1,780 kg
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
9.00 kW
9.00 kW
Entrada EI
1.72 kW
2.78 kW
COP
5.23
3.24
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
2.49 kW
1.71 kW
Cooling capacity
9.00
9.00
EER
3.61
5.26
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
250 %
173 %
Prated
9.00 kW
9.00 kW
SCOP
6.33
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.00 kW
9.00 kW
COP Tj = +2°C
3.85
2.67
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.80 kW
5.80 kW
COP Tj = +7°C
5.89
3.81
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
5.70 kW
5.30 kW
COP Tj = 12°C
7.55
5.54
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.85
2.67
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.85
2.67
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
1901 kWh
2735 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
175 %
125 %
Prated
9.00 kW
9.00 kW
SCOP
4.45
3.20
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.50 kW
5.50 kW
COP Tj = -7°C
3.94
2.66
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.30 kW
3.80 kW
COP Tj = +2°C
4.94
3.60
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
4.90 kW
4.90 kW
COP Tj = +7°C
6.27
4.80
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.80 kW
5.70 kW
COP Tj = 12°C
7.61
6.10
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
2.25
1.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.25
1.65
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4990 kWh
6939 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.30
7.30
COP Tj = -15°C (if TOL<-20°C)
3.00
2.21
Cdh Tj = -15 °C
0.990
0.990
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
197 %
140 %
Prated
9.00 kW
9.00 kW
SCOP
5.00
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.00 kW
8.00 kW
COP Tj = -7°C
3.52
2.53
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.90 kW
4.90 kW
COP Tj = +2°C
4.84
3.37
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
4.80 kW
4.70 kW
COP Tj = +7°C
6.15
4.53
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.80
5.90
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.19
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.19
2.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3721 kWh
5201 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
9.00 kW
9.00 kW
Entrada EI
1.72 kW
2.78 kW
COP
5.23
3.24
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
2.49 kW
1.71 kW
Cooling capacity
9.00
9.00
EER
3.61
5.26
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
250 %
173 %
Prated
9.00 kW
9.00 kW
SCOP
6.33
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.00 kW
9.00 kW
COP Tj = +2°C
3.85
2.67
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.80 kW
5.80 kW
COP Tj = +7°C
5.89
3.81
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
5.70 kW
5.30 kW
COP Tj = 12°C
7.55
5.54
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.85
2.67
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.85
2.67
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
1901 kWh
2735 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
175 %
125 %
Prated
9.00 kW
9.00 kW
SCOP
4.45
3.20
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.50 kW
5.50 kW
COP Tj = -7°C
3.94
2.66
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.30 kW
3.80 kW
COP Tj = +2°C
4.94
3.60
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
4.90 kW
4.90 kW
COP Tj = +7°C
6.27
4.80
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.80 kW
5.70 kW
COP Tj = 12°C
7.61
6.10
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
2.25
1.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.25
1.65
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4990 kWh
6939 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.30
7.30
COP Tj = -15°C (if TOL<-20°C)
3.00
2.21
Cdh Tj = -15 °C
0.990
0.990
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
197 %
140 %
Prated
9.00 kW
9.00 kW
SCOP
5.00
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.00 kW
8.00 kW
COP Tj = -7°C
3.52
2.53
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.90 kW
4.90 kW
COP Tj = +2°C
4.84
3.37
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
4.80 kW
4.70 kW
COP Tj = +7°C
6.15
4.53
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.80
5.90
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.19
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.19
2.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3721 kWh
5201 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
9.00 kW
9.00 kW
Entrada EI
1.72 kW
2.78 kW
COP
5.23
3.24
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
2.49 kW
1.71 kW
Cooling capacity
9.00
9.00
EER
3.61
5.26
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
250 %
173 %
Prated
9.00 kW
9.00 kW
SCOP
6.33
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.00 kW
9.00 kW
COP Tj = +2°C
3.85
2.67
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.80 kW
5.80 kW
COP Tj = +7°C
5.89
3.81
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
5.70 kW
5.30 kW
COP Tj = 12°C
7.55
5.54
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.85
2.67
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.85
2.67
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
1901 kWh
2735 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
175 %
125 %
Prated
9.00 kW
9.00 kW
SCOP
4.45
3.20
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.50 kW
5.50 kW
COP Tj = -7°C
3.94
2.66
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.30 kW
3.80 kW
COP Tj = +2°C
4.94
3.60
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
4.90 kW
4.90 kW
COP Tj = +7°C
6.27
4.80
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.80 kW
5.70 kW
COP Tj = 12°C
7.61
6.10
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
2.25
1.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.25
1.65
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4990 kWh
6939 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.30
7.30
COP Tj = -15°C (if TOL<-20°C)
3.00
2.21
Cdh Tj = -15 °C
0.990
0.990
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
197 %
140 %
Prated
9.00 kW
9.00 kW
SCOP
5.00
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.00 kW
8.00 kW
COP Tj = -7°C
3.52
2.53
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.90 kW
4.90 kW
COP Tj = +2°C
4.84
3.37
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
4.80 kW
4.70 kW
COP Tj = +7°C
6.15
4.53
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.80
5.90
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.19
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.19
2.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3721 kWh
5201 kWh
Agua caliente sanitaria
Clima cálido
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
132 %
COP
3.30
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
43.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima frío
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
88 %
COP
2.20
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
66.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
123 %
COP
3.00
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
44.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
9.00 kW
9.00 kW
Entrada EI
1.72 kW
2.78 kW
COP
5.23
3.24
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
2.49 kW
1.71 kW
Cooling capacity
9.00
9.00
EER
3.61
5.26
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
250 %
173 %
Prated
9.00 kW
9.00 kW
SCOP
6.33
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.00 kW
9.00 kW
COP Tj = +2°C
3.85
2.67
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.80 kW
5.80 kW
COP Tj = +7°C
5.89
3.81
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
5.70 kW
5.30 kW
COP Tj = 12°C
7.55
5.54
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.85
2.67
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.85
2.67
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
1901 kWh
2735 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
175 %
125 %
