1,250 kg
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.0 kW
12.0 kW
Entrada EI
2.50 kW
3.87 kW
COP
4.80
3.10
EN 14511-4
cortando la trasferencia de calor de caudal medio
caducado
Fallo completo de alimentación eléctrica
caducado
Test de desescarche
caducado
Starting and operating test
caducado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
65 dB(A)
65 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
232 %
174 %
Prated
11.70 kW
12.40 kW
SCOP
5.90
4.45
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.58 kW
11.41 kW
COP Tj = +2°C
3.30
2.55
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.57 kW
7.85 kW
COP Tj = +7°C
5.78
3.99
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.17 kW
5.47 kW
COP Tj = 12°C
6.98
5.90
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.57 kW
7.85 kW
COP Tj = Tbiv
5.78
3.99
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.58 kW
11.41 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.30
2.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
75 °C
75 °C
Poff
9 W
9 W
PTO
14 W
14 W
PSB
9 W
9 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.12 kW
0.99 kW
Consumo annual de energia QHE
2651 kWh
3724 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
65 dB(A)
65 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
162 %
127 %
Prated
11.5 kW
10.8 kW
SCOP
4.13
3.26
Tbiv
-15.00 °C
-15.00 °C
TOL
-22.00 °C
-22.00 °C
Pdh Tj = -7°C
7.11 kW
6.76 kW
COP Tj = -7°C
3.47
2.72
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
4.33 kW
4.14 kW
COP Tj = +2°C
5.18
4.05
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.08 kW
5.00 kW
COP Tj = +7°C
6.46
5.15
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
5.15 kW
5.01 kW
COP Tj = 12°C
6.84
5.66
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
9.39 kW
8.84 kW
COP Tj = Tbiv
2.49
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.70 kW
6.84 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.04
1.52
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14 W
14 W
PSB
9.00 W
9.00 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
3.80 kW
3.96 kW
Consumo annual de energia QHE
6869.00 kWh
8197.00 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.39
8.84
COP Tj = -15°C (if TOL<-20°C)
2.49
1.98
Cdh Tj = -15 °C
0.9
0.9
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
65 dB(A)
65 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
183 %
141 %
Prated
12.1 kW
12.0 kW
SCOP
4.67
3.62
Tbiv
-7 °C
-7 °C
TOL
-10.00 °C
-10.00 °C
Pdh Tj = -7°C
10.75 kW
10.58 kW
COP Tj = -7°C
2.78
2.23
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
6.73 kW
6.59 kW
COP Tj = +2°C
4.55
3.52
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.23 kW
4.78 kW
COP Tj = +7°C
6.89
4.99
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
5.34 kW
5.59 kW
COP Tj = 12°C
7.41
6.41
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
10.75 kW
10.58 kW
COP Tj = Tbiv
2.78
2.23
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.77 kW
10.15 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.61
2.05
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14.00 W
14.00 W
PSB
9.00 W
9.00 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
1.33 kW
1.95 kW
Consumo annual de energia QHE
5352 kWh
6843 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
14.0 kW
14.0 kW
Entrada EI
3.11 kW
4.67 kW
COP
4.50
3.00
EN 14511-4
cortando la trasferencia de calor de caudal medio
caducado
Fallo completo de alimentación eléctrica
caducado
Test de desescarche
caducado
Starting and operating test
caducado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
65 dB(A)
65 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
231.00 %
174.00 %
Prated
12.7 kW
14.1 kW
SCOP
5.85
4.43
Tbiv
7.00 °C
7.00 °C
TOL
2.00 °C
2.00 °C
Pdh Tj = +2°C
12.41 kW
12.05 kW
COP Tj = +2°C
3.21
2.48
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
8.19 kW
9.11 kW
COP Tj = +7°C
5.67
3.98
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
5.17 kW
5.49 kW
COP Tj = 12°C
7.02
6.01
