2,500 kg
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
11.56 kW
17.41 kW
Entrada EI
2.14 kW
5.51 kW
COP
5.41
3.16
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
51 dB(A)
51 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
261 %
189 %
Prated
17.50 kW
17.95 kW
SCOP
6.60
4.81
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
17.50 kW
17.95 kW
COP Tj = +2°C
3.72
2.57
Cdh Tj = +2 °C
0.988
0.992
Pdh Tj = +7°C
11.19 kW
11.56 kW
COP Tj = +7°C
6.17
4.12
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
9.32 kW
8.95 kW
COP Tj = 12°C
8.35
6.43
Cdh Tj = +12 °C
0.949
0.975
Pdh Tj = Tbiv
17.50 kW
17.95 kW
COP Tj = Tbiv
3.72
2.57
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
17.50 kW
17.95 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.57
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.987
0.991
WTOL
70 °C
70 °C
Poff
31 W
31 W
PTO
55 W
55 W
PSB
56 W
56 W
PCK
55 W
55 W
Calentador suplementario: tipo de energía de entrada
n/a
n/a
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3542 kWh
4985 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
51 dB(A)
51 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
186 %
141 %
Prated
14.10 kW
14.48 kW
SCOP
4.72
3.59
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
9.01 kW
8.85 kW
COP Tj = -7°C
4.07
2.93
Cdh Tj = -7 °C
0.975
0.982
Pdh Tj = +2°C
7.19 kW
6.82 kW
COP Tj = +2°C
5.72
4.40
Cdh Tj = +2 °C
0.933
0.980
Pdh Tj = +7°C
8.11 kW
7.86 kW
COP Tj = +7°C
7.01
5.73
Cdh Tj = +7 °C
0.951
0.972
Pdh Tj = 12°C
9.36 kW
9.20 kW
COP Tj = 12°C
8.44
7.44
Cdh Tj = +12 °C
0.938
0.960
Pdh Tj = Tbiv
14.11 kW
14.48 kW
COP Tj = Tbiv
2.20
1.53
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14.11 kW
14.48 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.20
1.53
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.991
0.994
WTOL
70 °C
70 °C
Poff
31 W
31 W
PTO
55 W
55 W
PSB
56 W
56 W
PCK
55 W
55 W
Calentador suplementario: tipo de energía de entrada
n/a
n/a
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
7371 kWh
9934 kWh
Pdh Tj = -15°C (if TOL<-20°C)
11.58
11.73
COP Tj = -15°C (if TOL<-20°C)
2.96
2.12
Cdh Tj = -15 °C
0.986
0.990
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
51 dB(A)
51 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
205 %
155 %
Prated
19.70 kW
19.80 kW
SCOP
5.20
3.96
Tbiv
-10 °C
-10 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
16.10 kW
17.15 kW
COP Tj = -7°C
2.98
2.31
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
9.82 kW
9.94 kW
COP Tj = +2°C
5.29
3.92
Cdh Tj = +2 °C
0.970
0.970
Pdh Tj = +7°C
8.04 kW
7.64 kW
COP Tj = +7°C
6.90
5.27
Cdh Tj = +7 °C
0.953
0.973
Pdh Tj = 12°C
9.28 kW
9.03 kW
COP Tj = 12°C
8.61
7.04
Cdh Tj = +12 °C
0.912
0.951
Pdh Tj = Tbiv
19.79 kW
19.68 kW
COP Tj = Tbiv
2.77
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
19.79 kW
19.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.77
1.98
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.992
WTOL
70 °C
70 °C
Poff
31 W
31 W
PTO
55 W
55 W
PSB
56 W
56 W
PCK
55 W
55 W
Calentador suplementario: tipo de energía de entrada
n/a
n/a
Calentador suplementario: PSUP
0.00 kW
0.12 kW
Consumo annual de energia QHE
7826 kWh
10330 kWh