Prated
9.00 kW
9.00 kW
SCOP
4.45
3.20
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.50 kW
5.50 kW
COP Tj = -7°C
3.94
2.66
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.30 kW
3.80 kW
COP Tj = +2°C
4.94
3.60
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
4.90 kW
4.90 kW
COP Tj = +7°C
6.27
4.80
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.80 kW
5.70 kW
COP Tj = 12°C
7.61
6.10
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
2.25
1.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.25
1.65
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4990 kWh
6939 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.30
7.30
COP Tj = -15°C (if TOL<-20°C)
3.00
2.21
Cdh Tj = -15 °C
0.990
0.990
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
197 %
140 %
Prated
9.00 kW
9.00 kW
SCOP
5.00
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.00 kW
8.00 kW
COP Tj = -7°C
3.52
2.53
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.90 kW
4.90 kW
COP Tj = +2°C
4.84
3.37
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
4.80 kW
4.70 kW
COP Tj = +7°C
6.15
4.53
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.80
5.90
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.19
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.19
2.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3721 kWh
5201 kWh
Agua caliente sanitaria
Clima cálido
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
132 %
COP
3.30
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
43.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima frío
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
88 %
COP
2.20
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
66.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
123 %
COP
3.00
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
44.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
9.00 kW
9.00 kW
Entrada EI
1.72 kW
2.78 kW
COP
5.23
3.24
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
2.49 kW
1.71 kW
Cooling capacity
9.00
9.00
EER
3.61
5.26
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
250 %
173 %
Prated
9.00 kW
9.00 kW
SCOP
6.33
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.00 kW
9.00 kW
COP Tj = +2°C
3.85
2.67
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.80 kW
5.80 kW
COP Tj = +7°C
5.89
3.81
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
5.70 kW
5.30 kW
COP Tj = 12°C
7.55
5.54
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.85
2.67
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.85
2.67
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
1901 kWh
2735 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
175 %
125 %
Prated
9.00 kW
9.00 kW
SCOP
4.45
3.20
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.50 kW
5.50 kW
COP Tj = -7°C
3.94
2.66
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.30 kW
3.80 kW
COP Tj = +2°C
4.94
3.60
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
4.90 kW
4.90 kW
COP Tj = +7°C
6.27
4.80
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.80 kW
5.70 kW
COP Tj = 12°C
7.61
6.10
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
2.25
1.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.25
1.65
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4990 kWh
6939 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.30
7.30
COP Tj = -15°C (if TOL<-20°C)
3.00
2.21
Cdh Tj = -15 °C
0.990
0.990
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
197 %
140 %
Prated
9.00 kW
9.00 kW
SCOP
5.00
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.00 kW
8.00 kW
COP Tj = -7°C
3.52
2.53
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.90 kW
4.90 kW
COP Tj = +2°C
4.84
3.37
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
4.80 kW
4.70 kW
COP Tj = +7°C
6.15
4.53
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.80
5.90
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.19
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.19
2.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3721 kWh
5201 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.37 kW
3.71 kW
COP
5.06
3.23
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
4.21 kW
2.80 kW
Cooling capacity
12.00
12.00
EER
2.85
4.29
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
245 %
173 %
Prated
12.00 kW
12.00 kW
SCOP
6.20
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.00 kW
12.00 kW
COP Tj = +2°C
3.53
2.51
Cdh Tj = +2 °C
0.990
1.000
Pdh Tj = +7°C
7.70 kW
7.70 kW
COP Tj = +7°C
5.62
3.94
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.54
5.36
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
3.53
2.51
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.53
2.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2586 kWh
3647 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
172 %
127 %
Prated
12.00 kW
12.00 kW
SCOP
4.38
3.25
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.30 kW
7.30 kW
COP Tj = -7°C
3.72
2.69
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.40 kW
5.50 kW
COP Tj = +2°C
4.95
3.70
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
5.30 kW
4.40 kW
COP Tj = +7°C
6.21
4.86
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.60 kW
5.70 kW
COP Tj = 12°C
7.54
5.95
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
2.13
1.56
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.13
1.56
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
6758 kWh
9111 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.80
9.80
COP Tj = -15°C (if TOL<-20°C)
2.98
2.19
Cdh Tj = -15 °C
0.990
1.000
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
186 %
143 %
Prated
12.00 kW
12.00 kW
SCOP
4.73
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.60 kW
10.60 kW
COP Tj = -7°C
2.79
2.22
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
6.50 kW
6.50 kW
COP Tj = +2°C
4.65
3.65
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.30 kW
4.90 kW
COP Tj = +7°C
6.25
4.57
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
6.10 kW
5.70 kW
COP Tj = 12°C
7.78
5.84
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
2.91
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
5244 kWh
6792 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.37 kW
3.71 kW
COP
5.06
3.23
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
4.21 kW
2.80 kW
Cooling capacity
12.00
12.00
EER
2.85
4.29
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
245 %
173 %
Prated
12.00 kW
12.00 kW
SCOP
6.20
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.00 kW
12.00 kW
COP Tj = +2°C
3.53
2.51
Cdh Tj = +2 °C
0.990
1.000
Pdh Tj = +7°C
7.70 kW
7.70 kW
COP Tj = +7°C
5.62
3.94
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.54
5.36
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
3.53
2.51
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.53
2.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2586 kWh
3647 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
172 %
127 %
Prated
12.00 kW
12.00 kW
SCOP
4.38
3.25
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.30 kW
7.30 kW
COP Tj = -7°C
3.72
2.69
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.40 kW
5.50 kW
COP Tj = +2°C
4.95
3.70
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
5.30 kW
4.40 kW
COP Tj = +7°C
6.21
4.86
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.60 kW
5.70 kW
COP Tj = 12°C
7.54
5.95
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
2.13
1.56
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.13
1.56
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
6758 kWh
9111 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.80
9.80
COP Tj = -15°C (if TOL<-20°C)
2.98
2.19
Cdh Tj = -15 °C
0.990
1.000
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
186 %
143 %
Prated
12.00 kW
12.00 kW
SCOP
4.73
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.60 kW
10.60 kW
COP Tj = -7°C
2.79
2.22
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
6.50 kW
6.50 kW
COP Tj = +2°C
4.65
3.65