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
8.19 kW
9.11 kW
COP Tj = Tbiv
5.67
3.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.41 kW
12.05 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.21
2.48
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14.00 W
14.00 W
PSB
9 W
9 W
PCK
0.00 W
0.00 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.29 kW
2.21 kW
Consumo annual de energia QHE
2897.00 kWh
4256.00 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
65 dB(A)
65 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
162 %
126 %
Prated
12.6 kW
12.0 kW
SCOP
4.13
3.23
Tbiv
-15.00 °C
-15.00 °C
TOL
-22.00 °C
-22.00 °C
Pdh Tj = -7°C
7.83 kW
7.39 kW
COP Tj = -7°C
3.35
2.67
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
4.77 kW
4.56 kW
COP Tj = +2°C
5.37
4.00
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.08 kW
4.99 kW
COP Tj = +7°C
6.50
5.20
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
5.15 kW
5.06 kW
COP Tj = 12°C
6.85
5.81
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
10.31 kW
9.77 kW
COP Tj = Tbiv
2.39
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.57 kW
7.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.01
1.53
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14 W
14 W
PSB
9.00 W
9.00 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
4.03 kW
4.37 kW
Consumo annual de energia QHE
7513.00 kWh
9168.00 kWh
Pdh Tj = -15°C (if TOL<-20°C)
10.31
9.77
COP Tj = -15°C (if TOL<-20°C)
2.39
1.95
Cdh Tj = -15 °C
0.9
0.9
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
65 dB(A)
65 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
182 %
141 %
Prated
13.7 kW
13.0 kW
SCOP
4.63
3.61
Tbiv
-7 °C
-7 °C
TOL
-10.00 °C
-10.00 °C
Pdh Tj = -7°C
12.08 kW
11.47 kW
COP Tj = -7°C
2.66
2.15
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
7.55 kW
7.29 kW
COP Tj = +2°C
4.45
3.50
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.25 kW
4.85 kW
COP Tj = +7°C
7.06
5.10
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
5.23 kW
5.60 kW
COP Tj = 12°C
7.46
6.46
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
12.08 kW
11.47 kW
COP Tj = Tbiv
2.66
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.62 kW
10.97 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.53
2.02
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14.00 W
14.00 W
PSB
9.00 W
9.00 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
2.08 kW
2.03 kW
Consumo annual de energia QHE
6110 kWh
7438 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
15.0 kW
15.0 kW
Entrada EI
3.41 kW
5.26 kW
COP
4.40
2.85
EN 14511-4
cortando la trasferencia de calor de caudal medio
caducado
Fallo completo de alimentación eléctrica
caducado
Test de desescarche
caducado
Starting and operating test
caducado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
69 dB(A)
69 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
238.00 %
181.00 %
Prated
14.3 kW
14.9 kW
SCOP
6.05
4.62
Tbiv
7.00 °C
7.00 °C
TOL
2.00 °C
2.00 °C
Pdh Tj = +2°C
13.82 kW
13.47 kW
COP Tj = +2°C
3.18
2.48
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
9.17 kW
9.58 kW
COP Tj = +7°C
5.82
4.04
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
5.34 kW
5.64 kW
COP Tj = 12°C
7.33
6.31
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
9.17 kW
9.58 kW
COP Tj = Tbiv
5.82
4.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.82 kW
13.47 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.18
2.48
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14.00 W
14.00 W
PSB
9 W
9 W
PCK
0.00 W
0.00 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.48 kW
1.43 kW
Consumo annual de energia QHE
3159.00 kWh
4306.00 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
69 dB(A)
69 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
160 %
128 %
Prated
14.6 kW
13.9 kW
SCOP
4.08
3.29
Tbiv
-15.00 °C
-15.00 °C
TOL
-22.00 °C
-22.00 °C
Pdh Tj = -7°C
8.89 kW
8.30 kW
COP Tj = -7°C
3.25
2.70
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
5.87 kW
5.18 kW
COP Tj = +2°C
5.22
4.03
