
5.33
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.18 kW
5.84 kW
COP Tj = Tbiv
3.35
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.44 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
1.66 kW
1.70 kW
Consumo annual de energia QHE
3218 kWh
4056 kWh
Agua caliente sanitaria
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
114 %
COP
2.82
Tiempo de calentamiento
2:25 h:min
Entrada de alimentación ( stand By )
45.0 W
Temperatura de referencia ACS
50.0 °C
Mezcla de agua a 40ºC
215 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
10.00 kW
9.50 kW
Entrada EI
2.02 kW
3.06 kW
COP
4.95
3.10
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
2.52 kW
2.18 kW
Cooling capacity
8.20
9.90
EER
3.25
4.55
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
8.70 kW
10.00 kW
SEER
5.93
8.73
Pdc Tj = 35°C
8.73 kW
10.01 kW
EER Tj = 35°C
3.21
4.64
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
6.68 kW
7.71 kW
EER Tj = 30°C
4.47
6.45
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
4.26 kW
5.03 kW
EER Tj = 25°C
7.02
10.36
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
1.94 kW
2.32 kW
EER Tj = 20°C
9.54
14.98
Cdc Tj = 20 °C
0.900
0.900
Poff
14 W
14 W
PTO
10 W
10 W
PSB
14 W
14 W
PCK
0 W
0 W
Consumo annual de enertía QCE
880 kWh
687 kWh
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
39 dB(A)
39 dB(A)
Potencia sonora de la unidad exterior
60 dB(A)
60 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
204 %
136 %
Prated
9.20 kW
7.70 kW
SCOP
5.13
3.43
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.10 kW
6.78 kW
COP Tj = -7°C
3.23
2.24
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.18 kW
4.28 kW
COP Tj = +2°C
5.01
3.42
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.32 kW
2.77 kW
COP Tj = +7°C
7.08
4.52
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.65 kW
1.58 kW
COP Tj = 12°C
8.58
5.68
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.10 kW
6.78 kW
COP Tj = Tbiv
3.23
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.40 kW
5.38 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.96
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
24 W
24 W
PSB
14 W
14 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
1.80 kW
2.32 kW
Consumo annual de energia QHE
3644 kWh
4539 kWh
Agua caliente sanitaria
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
114 %
COP
2.85
Tiempo de calentamiento
2:15 h:min
Entrada de alimentación ( stand By )
47.0 W
Temperatura de referencia ACS
50.0 °C
Mezcla de agua a 40ºC
215 l