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.30 kW
4.90 kW
COP Tj = +7°C
6.25
4.57
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
6.10 kW
5.70 kW
COP Tj = 12°C
7.78
5.84
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
2.91
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
5244 kWh
6792 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.37 kW
3.71 kW
COP
5.06
3.23
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
4.21 kW
2.80 kW
Cooling capacity
12.00
12.00
EER
2.85
4.29
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
245 %
173 %
Prated
12.00 kW
12.00 kW
SCOP
6.20
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.00 kW
12.00 kW
COP Tj = +2°C
3.53
2.51
Cdh Tj = +2 °C
0.990
1.000
Pdh Tj = +7°C
7.70 kW
7.70 kW
COP Tj = +7°C
5.62
3.94
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.54
5.36
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
3.53
2.51
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.53
2.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2586 kWh
3647 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
172 %
127 %
Prated
12.00 kW
12.00 kW
SCOP
4.38
3.25
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.30 kW
7.30 kW
COP Tj = -7°C
3.72
2.69
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.40 kW
5.50 kW
COP Tj = +2°C
4.95
3.70
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
5.30 kW
4.40 kW
COP Tj = +7°C
6.21
4.86
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.60 kW
5.70 kW
COP Tj = 12°C
7.54
5.95
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
2.13
1.56
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.13
1.56
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
6758 kWh
9111 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.80
9.80
COP Tj = -15°C (if TOL<-20°C)
2.98
2.19
Cdh Tj = -15 °C
0.990
1.000
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
186 %
143 %
Prated
12.00 kW
12.00 kW
SCOP
4.73
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.60 kW
10.60 kW
COP Tj = -7°C
2.79
2.22
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
6.50 kW
6.50 kW
COP Tj = +2°C
4.65
3.65
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.30 kW
4.90 kW
COP Tj = +7°C
6.25
4.57
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
6.10 kW
5.70 kW
COP Tj = 12°C
7.78
5.84
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
2.91
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
5244 kWh
6792 kWh
Agua caliente sanitaria
Clima cálido
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
132 %
COP
3.30
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
43.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima frío
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
88 %
COP
2.20
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
66.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
123 %
COP
3.00
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
44.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.37 kW
3.71 kW
COP
5.06
3.23
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
4.21 kW
2.80 kW
Cooling capacity
12.00
12.00
EER
2.85
4.29
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
245 %
173 %
Prated
12.00 kW
12.00 kW
SCOP
6.20
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.00 kW
12.00 kW
COP Tj = +2°C
3.53
2.51
Cdh Tj = +2 °C
0.990
1.000
Pdh Tj = +7°C
7.70 kW
7.70 kW
COP Tj = +7°C
5.62
3.94
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.54
5.36
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
3.53
2.51
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.53
2.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2586 kWh
3647 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
172 %
127 %
Prated
12.00 kW
12.00 kW
SCOP
4.38
3.25
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.30 kW
7.30 kW
COP Tj = -7°C
3.72
2.69
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.40 kW
5.50 kW
COP Tj = +2°C
4.95
3.70
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
5.30 kW
4.40 kW
COP Tj = +7°C
6.21
4.86
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.60 kW
5.70 kW
COP Tj = 12°C
7.54
5.95
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
2.13
1.56
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.13
1.56
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
6758 kWh
9111 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.80
9.80
COP Tj = -15°C (if TOL<-20°C)
2.98
2.19
Cdh Tj = -15 °C
0.990
1.000
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
186 %
143 %
Prated
12.00 kW
12.00 kW
SCOP
4.73
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.60 kW
10.60 kW
COP Tj = -7°C
2.79
2.22
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
6.50 kW
6.50 kW
COP Tj = +2°C
4.65
3.65
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.30 kW
4.90 kW
COP Tj = +7°C
6.25
4.57
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
6.10 kW
5.70 kW
COP Tj = 12°C
7.78
5.84
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
2.91
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
5244 kWh
6792 kWh
Agua caliente sanitaria
Clima cálido
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
132 %
COP
3.30
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
43.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima frío
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
88 %
COP
2.20
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
66.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
123 %
COP
3.00
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
44.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.37 kW
3.71 kW
COP
5.06
3.23
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
4.21 kW
2.80 kW
Cooling capacity
12.00
12.00
EER
2.85
4.29
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
245 %
173 %
Prated
12.00 kW
12.00 kW
SCOP
6.20
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.00 kW
12.00 kW
COP Tj = +2°C
3.53
2.51
Cdh Tj = +2 °C
0.990
1.000
Pdh Tj = +7°C
7.70 kW
7.70 kW
COP Tj = +7°C
5.62
3.94
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.54
5.36
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
3.53
2.51
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.53
2.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2586 kWh
3647 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
172 %
127 %
Prated
12.00 kW
12.00 kW
SCOP
4.38
3.25
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.30 kW
7.30 kW
COP Tj = -7°C
3.72
2.69
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.40 kW
5.50 kW
COP Tj = +2°C
4.95
3.70
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
5.30 kW
4.40 kW
COP Tj = +7°C
6.21
4.86
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.60 kW
5.70 kW
COP Tj = 12°C
7.54
5.95
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
2.13
1.56
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.13
1.56
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
6758 kWh
9111 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.80
9.80
COP Tj = -15°C (if TOL<-20°C)
2.98
2.19
Cdh Tj = -15 °C
0.990
1.000
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
186 %
143 %
Prated
12.00 kW
12.00 kW
SCOP
4.73
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.60 kW
10.60 kW
COP Tj = -7°C
2.79
2.22
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
6.50 kW
6.50 kW
COP Tj = +2°C
4.65
3.65
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.30 kW
4.90 kW
COP Tj = +7°C
6.25
4.57
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
6.10 kW
5.70 kW
COP Tj = 12°C
7.78
5.84
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
2.91
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
5244 kWh
6792 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
9.00 kW
9.00 kW
Entrada EI
1.72 kW
2.78 kW
COP
5.23
3.24
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
2.49 kW
1.71 kW
Cooling capacity
9.00
9.00
EER
3.61
5.26
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
250 %
173 %
Prated
9.00 kW
9.00 kW
SCOP
6.33
