0,150 kg
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
2.58 kW
4.39 kW
Entrada EI
0.60 kW
1.53 kW
COP
4.30
2.84
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
178 %
132 %
Prated
6.20 kW
6.00 kW
SCOP
4.66
3.49
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.16 kW
5.63 kW
COP Tj = +2°C
3.72
2.87
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.86 kW
3.62 kW
COP Tj = +7°C
4.43
3.34
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.71 kW
3.51 kW
COP Tj = 12°C
5.37
4.32
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
1777 kWh
2299 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
186 %
144 %
Prated
6.20 kW
6.00 kW
SCOP
4.85
3.81
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.64 kW
3.42 kW
COP Tj = -7°C
4.59
3.49
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.24 kW
2.10 kW
COP Tj = +2°C
5.27
4.12
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
1.44 kW
1.43 kW
COP Tj = +7°C
5.40
4.48
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
0.88 kW
1.21 kW
COP Tj = 12°C
4.91
4.87
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3151 kWh
4011 kWh
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
180 %
142 %
Prated
6.20 kW
6.00 kW
SCOP
4.71
3.76
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.51 kW
5.06 kW
COP Tj = -7°C
4.10
3.06
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.33 kW
3.08 kW
COP Tj = +2°C
4.91
3.79
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.27 kW
1.89 kW
COP Tj = +7°C
5.05
4.25
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.73 kW
0.86 kW
COP Tj = 12°C
5.21
4.37
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2722 kWh
3300 kWh
Agua caliente sanitaria
Clima cálido
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
80 %
COP
1.82
Tiempo de calentamiento
1:50 h:min
Entrada de alimentación ( stand By )
100.0 W
Temperatura de referencia ACS
57.0 °C
Mezcla de agua a 40ºC
220 l
Clima frío
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
80 %
COP
1.82
Tiempo de calentamiento
1:50 h:min
Entrada de alimentación ( stand By )
100.0 W
Temperatura de referencia ACS
57.0 °C
Mezcla de agua a 40ºC
220 l
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
80 %
COP
1.82
Tiempo de calentamiento
1:50 h:min
Entrada de alimentación ( stand By )
100.0 W
Temperatura de referencia ACS
57.0 °C
Mezcla de agua a 40ºC
220 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
2.58 kW
4.39 kW
Entrada EI
0.60 kW
1.53 kW
COP
4.30
2.84
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
178 %
132 %
Prated
6.20 kW
6.00 kW
SCOP
4.66
3.49
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.16 kW
5.63 kW
COP Tj = +2°C
3.72
2.87
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.86 kW
3.62 kW
COP Tj = +7°C
4.43
3.34
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.71 kW
3.51 kW
COP Tj = 12°C
5.37
4.32
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
1777 kWh
2299 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
186 %
144 %
Prated
6.20 kW
6.00 kW
SCOP
4.85
3.81
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.64 kW
3.42 kW
COP Tj = -7°C
4.59
3.49
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.24 kW
2.10 kW
COP Tj = +2°C
5.27
4.12
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
1.44 kW
1.43 kW
COP Tj = +7°C
5.40
4.48
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
0.88 kW
1.21 kW
COP Tj = 12°C
4.91
4.87
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3151 kWh
4011 kWh
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
180 %
142 %
Prated
6.20 kW
6.00 kW
SCOP
4.71
3.76
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.51 kW
5.06 kW
COP Tj = -7°C
4.10
3.06
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.33 kW
3.08 kW
COP Tj = +2°C
4.91
3.79
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.27 kW
1.89 kW
COP Tj = +7°C
5.05
4.25
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.73 kW
0.86 kW
COP Tj = 12°C
5.21
4.37
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2722 kWh
3300 kWh
Agua caliente sanitaria
Clima cálido
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
80 %
COP
1.82
Tiempo de calentamiento
1:50 h:min
Entrada de alimentación ( stand By )
100.0 W
Temperatura de referencia ACS
57.0 °C
Mezcla de agua a 40ºC
220 l
Clima frío
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
80 %
COP
1.82
Tiempo de calentamiento
1:50 h:min
Entrada de alimentación ( stand By )
100.0 W
Temperatura de referencia ACS
57.0 °C
Mezcla de agua a 40ºC
220 l
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
80 %
COP
1.82
Tiempo de calentamiento
1:50 h:min
Entrada de alimentación ( stand By )
100.0 W
Temperatura de referencia ACS
57.0 °C
Mezcla de agua a 40ºC
220 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
2.58 kW
4.39 kW
Entrada EI
0.60 kW
1.53 kW
COP
4.30
2.84
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
178 %
132 %
Prated
6.20 kW
6.00 kW
SCOP
4.66
3.49
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.16 kW
5.63 kW
COP Tj = +2°C
3.72
2.87
