4,000 kg
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
22.67 kW
36.62 kW
Entrada EI
4.44 kW
12.44 kW
COP
5.11
2.94
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
54 dB(A)
54 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
244 %
181 %
Prated
36.00 kW
35.00 kW
SCOP
6.18
4.59
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
35.41 kW
35.03 kW
COP Tj = +2°C
3.40
2.44
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
22.34 kW
22.62 kW
COP Tj = +7°C
5.80
3.96
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
21.43 kW
20.73 kW
COP Tj = 12°C
7.33
5.90
Cdh Tj = +12 °C
0.989
0.991
Pdh Tj = Tbiv
35.41 kW
35.03 kW
COP Tj = Tbiv
3.40
2.44
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
35.41 kW
35.03 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.40
2.44
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
70 °C
70 °C
Poff
24 W
24 W
PTO
41 W
41 W
PSB
41 W
41 W
PCK
38 W
38 W
Calentador suplementario: tipo de energía de entrada
n/a
n/a
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
7781 kWh
10189 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
54 dB(A)
54 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
162 %
127 %
Prated
30.00 kW
31.00 kW
SCOP
4.12
3.26
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
23.64 kW
23.37 kW
COP Tj = -7°C
3.54
2.73
Cdh Tj = -7 °C
0.985
0.988
Pdh Tj = +2°C
19.80 kW
18.83 kW
COP Tj = +2°C
4.68
3.73
Cdh Tj = +2 °C
0.976
0.980
Pdh Tj = +7°C
18.94 kW
18.54 kW
COP Tj = +7°C
6.51
5.40
Cdh Tj = +7 °C
0.988
0.990
Pdh Tj = 12°C
21.43 kW
21.15 kW
COP Tj = 12°C
7.43
6.67
Cdh Tj = +12 °C
0.988
0.989
Pdh Tj = Tbiv
30.05 kW
31.19 kW
COP Tj = Tbiv
2.05
1.62
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
30.05 kW
31.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.05
1.62
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
70 °C
70 °C
Poff
24 W
24 W
PTO
41 W
41 W
PSB
41 W
41 W
PCK
38 W
38 W
Calentador suplementario: tipo de energía de entrada
n/a
n/a
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
17938 kWh
23469 kWh
Pdh Tj = -15°C (if TOL<-20°C)
24.28
25.50
COP Tj = -15°C (if TOL<-20°C)
2.76
2.06
Cdh Tj = -15 °C
1.000
1.000
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
54 dB(A)
54 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
186 %
149 %
Prated
39.50 kW
40.00 kW
SCOP
4.72
3.80
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-22 °C
Pdh Tj = -7°C
33.43 kW
34.03 kW
COP Tj = -7°C
2.98
2.23
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
19.36 kW
21.06 kW
COP Tj = +2°C
4.59
3.72
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
18.47 kW
18.19 kW
COP Tj = +7°C
6.22
5.08
Cdh Tj = +7 °C
0.989
0.991
Pdh Tj = 12°C
20.98 kW
21.00 kW
COP Tj = 12°C
7.33
6.42
Cdh Tj = +12 °C
0.988
0.990
Pdh Tj = Tbiv
38.42 kW
39.31 kW
COP Tj = Tbiv
2.46
1.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
38.42 kW
39.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.46
1.91
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
70 °C
70 °C
Poff
24 W
24 W
PTO
41 W
41 W
PSB
41 W
41 W
PCK
38 W
38 W
Calentador suplementario: tipo de energía de entrada
n/a
n/a
Calentador suplementario: PSUP
0.00 kW
0.69 kW
Consumo annual de energia QHE
17287 kWh
21762 kWh