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.00 kW
9.00 kW
COP Tj = +2°C
3.85
2.67
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.80 kW
5.80 kW
COP Tj = +7°C
5.89
3.81
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
5.70 kW
5.30 kW
COP Tj = 12°C
7.55
5.54
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.85
2.67
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.85
2.67
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
1901 kWh
2735 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
175 %
125 %
Prated
9.00 kW
9.00 kW
SCOP
4.45
3.20
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.50 kW
5.50 kW
COP Tj = -7°C
3.94
2.66
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.30 kW
3.80 kW
COP Tj = +2°C
4.94
3.60
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
4.90 kW
4.90 kW
COP Tj = +7°C
6.27
4.80
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.80 kW
5.70 kW
COP Tj = 12°C
7.61
6.10
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
2.25
1.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.25
1.65
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4990 kWh
6939 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.30
7.30
COP Tj = -15°C (if TOL<-20°C)
3.00
2.21
Cdh Tj = -15 °C
0.990
0.990
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
197 %
140 %
Prated
9.00 kW
9.00 kW
SCOP
5.00
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.00 kW
8.00 kW
COP Tj = -7°C
3.52
2.53
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.90 kW
4.90 kW
COP Tj = +2°C
4.84
3.37
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
4.80 kW
4.70 kW
COP Tj = +7°C
6.15
4.53
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.80
5.90
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.19
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.19
2.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3721 kWh
5201 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
9.00 kW
9.00 kW
Entrada EI
1.72 kW
2.78 kW
COP
5.23
3.24
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
2.49 kW
1.71 kW
Cooling capacity
9.00
9.00
EER
3.61
5.26
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
250 %
173 %
Prated
9.00 kW
9.00 kW
SCOP
6.33
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.00 kW
9.00 kW
COP Tj = +2°C
3.85
2.67
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.80 kW
5.80 kW
COP Tj = +7°C
5.89
3.81
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
5.70 kW
5.30 kW
COP Tj = 12°C
7.55
5.54
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.85
2.67
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.85
2.67
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
1901 kWh
2735 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
175 %
125 %
Prated
9.00 kW
9.00 kW
SCOP
4.45
3.20
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.50 kW
5.50 kW
COP Tj = -7°C
3.94
2.66
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.30 kW
3.80 kW
COP Tj = +2°C
4.94
3.60
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
4.90 kW
4.90 kW
COP Tj = +7°C
6.27
4.80
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.80 kW
5.70 kW
COP Tj = 12°C
7.61
6.10
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
2.25
1.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.25
1.65
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4990 kWh
6939 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.30
7.30
COP Tj = -15°C (if TOL<-20°C)
3.00
2.21
Cdh Tj = -15 °C
0.990
0.990
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
197 %
140 %
Prated
9.00 kW
9.00 kW
SCOP
5.00
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.00 kW
8.00 kW
COP Tj = -7°C
3.52
2.53
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.90 kW
4.90 kW
COP Tj = +2°C
4.84
3.37
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
4.80 kW
4.70 kW
COP Tj = +7°C
6.15
4.53
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.80
5.90
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.19
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.19
2.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3721 kWh
5201 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
9.00 kW
9.00 kW
Entrada EI
1.72 kW
2.78 kW
COP
5.23
3.24
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
2.49 kW
1.71 kW
Cooling capacity
9.00
9.00
EER
3.61
5.26
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
250 %
173 %
Prated
9.00 kW
9.00 kW
SCOP
6.33
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.00 kW
9.00 kW
COP Tj = +2°C
3.85
2.67
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.80 kW
5.80 kW
COP Tj = +7°C
5.89
3.81
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
5.70 kW
5.30 kW
COP Tj = 12°C
7.55
5.54
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.85
2.67
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.85
2.67
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
1901 kWh
2735 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
175 %
125 %
Prated
9.00 kW
9.00 kW
SCOP
4.45
3.20
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.50 kW
5.50 kW
COP Tj = -7°C
3.94
2.66
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.30 kW
3.80 kW
COP Tj = +2°C
4.94
3.60
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
4.90 kW
4.90 kW
COP Tj = +7°C
6.27
4.80
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.80 kW
5.70 kW
COP Tj = 12°C
7.61
6.10
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
2.25
1.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.25
1.65
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4990 kWh
6939 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.30
7.30
COP Tj = -15°C (if TOL<-20°C)
3.00
2.21
Cdh Tj = -15 °C
0.990
0.990
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
197 %
140 %
Prated
9.00 kW
9.00 kW
SCOP
5.00
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.00 kW
8.00 kW
COP Tj = -7°C
3.52
2.53
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.90 kW
4.90 kW
COP Tj = +2°C
4.84
3.37
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
4.80 kW
4.70 kW
COP Tj = +7°C
6.15
4.53
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.80
5.90
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.19
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.19
2.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3721 kWh
5201 kWh
Agua caliente sanitaria
Clima cálido
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
134 %
COP
3.35
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
43.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima frío
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
88 %
COP
2.20
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
66.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
123 %
COP
3.00
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
44.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
9.00 kW
9.00 kW
Entrada EI
1.72 kW
2.78 kW
COP
5.23
3.24
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
2.49 kW
1.71 kW
Cooling capacity
9.00
9.00
EER
3.61
5.26
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
250 %
173 %
Prated
9.00 kW
9.00 kW
SCOP
6.33
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.00 kW
9.00 kW
COP Tj = +2°C
3.85
2.67
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.80 kW
5.80 kW
COP Tj = +7°C
5.89
3.81
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
5.70 kW
5.30 kW
COP Tj = 12°C
7.55
5.54
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.85
2.67
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.85
2.67
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
1901 kWh
2735 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
175 %
125 %
Prated
9.00 kW
9.00 kW
SCOP
4.45
3.20
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.50 kW
5.50 kW
COP Tj = -7°C
3.94
2.66
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.30 kW
3.80 kW
COP Tj = +2°C
4.94
3.60
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
4.90 kW
4.90 kW
COP Tj = +7°C
6.27
4.80
