2,150 kg
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
7.96 kW
6.48 kW
Entrada EI
1.51 kW
1.93 kW
COP
5.29
3.36
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
257 %
190 %
Prated
10.29 kW
11.05 kW
SCOP
6.50
4.82
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.29 kW
11.05 kW
COP Tj = +2°C
3.91
2.87
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
6.51 kW
7.16 kW
COP Tj = +7°C
6.06
4.17
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
6.04 kW
5.93 kW
COP Tj = 12°C
8.17
6.10
Cdh Tj = +12 °C
0.940
0.980
Pdh Tj = Tbiv
10.29 kW
11.05 kW
COP Tj = Tbiv
3.91
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.29 kW
11.05 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.91
2.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
75 °C
75 °C
Poff
13 W
13 W
PTO
43 W
22 W
PSB
13 W
13 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2114 kWh
3062 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
162 %
138 %
Prated
19.13 kW
20.29 kW
SCOP
4.12
3.52
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
11.56 kW
12.31 kW
COP Tj = -7°C
3.27
2.82
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.09 kW
7.54 kW
COP Tj = +2°C
5.08
4.17
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.34 kW
5.24 kW
COP Tj = +7°C
7.30
6.08
Cdh Tj = +7 °C
0.940
0.970
Pdh Tj = 12°C
6.06 kW
6.08 kW
COP Tj = 12°C
8.54
7.23
Cdh Tj = +12 °C
0.940
0.970
Pdh Tj = Tbiv
15.61 kW
16.55 kW
COP Tj = Tbiv
2.44
2.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.58 kW
13.76 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.24
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
75 °C
75 °C
Poff
13 W
13 W
PTO
43 W
22 W
PSB
13 W
13 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
7.55 kW
6.53 kW
Consumo annual de energia QHE
11452 kWh
14219 kWh
Pdh Tj = -15°C (if TOL<-20°C)
15.61
16.55
COP Tj = -15°C (if TOL<-20°C)
2.44
2.21
Cdh Tj = -15 °C
0.900
0.900
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
179 %
150 %
Prated
20.29 kW
20.25 kW
SCOP
4.55
3.89
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
17.95 kW
17.91 kW
COP Tj = -7°C
2.65
2.31
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
10.94 kW
10.84 kW
COP Tj = +2°C
4.21
3.58
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
6.92 kW
7.03 kW
COP Tj = +7°C
6.90
5.48
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
6.07 kW
6.05 kW
COP Tj = 12°C
8.74
7.01
Cdh Tj = +12 °C
0.940
0.970
Pdh Tj = Tbiv
17.95 kW
17.91 kW
COP Tj = Tbiv
2.65
2.31
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
17.09 kW
17.52 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.50
2.19
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
75 °C
75 °C
Poff
13 W
13 W
PTO
43 W
22 W
PSB
13 W
13 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
3.20 kW
2.73 kW
Consumo annual de energia QHE
9216 kWh
10918 kWh