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.24 kW
5.17 kW
COP Tj = +7°C
6.67
5.44
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
5.32 kW
5.23 kW
COP Tj = 12°C
7.26
6.07
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
11.91 kW
11.32 kW
COP Tj = Tbiv
2.41
1.97
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.06 kW
9.07 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.02
1.56
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14 W
14 W
PSB
9.00 W
9.00 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
4.54 kW
4.83 kW
Consumo annual de energia QHE
8813.00 kWh
10408.00 kWh
Pdh Tj = -15°C (if TOL<-20°C)
11.91
11.32
COP Tj = -15°C (if TOL<-20°C)
2.41
1.97
Cdh Tj = -15 °C
0.9
0.9
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
69 dB(A)
69 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
180 %
139 %
Prated
14.7 kW
14.4 kW
SCOP
4.59
3.57
Tbiv
-7 °C
-7 °C
TOL
-10.00 °C
-10.00 °C
Pdh Tj = -7°C
13.04 kW
12.78 kW
COP Tj = -7°C
2.54
2.05
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
8.00 kW
7.96 kW
COP Tj = +2°C
4.40
3.44
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.26 kW
4.78 kW
COP Tj = +7°C
7.12
5.13
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
5.28 kW
5.72 kW
COP Tj = 12°C
7.56
6.58
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
13.04 kW
12.78 kW
COP Tj = Tbiv
2.54
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.81 kW
12.54 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.37
1.94
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14.00 W
14.00 W
PSB
9.00 W
9.00 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
1.89 kW
1.86 kW
Consumo annual de energia QHE
6617 kWh
8349 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
12.0 kW
12.0 kW
Entrada EI
2.50 kW
3.87 kW
COP
4.80
3.10
EN 14511-4
cortando la trasferencia de calor de caudal medio
caducado
Fallo completo de alimentación eléctrica
caducado
Test de desescarche
caducado
Starting and operating test
caducado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
65 dB(A)
65 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
232 %
174 %
Prated
11.70 kW
12.40 kW
SCOP
5.90
4.45
Tbiv
7 °C
7 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.58 kW
11.41 kW
COP Tj = +2°C
3.30
2.55
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.57 kW
7.85 kW
COP Tj = +7°C
5.78
3.99
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.17 kW
5.47 kW
COP Tj = 12°C
6.98
5.90
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.57 kW
7.85 kW
COP Tj = Tbiv
5.78
3.99
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.58 kW
11.41 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.30
2.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
75 °C
75 °C
Poff
9 W
9 W
PTO
14 W
14 W
PSB
9 W
9 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.12 kW
0.99 kW
Consumo annual de energia QHE
2651 kWh
3724 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
65 dB(A)
65 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
162 %
127 %
Prated
11.5 kW
10.8 kW
SCOP
4.13
3.26
Tbiv
-15.00 °C
-15.00 °C
TOL
-22.00 °C
-22.00 °C
Pdh Tj = -7°C
7.11 kW
6.76 kW
COP Tj = -7°C
3.47
2.72
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
4.33 kW
4.14 kW
COP Tj = +2°C
5.18
4.05
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.08 kW
5.00 kW
COP Tj = +7°C
6.46
5.15
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
5.15 kW
5.01 kW
COP Tj = 12°C
6.84
5.66
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
9.39 kW
8.84 kW
COP Tj = Tbiv
2.49
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.70 kW
6.84 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.04
1.52
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14 W
14 W
PSB
9.00 W
9.00 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
3.80 kW
3.96 kW
Consumo annual de energia QHE
6869.00 kWh
8197.00 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.39
8.84
COP Tj = -15°C (if TOL<-20°C)
2.49
1.98
Cdh Tj = -15 °C
0.9
0.9
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
65 dB(A)