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.80 kW
5.70 kW
COP Tj = 12°C
7.61
6.10
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
2.25
1.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.25
1.65
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4990 kWh
6939 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.30
7.30
COP Tj = -15°C (if TOL<-20°C)
3.00
2.21
Cdh Tj = -15 °C
0.990
0.990
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
197 %
140 %
Prated
9.00 kW
9.00 kW
SCOP
5.00
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.00 kW
8.00 kW
COP Tj = -7°C
3.52
2.53
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.90 kW
4.90 kW
COP Tj = +2°C
4.84
3.37
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
4.80 kW
4.70 kW
COP Tj = +7°C
6.15
4.53
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.80
5.90
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.19
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.19
2.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3721 kWh
5201 kWh
Agua caliente sanitaria
Clima cálido
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
134 %
COP
3.35
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
43.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima frío
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
88 %
COP
2.20
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
66.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
123 %
COP
3.00
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
44.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
9.00 kW
9.00 kW
Entrada EI
1.72 kW
2.78 kW
COP
5.23
3.24
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
2.49 kW
1.71 kW
Cooling capacity
9.00
9.00
EER
3.61
5.26
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
250 %
173 %
Prated
9.00 kW
9.00 kW
SCOP
6.33
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.00 kW
9.00 kW
COP Tj = +2°C
3.85
2.67
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.80 kW
5.80 kW
COP Tj = +7°C
5.89
3.81
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
5.70 kW
5.30 kW
COP Tj = 12°C
7.55
5.54
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.85
2.67
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.85
2.67
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
1901 kWh
2735 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
175 %
125 %
Prated
9.00 kW
9.00 kW
SCOP
4.45
3.20
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.50 kW
5.50 kW
COP Tj = -7°C
3.94
2.66
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.30 kW
3.80 kW
COP Tj = +2°C
4.94
3.60
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
4.90 kW
4.90 kW
COP Tj = +7°C
6.27
4.80
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.80 kW
5.70 kW
COP Tj = 12°C
7.61
6.10
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
2.25
1.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.25
1.65
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4990 kWh
6939 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.30
7.30
COP Tj = -15°C (if TOL<-20°C)
3.00
2.21
Cdh Tj = -15 °C
0.990
0.990
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
197 %
140 %
Prated
9.00 kW
9.00 kW
SCOP
5.00
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.00 kW
8.00 kW
COP Tj = -7°C
3.52
2.53
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.90 kW
4.90 kW
COP Tj = +2°C
4.84
3.37
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
4.80 kW
4.70 kW
COP Tj = +7°C
6.15
4.53
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.80
5.90
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.19
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.19
2.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3721 kWh
5201 kWh
Agua caliente sanitaria
Clima cálido
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
134 %
COP
3.35
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
43.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima frío
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
88 %
COP
2.20
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
66.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
123 %
COP
3.00
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
44.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
9.00 kW
9.00 kW
Entrada EI
1.72 kW
2.78 kW
COP
5.23
3.24
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
2.49 kW
1.71 kW
Cooling capacity
9.00
9.00
EER
3.61
5.26
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
250 %
173 %
Prated
9.00 kW
9.00 kW
SCOP
6.33
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.00 kW
9.00 kW
COP Tj = +2°C
3.85
2.67
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.80 kW
5.80 kW
COP Tj = +7°C
5.89
3.81
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
5.70 kW
5.30 kW
COP Tj = 12°C
7.55
5.54
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.85
2.67
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.85
2.67
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
1901 kWh
2735 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
175 %
125 %
Prated
9.00 kW
9.00 kW
SCOP
4.45
3.20
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.50 kW
5.50 kW
COP Tj = -7°C
3.94
2.66
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.30 kW
3.80 kW
COP Tj = +2°C
4.94
3.60
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
4.90 kW
4.90 kW
COP Tj = +7°C
6.27
4.80
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.80 kW
5.70 kW
COP Tj = 12°C
7.61
6.10
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
2.25
1.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.25
1.65
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4990 kWh
6939 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.30
7.30
COP Tj = -15°C (if TOL<-20°C)
3.00
2.21
Cdh Tj = -15 °C
0.990
0.990
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
197 %
140 %
Prated
9.00 kW
9.00 kW
SCOP
5.00
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.00 kW
8.00 kW
COP Tj = -7°C
3.52
2.53
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.90 kW
4.90 kW
COP Tj = +2°C
4.84
3.37
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
4.80 kW
4.70 kW
COP Tj = +7°C
6.15
4.53
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.80
5.90
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.19
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.19
2.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3721 kWh
5201 kWh
Agua caliente sanitaria
Clima cálido
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
134 %
COP
3.35
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
43.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima frío
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
88 %
COP
2.20
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
66.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
123 %
COP
3.00
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
44.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
9.00 kW
9.00 kW
Entrada EI
1.72 kW
2.78 kW
COP
5.23
3.24
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
2.49 kW
1.71 kW
Cooling capacity
9.00
9.00
EER
3.61
5.26
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
250 %
173 %
Prated
9.00 kW
9.00 kW
SCOP
6.33
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.00 kW
9.00 kW
COP Tj = +2°C
3.85
2.67
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.80 kW
5.80 kW
COP Tj = +7°C
5.89
3.81
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
5.70 kW
5.30 kW
COP Tj = 12°C
7.55
5.54
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.85
2.67
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.85
2.67
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
1901 kWh
2735 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
175 %
125 %
Prated
9.00 kW
9.00 kW
SCOP
4.45
3.20
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.50 kW
5.50 kW
COP Tj = -7°C
3.94
2.66
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.30 kW
3.80 kW
COP Tj = +2°C
4.94
3.60
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