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.86 kW
3.62 kW
COP Tj = +7°C
4.43
3.34
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.71 kW
3.51 kW
COP Tj = 12°C
5.37
4.32
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
1777 kWh
2299 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
186 %
144 %
Prated
6.20 kW
6.00 kW
SCOP
4.85
3.81
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.64 kW
3.42 kW
COP Tj = -7°C
4.59
3.49
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.24 kW
2.10 kW
COP Tj = +2°C
5.27
4.12
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
1.44 kW
1.43 kW
COP Tj = +7°C
5.40
4.48
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
0.88 kW
1.21 kW
COP Tj = 12°C
4.91
4.87
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3151 kWh
4011 kWh
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
180 %
142 %
Prated
6.20 kW
6.00 kW
SCOP
4.71
3.76
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.51 kW
5.06 kW
COP Tj = -7°C
4.10
3.06
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.33 kW
3.08 kW
COP Tj = +2°C
4.91
3.79
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.27 kW
1.89 kW
COP Tj = +7°C
5.05
4.25
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.73 kW
0.86 kW
COP Tj = 12°C
5.21
4.37
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2722 kWh
3300 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
2.58 kW
4.39 kW
Entrada EI
0.60 kW
1.53 kW
COP
4.30
2.84
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
178 %
132 %
Prated
6.20 kW
6.00 kW
SCOP
4.66
3.49
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.16 kW
5.63 kW
COP Tj = +2°C
3.72
2.87
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.86 kW
3.62 kW
COP Tj = +7°C
4.43
3.34
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.71 kW
3.51 kW
COP Tj = 12°C
5.37
4.32
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
1777 kWh
2299 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
186 %
144 %
Prated
6.20 kW
6.00 kW
SCOP
4.85
3.81
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.64 kW
3.42 kW
COP Tj = -7°C
4.59
3.49
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.24 kW
2.10 kW
COP Tj = +2°C
5.27
4.12
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
1.44 kW
1.43 kW
COP Tj = +7°C
5.40
4.48
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
0.88 kW
1.21 kW
COP Tj = 12°C
4.91
4.87
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3151 kWh
4011 kWh
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
180 %
142 %
Prated
6.20 kW
6.00 kW
SCOP
4.71
3.76
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.51 kW
5.06 kW
COP Tj = -7°C
4.10
3.06
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.33 kW
3.08 kW
COP Tj = +2°C
4.91
3.79
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.27 kW
1.89 kW
COP Tj = +7°C
5.05
4.25
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.73 kW
0.86 kW
COP Tj = 12°C
5.21
4.37
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2722 kWh
3300 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
2.58 kW
4.39 kW
Entrada EI
0.60 kW
1.53 kW
COP
4.30
2.84
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
178 %
132 %
Prated
6.20 kW
6.00 kW
SCOP
4.66
3.49
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.16 kW
5.63 kW
COP Tj = +2°C
3.72
2.87
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.86 kW
3.62 kW
COP Tj = +7°C
4.43
3.34
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.71 kW
3.51 kW
COP Tj = 12°C
5.37
4.32
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
1777 kWh
2299 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
186 %
144 %
Prated
6.20 kW
6.00 kW
SCOP
4.85
3.81
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.64 kW
3.42 kW
COP Tj = -7°C
4.59
3.49
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.24 kW
2.10 kW
COP Tj = +2°C
5.27
4.12
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
1.44 kW
1.43 kW
COP Tj = +7°C
5.40
4.48
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
0.88 kW
1.21 kW
COP Tj = 12°C
4.91
4.87
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3151 kWh
4011 kWh
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
180 %
142 %
Prated
6.20 kW
6.00 kW
SCOP
4.71
3.76
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.51 kW
5.06 kW
COP Tj = -7°C
4.10
3.06
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.33 kW
3.08 kW
COP Tj = +2°C
4.91
3.79
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.27 kW
1.89 kW
COP Tj = +7°C
5.05
4.25
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.73 kW
0.86 kW
COP Tj = 12°C
5.21
4.37
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2722 kWh
3300 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
2.58 kW
4.39 kW
Entrada EI
0.60 kW
1.53 kW
COP
4.30
2.84
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
178 %
132 %
Prated
6.20 kW
6.00 kW
SCOP
4.66
3.49
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.16 kW
5.63 kW
COP Tj = +2°C
3.72
2.87
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.86 kW
3.62 kW
COP Tj = +7°C
4.43
3.34