65 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
183 %
141 %
Prated
12.1 kW
12.0 kW
SCOP
4.67
3.62
Tbiv
-7 °C
-7 °C
TOL
-10.00 °C
-10.00 °C
Pdh Tj = -7°C
10.75 kW
10.58 kW
COP Tj = -7°C
2.78
2.23
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
6.73 kW
6.59 kW
COP Tj = +2°C
4.55
3.52
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.23 kW
4.78 kW
COP Tj = +7°C
6.89
4.99
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
5.34 kW
5.59 kW
COP Tj = 12°C
7.41
6.41
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
10.75 kW
10.58 kW
COP Tj = Tbiv
2.78
2.23
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.77 kW
10.15 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.61
2.05
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14.00 W
14.00 W
PSB
9.00 W
9.00 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
1.33 kW
1.95 kW
Consumo annual de energia QHE
5352 kWh
6843 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
14.0 kW
14.0 kW
Entrada EI
3.11 kW
4.67 kW
COP
4.50
3.00
EN 14511-4
cortando la trasferencia de calor de caudal medio
caducado
Fallo completo de alimentación eléctrica
caducado
Test de desescarche
caducado
Starting and operating test
caducado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
65 dB(A)
65 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
231.00 %
174.00 %
Prated
12.7 kW
14.1 kW
SCOP
5.85
4.43
Tbiv
7.00 °C
7.00 °C
TOL
2.00 °C
2.00 °C
Pdh Tj = +2°C
12.41 kW
12.05 kW
COP Tj = +2°C
3.21
2.48
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
8.19 kW
9.11 kW
COP Tj = +7°C
5.67
3.98
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
5.17 kW
5.49 kW
COP Tj = 12°C
7.02
6.01
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
8.19 kW
9.11 kW
COP Tj = Tbiv
5.67
3.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.41 kW
12.05 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.21
2.48
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14.00 W
14.00 W
PSB
9 W
9 W
PCK
0.00 W
0.00 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.29 kW
2.21 kW
Consumo annual de energia QHE
2897.00 kWh
4256.00 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
65 dB(A)
65 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
162 %
126 %
Prated
12.6 kW
12.0 kW
SCOP
4.13
3.23
Tbiv
-15.00 °C
-15.00 °C
TOL
-22.00 °C
-22.00 °C
Pdh Tj = -7°C
7.83 kW
7.39 kW
COP Tj = -7°C
3.35
2.67
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
4.77 kW
4.56 kW
COP Tj = +2°C
5.37
4.00
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.08 kW
4.99 kW
COP Tj = +7°C
6.50
5.20
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
5.15 kW
5.06 kW
COP Tj = 12°C
6.85
5.81
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
10.31 kW
9.77 kW
COP Tj = Tbiv
2.39
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.57 kW
7.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.01
1.53
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14 W
14 W
PSB
9.00 W
9.00 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
4.03 kW
4.37 kW
Consumo annual de energia QHE
7513.00 kWh
9168.00 kWh
Pdh Tj = -15°C (if TOL<-20°C)
10.31
9.77
COP Tj = -15°C (if TOL<-20°C)
2.39
1.95
Cdh Tj = -15 °C
0.9
0.9
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
65 dB(A)
65 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
182 %
141 %
Prated
13.7 kW
13.0 kW
SCOP
4.63
3.61
Tbiv
-7 °C
-7 °C
TOL
-10.00 °C
-10.00 °C
Pdh Tj = -7°C
12.08 kW
11.47 kW
COP Tj = -7°C
2.66
2.15
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
7.55 kW
7.29 kW
COP Tj = +2°C
4.45
3.50
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.25 kW
4.85 kW
COP Tj = +7°C
7.06
5.10
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
5.23 kW
5.60 kW
COP Tj = 12°C
7.46
6.46
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
12.08 kW
11.47 kW
COP Tj = Tbiv
2.66
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.62 kW
10.97 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.53
2.02
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14.00 W
14.00 W
PSB
9.00 W