4.90 kW
4.90 kW
COP Tj = +7°C
6.27
4.80
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.80 kW
5.70 kW
COP Tj = 12°C
7.61
6.10
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
2.25
1.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.25
1.65
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4990 kWh
6939 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.30
7.30
COP Tj = -15°C (if TOL<-20°C)
3.00
2.21
Cdh Tj = -15 °C
0.990
0.990
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
197 %
140 %
Prated
9.00 kW
9.00 kW
SCOP
5.00
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.00 kW
8.00 kW
COP Tj = -7°C
3.52
2.53
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.90 kW
4.90 kW
COP Tj = +2°C
4.84
3.37
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
4.80 kW
4.70 kW
COP Tj = +7°C
6.15
4.53
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.80
5.90
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.19
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.19
2.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3721 kWh
5201 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
9.00 kW
9.00 kW
Entrada EI
1.72 kW
2.78 kW
COP
5.23
3.24
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
2.49 kW
1.71 kW
Cooling capacity
9.00
9.00
EER
3.61
5.26
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
250 %
173 %
Prated
9.00 kW
9.00 kW
SCOP
6.33
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
9.00 kW
9.00 kW
COP Tj = +2°C
3.85
2.67
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.80 kW
5.80 kW
COP Tj = +7°C
5.89
3.81
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
5.70 kW
5.30 kW
COP Tj = 12°C
7.55
5.54
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.85
2.67
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.85
2.67
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
1901 kWh
2735 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
175 %
125 %
Prated
9.00 kW
9.00 kW
SCOP
4.45
3.20
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.50 kW
5.50 kW
COP Tj = -7°C
3.94
2.66
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.30 kW
3.80 kW
COP Tj = +2°C
4.94
3.60
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
4.90 kW
4.90 kW
COP Tj = +7°C
6.27
4.80
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.80 kW
5.70 kW
COP Tj = 12°C
7.61
6.10
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
2.25
1.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.25
1.65
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
4990 kWh
6939 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.30
7.30
COP Tj = -15°C (if TOL<-20°C)
3.00
2.21
Cdh Tj = -15 °C
0.990
0.990
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
35 dB(A)
35 dB(A)
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
197 %
140 %
Prated
9.00 kW
9.00 kW
SCOP
5.00
3.58
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.00 kW
8.00 kW
COP Tj = -7°C
3.52
2.53
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.90 kW
4.90 kW
COP Tj = +2°C
4.84
3.37
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
4.80 kW
4.70 kW
COP Tj = +7°C
6.15
4.53
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.80
5.90
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
9.00 kW
9.00 kW
COP Tj = Tbiv
3.19
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.00 kW
9.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.19
2.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3721 kWh
5201 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.37 kW
3.71 kW
COP
5.06
3.23
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
4.21 kW
2.80 kW
Cooling capacity
12.00
12.00
EER
2.85
4.29
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
245 %
173 %
Prated
12.00 kW
12.00 kW
SCOP
6.20
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.00 kW
12.00 kW
COP Tj = +2°C
3.53
2.51
Cdh Tj = +2 °C
0.990
1.000
Pdh Tj = +7°C
7.70 kW
7.70 kW
COP Tj = +7°C
5.62
3.94
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.54
5.36
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
3.53
2.51
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.53
2.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2586 kWh
3647 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
172 %
129 %
Prated
12.00 kW
10.00 kW
SCOP
4.38
3.30
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.30 kW
6.10 kW
COP Tj = -7°C
3.72
2.81
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.40 kW
3.70 kW
COP Tj = +2°C
4.95
3.75
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
5.30 kW
4.90 kW
COP Tj = +7°C
6.21
4.77
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.60 kW
5.70 kW
COP Tj = 12°C
7.54
6.03
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
10.00 kW
COP Tj = Tbiv
2.13
1.64
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
10.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.13
1.64
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
6758 kWh
7459 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.80
8.20
COP Tj = -15°C (if TOL<-20°C)
2.98
2.17
Cdh Tj = -15 °C
0.990
1.000
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
186 %
143 %
Prated
12.00 kW
12.00 kW
SCOP
4.73
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.60 kW
10.60 kW
COP Tj = -7°C
2.79
2.22
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
6.50 kW
6.50 kW
COP Tj = +2°C
4.65
3.65
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.30 kW
4.90 kW
COP Tj = +7°C
6.25
4.57
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
6.10 kW
5.70 kW
COP Tj = 12°C
7.78
5.84
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
2.91
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
5244 kWh
6792 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.37 kW
3.71 kW
COP
5.06
3.23
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
4.21 kW
2.80 kW
Cooling capacity
12.00
12.00
EER
2.85
4.29
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
245 %
173 %
Prated
12.00 kW
12.00 kW
SCOP
6.20
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.00 kW
12.00 kW
COP Tj = +2°C
3.53
2.51
Cdh Tj = +2 °C
0.990
1.000
Pdh Tj = +7°C
7.70 kW
7.70 kW
COP Tj = +7°C
5.62
3.94
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.54
5.36
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
3.53
2.51
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.53
2.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2586 kWh
3647 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
172 %
129 %
Prated
12.00 kW
10.00 kW
SCOP
4.38
3.30
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.30 kW
6.10 kW
COP Tj = -7°C
3.72
2.81
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.40 kW
3.70 kW
COP Tj = +2°C
4.95
3.75
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
5.30 kW
4.90 kW
COP Tj = +7°C
6.21
4.77
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.60 kW
5.70 kW
COP Tj = 12°C
7.54
6.03
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
10.00 kW
COP Tj = Tbiv
2.13
1.64
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
10.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.13
1.64
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
6758 kWh
7459 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.80
8.20
COP Tj = -15°C (if TOL<-20°C)
2.98
2.17
Cdh Tj = -15 °C
0.990
1.000
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
186 %
143 %
Prated
12.00 kW
12.00 kW
SCOP
4.73
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.60 kW
10.60 kW
COP Tj = -7°C
2.79
2.22
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
6.50 kW
6.50 kW
COP Tj = +2°C
4.65
3.65
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.30 kW
4.90 kW
COP Tj = +7°C
6.25
4.57
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
6.10 kW
5.70 kW
COP Tj = 12°C
7.78
5.84
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
2.91
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
5244 kWh
6792 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.37 kW
3.71 kW
COP
5.06
3.23
