1,300 kg
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.55 kW
3.75 kW
COP
4.70
3.20
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
55 dB(A)
55 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
262 %
192 %
Prated
12.00 kW
12.00 kW
SCOP
6.65
4.87
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.67 kW
11.63 kW
COP Tj = +2°C
3.37
2.53
Cdh Tj = +2 °C
0.993
0.995
Pdh Tj = +7°C
7.76 kW
7.80 kW
COP Tj = +7°C
5.80
4.14
Cdh Tj = +7 °C
0.983
0.988
Pdh Tj = 12°C
4.28 kW
4.11 kW
COP Tj = 12°C
8.81
6.50
Cdh Tj = +12 °C
0.953
0.964
Pdh Tj = Tbiv
7.76 kW
7.80 kW
COP Tj = Tbiv
5.80
4.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.67 kW
11.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.37
2.53
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
75 °C
75 °C
Poff
11 W
11 W
PTO
23 W
23 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.35 kW
0.35 kW
Consumo annual de energia QHE
2411 kWh
3289 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
55 dB(A)
55 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
165 %
131 %
Prated
10.70 kW
10.70 kW
SCOP
4.20
3.36
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.86 kW
6.50 kW
COP Tj = -7°C
3.45
2.80
Cdh Tj = -7 °C
0.988
0.990
Pdh Tj = +2°C
4.09 kW
4.01 kW
COP Tj = +2°C
4.93
3.91
Cdh Tj = +2 °C
0.972
0.978
Pdh Tj = +7°C
3.59 kW
3.45 kW
COP Tj = +7°C
6.82
5.34
Cdh Tj = +7 °C
0.956
0.964
Pdh Tj = 12°C
4.26 kW
4.14 kW
COP Tj = 12°C
8.54
6.83
Cdh Tj = +12 °C
0.954
0.962
Pdh Tj = Tbiv
9.01 kW
8.84 kW
COP Tj = Tbiv
2.63
2.11
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.88 kW
9.04 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.04
1.70
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
75 °C
75 °C
Poff
11 W
11 W
PTO
23 W
23 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.80 kW
1.70 kW
Consumo annual de energia QHE
6278 kWh
7841 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.01
8.84
COP Tj = -15°C (if TOL<-20°C)
2.63
2.11
Cdh Tj = -15 °C
0.993
0.995
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
55 dB(A)
55 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
182 %
143 %
Prated
11.50 kW
11.00 kW
SCOP
4.63
3.66
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.22 kW
9.73 kW
COP Tj = -7°C
2.87
2.27
Cdh Tj = -7 °C
0.994
0.995
Pdh Tj = +2°C
6.28 kW
5.92 kW
COP Tj = +2°C
4.21
3.43
Cdh Tj = +2 °C
0.985
0.987
Pdh Tj = +7°C
4.13 kW
3.86 kW
COP Tj = +7°C
6.96
5.18
Cdh Tj = +7 °C
0.961
0.969
Pdh Tj = 12°C
4.27 kW
4.09 kW
COP Tj = 12°C
8.80
6.53
Cdh Tj = +12 °C
0.953
0.963
Pdh Tj = Tbiv
10.22 kW
9.73 kW
COP Tj = Tbiv
2.87
2.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.77 kW
9.35 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.75
2.11
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
75 °C
75 °C
Poff
11 W
11 W
PTO
23 W
23 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
1.70 kW
1.60 kW
Consumo annual de energia QHE
5128 kWh
6201 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
14.00 kW
14.00 kW
Entrada EI
3.11 kW
4.52 kW
COP
4.50
3.10
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
56 dB(A)
56 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
255 %
188 %
Prated
14.20 kW
14.00 kW
SCOP
6.46
4.79
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.33 kW
12.58 kW
COP Tj = +2°C
3.39
2.49
Cdh Tj = +2 °C
0.994
0.995
Pdh Tj = +7°C
9.13 kW
9.07 kW
COP Tj = +7°C
5.64
4.06
Cdh Tj = +7 °C
0.986
0.990
Pdh Tj = 12°C
4.29 kW
4.02 kW
COP Tj = 12°C
9.31
6.66
Cdh Tj = +12 °C
0.950
0.962
Pdh Tj = Tbiv
9.13 kW
9.07 kW
COP Tj = Tbiv
5.64
4.06
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.33 kW
12.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.39
2.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
75 °C
75 °C
Poff
11 W
11 W
PTO
23 W
23 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
1.90 kW
1.40 kW
Consumo annual de energia QHE
2937 kWh
3901 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
56 dB(A)
56 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
165 %
133 %
Prated
13.20 kW
12.80 kW
SCOP
4.21
3.42
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.89 kW
7.86 kW
COP Tj = -7°C
3.31
2.81
Cdh Tj = -7 °C
0.990
0.992
Pdh Tj = +2°C
5.09 kW
4.84 kW
COP Tj = +2°C
5.17
4.04
Cdh Tj = +2 °C
0.977
0.981
Pdh Tj = +7°C
3.67 kW
3.50 kW
COP Tj = +7°C
7.43
5.69
Cdh Tj = +7 °C
0.954
0.963
Pdh Tj = 12°C
4.26 kW
4.08 kW
COP Tj = 12°C
8.82
7.04
Cdh Tj = +12 °C