9.00 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
2.08 kW
2.03 kW
Consumo annual de energia QHE
6110 kWh
7438 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
15.0 kW
15.0 kW
Entrada EI
3.41 kW
5.26 kW
COP
4.40
2.85
EN 14511-4
cortando la trasferencia de calor de caudal medio
caducado
Fallo completo de alimentación eléctrica
caducado
Test de desescarche
caducado
Starting and operating test
caducado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
69 dB(A)
69 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
238.00 %
181.00 %
Prated
14.3 kW
14.9 kW
SCOP
6.05
4.62
Tbiv
7.00 °C
7.00 °C
TOL
2.00 °C
2.00 °C
Pdh Tj = +2°C
13.82 kW
13.47 kW
COP Tj = +2°C
3.18
2.48
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
9.17 kW
9.58 kW
COP Tj = +7°C
5.82
4.04
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
5.34 kW
5.64 kW
COP Tj = 12°C
7.33
6.31
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
9.17 kW
9.58 kW
COP Tj = Tbiv
5.82
4.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.82 kW
13.47 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.18
2.48
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14.00 W
14.00 W
PSB
9 W
9 W
PCK
0.00 W
0.00 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.48 kW
1.43 kW
Consumo annual de energia QHE
3159.00 kWh
4306.00 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
69 dB(A)
69 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
160 %
128 %
Prated
14.6 kW
13.9 kW
SCOP
4.08
3.29
Tbiv
-15.00 °C
-15.00 °C
TOL
-22.00 °C
-22.00 °C
Pdh Tj = -7°C
8.89 kW
8.30 kW
COP Tj = -7°C
3.25
2.70
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
5.87 kW
5.18 kW
COP Tj = +2°C
5.22
4.03
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.24 kW
5.17 kW
COP Tj = +7°C
6.67
5.44
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
5.32 kW
5.23 kW
COP Tj = 12°C
7.26
6.07
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
11.91 kW
11.32 kW
COP Tj = Tbiv
2.41
1.97
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.06 kW
9.07 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.02
1.56
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14 W
14 W
PSB
9.00 W
9.00 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
4.54 kW
4.83 kW
Consumo annual de energia QHE
8813.00 kWh
10408.00 kWh
Pdh Tj = -15°C (if TOL<-20°C)
11.91
11.32
COP Tj = -15°C (if TOL<-20°C)
2.41
1.97
Cdh Tj = -15 °C
0.9
0.9
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
69 dB(A)
69 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
180 %
139 %
Prated
14.7 kW
14.4 kW
SCOP
4.59
3.57
Tbiv
-7 °C
-7 °C
TOL
-10.00 °C
-10.00 °C
Pdh Tj = -7°C
13.04 kW
12.78 kW
COP Tj = -7°C
2.54
2.05
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
8.00 kW
7.96 kW
COP Tj = +2°C
4.40
3.44
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.26 kW
4.78 kW
COP Tj = +7°C
7.12
5.13
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
5.28 kW
5.72 kW
COP Tj = 12°C
7.56
6.58
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
13.04 kW
12.78 kW
COP Tj = Tbiv
2.54
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.81 kW
12.54 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.37
1.94
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14.00 W
14.00 W
PSB
9.00 W
9.00 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
1.89 kW
1.86 kW
Consumo annual de energia QHE
6617 kWh
8349 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
11.5 kW
11.5 kW
Entrada EI
2.37 kW
3.65 kW
COP
4.85
3.15
EN 14511-4
cortando la trasferencia de calor de caudal medio
caducado
Fallo completo de alimentación eléctrica
caducado
Test de desescarche
caducado
Starting and operating test
caducado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
187.8 %
147.1 %
Prated
12.1 kW
12.1 kW
SCOP
4.77
3.75
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.68 kW
10.88 kW
COP Tj = -7°C
2.8
2.27
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
6.69 kW
6.56 kW
COP Tj = +2°C
4.55
3.63
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
5.3 kW
4.78 kW
COP Tj = +7°C
6.98
4.99