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
4.21 kW
2.80 kW
Cooling capacity
12.00
12.00
EER
2.85
4.29
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
245 %
173 %
Prated
12.00 kW
12.00 kW
SCOP
6.20
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.00 kW
12.00 kW
COP Tj = +2°C
3.53
2.51
Cdh Tj = +2 °C
0.990
1.000
Pdh Tj = +7°C
7.70 kW
7.70 kW
COP Tj = +7°C
5.62
3.94
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.54
5.36
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
3.53
2.51
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.53
2.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2586 kWh
3647 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
172 %
129 %
Prated
12.00 kW
10.00 kW
SCOP
4.38
3.30
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.30 kW
6.10 kW
COP Tj = -7°C
3.72
2.81
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.40 kW
3.70 kW
COP Tj = +2°C
4.95
3.75
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
5.30 kW
4.90 kW
COP Tj = +7°C
6.21
4.77
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.60 kW
5.70 kW
COP Tj = 12°C
7.54
6.03
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
10.00 kW
COP Tj = Tbiv
2.13
1.64
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
10.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.13
1.64
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
6758 kWh
7459 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.80
8.20
COP Tj = -15°C (if TOL<-20°C)
2.98
2.17
Cdh Tj = -15 °C
0.990
1.000
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
186 %
143 %
Prated
12.00 kW
12.00 kW
SCOP
4.73
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.60 kW
10.60 kW
COP Tj = -7°C
2.79
2.22
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
6.50 kW
6.50 kW
COP Tj = +2°C
4.65
3.65
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.30 kW
4.90 kW
COP Tj = +7°C
6.25
4.57
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
6.10 kW
5.70 kW
COP Tj = 12°C
7.78
5.84
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
2.91
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
5244 kWh
6792 kWh
Agua caliente sanitaria
Clima cálido
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
134 %
COP
3.35
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
43.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima frío
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
88 %
COP
2.20
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
66.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
123 %
COP
3.00
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
44.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.37 kW
3.71 kW
COP
5.06
3.23
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
4.21 kW
2.80 kW
Cooling capacity
12.00
12.00
EER
2.85
4.29
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
245 %
173 %
Prated
12.00 kW
12.00 kW
SCOP
6.20
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.00 kW
12.00 kW
COP Tj = +2°C
3.53
2.51
Cdh Tj = +2 °C
0.990
1.000
Pdh Tj = +7°C
7.70 kW
7.70 kW
COP Tj = +7°C
5.62
3.94
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.54
5.36
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
3.53
2.51
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.53
2.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2586 kWh
3647 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
172 %
129 %
Prated
12.00 kW
10.00 kW
SCOP
4.38
3.30
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.30 kW
6.10 kW
COP Tj = -7°C
3.72
2.81
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.40 kW
3.70 kW
COP Tj = +2°C
4.95
3.75
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
5.30 kW
4.90 kW
COP Tj = +7°C
6.21
4.77
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.60 kW
5.70 kW
COP Tj = 12°C
7.54
6.03
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
10.00 kW
COP Tj = Tbiv
2.13
1.64
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
10.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.13
1.64
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
6758 kWh
7459 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.80
8.20
COP Tj = -15°C (if TOL<-20°C)
2.98
2.17
Cdh Tj = -15 °C
0.990
1.000
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
186 %
143 %
Prated
12.00 kW
12.00 kW
SCOP
4.73
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.60 kW
10.60 kW
COP Tj = -7°C
2.79
2.22
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
6.50 kW
6.50 kW
COP Tj = +2°C
4.65
3.65
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.30 kW
4.90 kW
COP Tj = +7°C
6.25
4.57
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
6.10 kW
5.70 kW
COP Tj = 12°C
7.78
5.84
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
2.91
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
5244 kWh
6792 kWh
Agua caliente sanitaria
Clima cálido
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
134 %
COP
3.35
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
43.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima frío
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
88 %
COP
2.20
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
66.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
123 %
COP
3.00
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
44.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.37 kW
3.71 kW
COP
5.06
3.23
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
4.21 kW
2.80 kW
Cooling capacity
12.00
12.00
EER
2.85
4.29
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
245 %
173 %
Prated
12.00 kW
12.00 kW
SCOP
6.20
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.00 kW
12.00 kW
COP Tj = +2°C
3.53
2.51
Cdh Tj = +2 °C
0.990
1.000
Pdh Tj = +7°C
7.70 kW
7.70 kW
COP Tj = +7°C
5.62
3.94
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.54
5.36
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
3.53
2.51
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.53
2.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2586 kWh
3647 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
172 %
129 %
Prated
12.00 kW
10.00 kW
SCOP
4.38
3.30
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.30 kW
6.10 kW
COP Tj = -7°C
3.72
2.81
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.40 kW
3.70 kW
COP Tj = +2°C
4.95
3.75
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
5.30 kW
4.90 kW
COP Tj = +7°C
6.21
4.77
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.60 kW
5.70 kW
COP Tj = 12°C
7.54
6.03
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
10.00 kW
COP Tj = Tbiv
2.13
1.64
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
10.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.13
1.64
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
6758 kWh
7459 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.80
8.20
COP Tj = -15°C (if TOL<-20°C)
2.98
2.17
Cdh Tj = -15 °C
0.990
1.000
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
186 %
143 %
Prated
12.00 kW
12.00 kW
SCOP
4.73
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.60 kW
10.60 kW
COP Tj = -7°C
2.79
2.22
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
6.50 kW
6.50 kW
COP Tj = +2°C
4.65
3.65
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.30 kW
4.90 kW
COP Tj = +7°C
6.25
4.57
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
6.10 kW
5.70 kW
COP Tj = 12°C
7.78
5.84
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
2.91
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
5244 kWh
6792 kWh
Agua caliente sanitaria
Clima cálido
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
134 %
COP
3.35
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
43.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima frío
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
88 %
COP
2.20
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
66.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
123 %
COP
3.00
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