0.952
0.960
Pdh Tj = Tbiv
10.84 kW
10.52 kW
COP Tj = Tbiv
2.46
2.10
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.05 kW
8.91 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.17
1.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
75 °C
75 °C
Poff
11 W
11 W
PTO
23 W
23 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
3.10 kW
3.90 kW
Consumo annual de energia QHE
7737 kWh
9224 kWh
Pdh Tj = -15°C (if TOL<-20°C)
10.84
10.52
COP Tj = -15°C (if TOL<-20°C)
2.46
2.10
Cdh Tj = -15 °C
0.995
0.995
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
56 dB(A)
56 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
181 %
144 %
Prated
13.70 kW
13.00 kW
SCOP
4.62
3.70
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.21 kW
11.61 kW
COP Tj = -7°C
2.76
2.18
Cdh Tj = -7 °C
0.995
0.996
Pdh Tj = +2°C
7.35 kW
7.33 kW
COP Tj = +2°C
4.25
3.46
Cdh Tj = +2 °C
0.987
0.989
Pdh Tj = +7°C
4.78 kW
4.64 kW
COP Tj = +7°C
7.02
5.41
Cdh Tj = +7 °C
0.966
0.973
Pdh Tj = 12°C
4.27 kW
4.18 kW
COP Tj = 12°C
9.12
7.12
Cdh Tj = +12 °C
0.951
0.961
Pdh Tj = Tbiv
12.21 kW
11.61 kW
COP Tj = Tbiv
2.76
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.81 kW
9.09 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.75
2.05
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
75 °C
75 °C
Poff
11 W
11 W
PTO
23 W
23 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
3.90 kW
3.90 kW
Consumo annual de energia QHE
6122 kWh
7267 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
15.00 kW
15.00 kW
Entrada EI
3.45 kW
4.87 kW
COP
4.35
3.08
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
56 dB(A)
56 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
254 %
186 %
Prated
14.40 kW
14.50 kW
SCOP
6.43
4.74
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.64 kW
12.59 kW
COP Tj = +2°C
3.38
2.50
Cdh Tj = +2 °C
0.994
0.995
Pdh Tj = +7°C
9.28 kW
9.32 kW
COP Tj = +7°C
5.58
4.06
Cdh Tj = +7 °C
0.986
0.990
Pdh Tj = 12°C
4.26 kW
4.04 kW
COP Tj = 12°C
9.22
6.62
Cdh Tj = +12 °C
0.950
0.962
Pdh Tj = Tbiv
9.28 kW
9.32 kW
COP Tj = Tbiv
5.58
4.06
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.64 kW
12.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.38
2.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
75 °C
75 °C
Poff
11 W
11 W
PTO
23 W
23 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
1.80 kW
1.90 kW
Consumo annual de energia QHE
2992 kWh
4085 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
56 dB(A)
56 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
163 %
132 %
Prated
13.50 kW
13.20 kW
SCOP
4.15
3.38
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.49 kW
7.87 kW
COP Tj = -7°C
3.27
2.84
Cdh Tj = -7 °C
0.991
0.992
Pdh Tj = +2°C
5.04 kW
4.74 kW
COP Tj = +2°C
5.12
3.98
Cdh Tj = +2 °C
0.977
0.981
Pdh Tj = +7°C
3.62 kW
3.46 kW
COP Tj = +7°C
7.24
5.62
Cdh Tj = +7 °C
0.954
0.963
Pdh Tj = 12°C
4.27 kW
4.10 kW
COP Tj = 12°C
8.87
6.91
Cdh Tj = +12 °C
0.952
0.961
Pdh Tj = Tbiv
11.04 kW
10.90 kW
COP Tj = Tbiv
2.44
1.99
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.02 kW
9.14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.04
1.71
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
75 °C
75 °C
Poff
11 W
11 W
PTO
23 W
23 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
3.50 kW
4.10 kW
Consumo annual de energia QHE
8016 kWh
9616 kWh
Pdh Tj = -15°C (if TOL<-20°C)
11.04
10.90
COP Tj = -15°C (if TOL<-20°C)
2.44
1.99
Cdh Tj = -15 °C
0.995
0.996
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
56 dB(A)
56 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
180 %
143 %
Prated
13.80 kW
13.60 kW
SCOP
4.58
3.65
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.24 kW
12.03 kW
COP Tj = -7°C
2.77
2.18
Cdh Tj = -7 °C
0.995
0.996
Pdh Tj = +2°C
7.42 kW
7.41 kW
COP Tj = +2°C
4.19
3.45
Cdh Tj = +2 °C
0.987
0.989
Pdh Tj = +7°C
5.02 kW
4.77 kW
COP Tj = +7°C
6.99
5.23
Cdh Tj = +7 °C
0.968
0.975
Pdh Tj = 12°C
4.26 kW
4.14 kW
COP Tj = 12°C
9.01
6.69
Cdh Tj = +12 °C
0.951
0.963
Pdh Tj = Tbiv
12.24 kW
12.03 kW
COP Tj = Tbiv
2.77
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.79 kW
9.45 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.72
2.13
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.994
0.995
WTOL
75 °C
75 °C
Poff
11 W
11 W
PTO
23 W
23 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
4.00 kW
4.20 kW
Consumo annual de energia QHE
6220 kWh
7692 kWh