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.34 kW
5.83 kW
COP Tj = 12°C
7.7
6.55
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
10.68 kW
10.88 kW
COP Tj = Tbiv
2.8
2.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.66 kW
10.71 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.61
2.15
WTOL
75 °C
75 °C
Poff
10.1 W
10.1 W
PTO
15 W
15 W
PSB
10.1 W
10.1 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
1.44 kW
1.39 kW
Consumo annual de energia QHE
5240 kWh
6662 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
11.5 kW
11.5 kW
Entrada EI
2.37 kW
3.65 kW
COP
4.85
3.15
EN 14511-4
cortando la trasferencia de calor de caudal medio
caducado
Fallo completo de alimentación eléctrica
caducado
Test de desescarche
caducado
Starting and operating test
caducado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
187.8 %
147.1 %
Prated
12.1 kW
12.1 kW
SCOP
4.77
3.75
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.68 kW
10.88 kW
COP Tj = -7°C
2.8
2.27
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
6.69 kW
6.56 kW
COP Tj = +2°C
4.55
3.63
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
5.3 kW
4.78 kW
COP Tj = +7°C
6.98
4.99
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
5.34 kW
5.83 kW
COP Tj = 12°C
7.7
6.55
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
10.68 kW
10.88 kW
COP Tj = Tbiv
2.8
2.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.66 kW
10.71 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.61
2.15
WTOL
75 °C
75 °C
Poff
10.1 W
10.1 W
PTO
15 W
15 W
PSB
10.1 W
10.1 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
1.44 kW
1.39 kW
Consumo annual de energia QHE
5240 kWh
6662 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
13.5 kW
13.5 kW
Entrada EI
2.93 kW
4.44 kW
COP
4.6
3.04
EN 14511-4
cortando la trasferencia de calor de caudal medio
caducado
Fallo completo de alimentación eléctrica
caducado
Test de desescarche
caducado
Starting and operating test
caducado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
184.9 %
146.2 %
Prated
13.7 kW
13.7 kW
SCOP
4.7
3.73
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.03 kW
11.87 kW
COP Tj = -7°C
2.7
2.22
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
7.38 kW
7.37 kW
COP Tj = +2°C
4.46
3.56
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
5.24 kW
4.87 kW
COP Tj = +7°C
7.02
5.21
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
5.28 kW
5.83 kW
COP Tj = 12°C
7.71
6.55
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
12.03 kW
11.87 kW
COP Tj = Tbiv
2.7
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.45 kW
11.2 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
2.07
WTOL
75 °C
75 °C
Poff
10.1 W
10.1 W
PTO
15 W
15 W
PSB
10.1 W
10.1 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
2.25 kW
2.5 kW
Consumo annual de energia QHE
6025 kWh
7588 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
13.5 kW
13.5 kW
Entrada EI
2.93 kW
4.44 kW
COP
4.6
3.04
EN 14511-4
cortando la trasferencia de calor de caudal medio
caducado
Fallo completo de alimentación eléctrica
caducado
Test de desescarche
caducado
Starting and operating test
caducado
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad exterior
52 dB(A)
52 dB(A)
EN 14825
Baja temperatura
Media temperatura
ηs
184.9 %
146.2 %
Prated
13.7 kW
13.7 kW
SCOP
4.7
3.73
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.03 kW
11.87 kW
COP Tj = -7°C
2.7
2.22
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
7.38 kW
7.37 kW
COP Tj = +2°C
4.46
3.56
Cdh Tj = +2 °C
1
1
Pdh Tj = +7°C
5.24 kW
4.87 kW
COP Tj = +7°C
7.02
5.21
Cdh Tj = +7 °C
1
1
Pdh Tj = 12°C
5.28 kW
5.83 kW
COP Tj = 12°C
7.71
6.55
Cdh Tj = +12 °C
0.99
0.99
Pdh Tj = Tbiv
12.03 kW
11.87 kW
COP Tj = Tbiv
2.7
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.45 kW
11.2 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.54
2.07
WTOL
75 °C
75 °C
Poff
10.1 W
10 W
PTO
15 W
10 W
PSB
10.1 W
10 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
2.25 kW
2.5 kW
Consumo annual de energia QHE
6025 kWh
7588 kWh