44.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.37 kW
3.71 kW
COP
5.06
3.23
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
4.21 kW
2.80 kW
Cooling capacity
12.00
12.00
EER
2.85
4.29
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
245 %
173 %
Prated
12.00 kW
12.00 kW
SCOP
6.20
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.00 kW
12.00 kW
COP Tj = +2°C
3.53
2.51
Cdh Tj = +2 °C
0.990
1.000
Pdh Tj = +7°C
7.70 kW
7.70 kW
COP Tj = +7°C
5.62
3.94
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.54
5.36
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
3.53
2.51
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.53
2.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2586 kWh
3647 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
172 %
129 %
Prated
12.00 kW
10.00 kW
SCOP
4.38
3.30
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.30 kW
6.10 kW
COP Tj = -7°C
3.72
2.81
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.40 kW
3.70 kW
COP Tj = +2°C
4.95
3.75
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
5.30 kW
4.90 kW
COP Tj = +7°C
6.21
4.77
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.60 kW
5.70 kW
COP Tj = 12°C
7.54
6.03
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
10.00 kW
COP Tj = Tbiv
2.13
1.64
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
10.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.13
1.64
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
6758 kWh
7459 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.80
8.20
COP Tj = -15°C (if TOL<-20°C)
2.98
2.17
Cdh Tj = -15 °C
0.990
1.000
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
186 %
143 %
Prated
12.00 kW
12.00 kW
SCOP
4.73
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.60 kW
10.60 kW
COP Tj = -7°C
2.79
2.22
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
6.50 kW
6.50 kW
COP Tj = +2°C
4.65
3.65
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.30 kW
4.90 kW
COP Tj = +7°C
6.25
4.57
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
6.10 kW
5.70 kW
COP Tj = 12°C
7.78
5.84
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
2.91
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
5244 kWh
6792 kWh
Agua caliente sanitaria
Clima cálido
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
134 %
COP
3.35
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
43.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima frío
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
88 %
COP
2.20
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
66.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
123 %
COP
3.00
Tiempo de calentamiento
0:56 h:min
Entrada de alimentación ( stand By )
44.0 W
Temperatura de referencia ACS
53.0 °C
Mezcla de agua a 40ºC
246 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.37 kW
3.71 kW
COP
5.06
3.23
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
4.21 kW
2.80 kW
Cooling capacity
12.00
12.00
EER
2.85
4.29
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
245 %
173 %
Prated
12.00 kW
12.00 kW
SCOP
6.20
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.00 kW
12.00 kW
COP Tj = +2°C
3.53
2.51
Cdh Tj = +2 °C
0.990
1.000
Pdh Tj = +7°C
7.70 kW
7.70 kW
COP Tj = +7°C
5.62
3.94
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.54
5.36
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
3.53
2.51
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.53
2.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2586 kWh
3647 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
172 %
129 %
Prated
12.00 kW
10.00 kW
SCOP
4.38
3.30
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.30 kW
6.10 kW
COP Tj = -7°C
3.72
2.81
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.40 kW
3.70 kW
COP Tj = +2°C
4.95
3.75
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
5.30 kW
4.90 kW
COP Tj = +7°C
6.21
4.77
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.60 kW
5.70 kW
COP Tj = 12°C
7.54
6.03
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
10.00 kW
COP Tj = Tbiv
2.13
1.64
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
10.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.13
1.64
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
6758 kWh
7459 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.80
8.20
COP Tj = -15°C (if TOL<-20°C)
2.98
2.17
Cdh Tj = -15 °C
0.990
1.000
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
186 %
143 %
Prated
12.00 kW
12.00 kW
SCOP
4.73
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.60 kW
10.60 kW
COP Tj = -7°C
2.79
2.22
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
6.50 kW
6.50 kW
COP Tj = +2°C
4.65
3.65
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.30 kW
4.90 kW
COP Tj = +7°C
6.25
4.57
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
6.10 kW
5.70 kW
COP Tj = 12°C
7.78
5.84
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
2.91
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
5244 kWh
6792 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.00 kW
12.00 kW
Entrada EI
2.37 kW
3.71 kW
COP
5.06
3.23
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Refrigeración
EN 14511-2
+7°C/+12°C
+18°C/+23°C
Entrada EI
4.21 kW
2.80 kW
Cooling capacity
12.00
12.00
EER
2.85
4.29
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
9.00 kW
9.00 kW
SEER
5.34
7.53
Pdc Tj = 35°C
9.00 kW
9.00 kW
EER Tj = 35°C
3.61
5.26
Cdc Tj = 35 °C
1.000
0.990
Pdc Tj = 30°C
6.63 kW
6.63 kW
EER Tj = 30°C
4.72
6.96
Cdc Tj = 30 °C
1.000
0.990
Pdc Tj = 25°C
4.72 kW
6.03 kW
EER Tj = 25°C
5.95
8.46
Cdc Tj = 25 °C
0.990
0.990
Pdc Tj = 20°C
4.84 kW
5.94 kW
EER Tj = 20°C
7.18
10.20
Cdc Tj = 20 °C
0.990
0.990
Poff
11 W
11 W
PTO
7 W
7 W
PSB
11 W
11 W
PCK
0 W
0 W
Consumo annual de enertía QCE
589 kWh
419 kWh
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
245 %
173 %
Prated
12.00 kW
12.00 kW
SCOP
6.20
4.40
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.00 kW
12.00 kW
COP Tj = +2°C
3.53
2.51
Cdh Tj = +2 °C
0.990
1.000
Pdh Tj = +7°C
7.70 kW
7.70 kW
COP Tj = +7°C
5.62
3.94
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
5.70 kW
5.60 kW
COP Tj = 12°C
7.54
5.36
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
3.53
2.51
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.53
2.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2586 kWh
3647 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
172 %
129 %
Prated
12.00 kW
10.00 kW
SCOP
4.38
3.30
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.30 kW
6.10 kW
COP Tj = -7°C
3.72
2.81
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.40 kW
3.70 kW
COP Tj = +2°C
4.95
3.75
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
5.30 kW
4.90 kW
COP Tj = +7°C
6.21
4.77
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
5.60 kW
5.70 kW
COP Tj = 12°C
7.54
6.03
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
10.00 kW
COP Tj = Tbiv
2.13
1.64
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
10.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.13
1.64
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
6758 kWh
7459 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.80
8.20
COP Tj = -15°C (if TOL<-20°C)
2.98
2.17
Cdh Tj = -15 °C
0.990
1.000
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
53 dB(A)
53 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
186 %
143 %
Prated
12.00 kW
12.00 kW
SCOP
4.73
3.65
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.60 kW
10.60 kW
COP Tj = -7°C
2.79
2.22
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
6.50 kW
6.50 kW
COP Tj = +2°C
4.65
3.65
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.30 kW
4.90 kW
COP Tj = +7°C
6.25
4.57
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
6.10 kW
5.70 kW
COP Tj = 12°C
7.78
5.84
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
12.00 kW
12.00 kW
COP Tj = Tbiv
2.91
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
18 W
18 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
5244 kWh
6792 kWh