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.71 kW
3.51 kW
COP Tj = 12°C
5.37
4.32
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
1777 kWh
2299 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
186 %
144 %
Prated
6.20 kW
6.00 kW
SCOP
4.85
3.81
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.64 kW
3.42 kW
COP Tj = -7°C
4.59
3.49
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.24 kW
2.10 kW
COP Tj = +2°C
5.27
4.12
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
1.44 kW
1.43 kW
COP Tj = +7°C
5.40
4.48
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
0.88 kW
1.21 kW
COP Tj = 12°C
4.91
4.87
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3151 kWh
4011 kWh
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
180 %
142 %
Prated
6.20 kW
6.00 kW
SCOP
4.71
3.76
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.51 kW
5.06 kW
COP Tj = -7°C
4.10
3.06
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.33 kW
3.08 kW
COP Tj = +2°C
4.91
3.79
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.27 kW
1.89 kW
COP Tj = +7°C
5.05
4.25
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.73 kW
0.86 kW
COP Tj = 12°C
5.21
4.37
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2722 kWh
3300 kWh
Agua caliente sanitaria
Clima cálido
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
80 %
COP
1.82
Tiempo de calentamiento
1:50 h:min
Entrada de alimentación ( stand By )
100.0 W
Temperatura de referencia ACS
57.0 °C
Mezcla de agua a 40ºC
220 l
Clima frío
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
80 %
COP
1.82
Tiempo de calentamiento
1:50 h:min
Entrada de alimentación ( stand By )
100.0 W
Temperatura de referencia ACS
57.0 °C
Mezcla de agua a 40ºC
220 l
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
80 %
COP
1.82
Tiempo de calentamiento
1:50 h:min
Entrada de alimentación ( stand By )
100.0 W
Temperatura de referencia ACS
57.0 °C
Mezcla de agua a 40ºC
220 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
2.58 kW
4.39 kW
Entrada EI
0.60 kW
1.53 kW
COP
4.30
2.84
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
178 %
132 %
Prated
6.20 kW
6.00 kW
SCOP
4.66
3.49
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.16 kW
5.63 kW
COP Tj = +2°C
3.72
2.87
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.86 kW
3.62 kW
COP Tj = +7°C
4.43
3.34
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.71 kW
3.51 kW
COP Tj = 12°C
5.37
4.32
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
1777 kWh
2299 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
186 %
144 %
Prated
6.20 kW
6.00 kW
SCOP
4.85
3.81
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.64 kW
3.42 kW
COP Tj = -7°C
4.59
3.49
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.24 kW
2.10 kW
COP Tj = +2°C
5.27
4.12
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
1.44 kW
1.43 kW
COP Tj = +7°C
5.40
4.48
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
0.88 kW
1.21 kW
COP Tj = 12°C
4.91
4.87
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3151 kWh
4011 kWh
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
180 %
142 %
Prated
6.20 kW
6.00 kW
SCOP
4.71
3.76
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.51 kW
5.06 kW
COP Tj = -7°C
4.10
3.06
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.33 kW
3.08 kW
COP Tj = +2°C
4.91
3.79
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.27 kW
1.89 kW
COP Tj = +7°C
5.05
4.25
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.73 kW
0.86 kW
COP Tj = 12°C
5.21
4.37
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2722 kWh
3300 kWh
Agua caliente sanitaria
Clima cálido
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
80 %
COP
1.82
Tiempo de calentamiento
1:50 h:min
Entrada de alimentación ( stand By )
100.0 W
Temperatura de referencia ACS
57.0 °C
Mezcla de agua a 40ºC
220 l
Clima frío
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
80 %
COP
1.82
Tiempo de calentamiento
1:50 h:min
Entrada de alimentación ( stand By )
100.0 W
Temperatura de referencia ACS
57.0 °C
Mezcla de agua a 40ºC
220 l
Clima medio
EN 16147
Perfil de carga declarado
L
Eficiencia ηdhw
80 %
COP
1.82
Tiempo de calentamiento
1:50 h:min
Entrada de alimentación ( stand By )
100.0 W
Temperatura de referencia ACS
57.0 °C
Mezcla de agua a 40ºC
220 l
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
2.58 kW
4.39 kW
Entrada EI
0.60 kW
1.53 kW
COP
4.30
2.84
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
178 %
132 %
Prated
6.20 kW
6.00 kW
SCOP
4.66
3.49
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.16 kW
5.63 kW
COP Tj = +2°C
3.72
2.87
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.86 kW
3.62 kW
COP Tj = +7°C
4.43
3.34
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.71 kW
3.51 kW
COP Tj = 12°C
5.37
4.32
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
1777 kWh
2299 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
186 %
144 %
Prated
6.20 kW
6.00 kW
SCOP
4.85
3.81
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.64 kW
3.42 kW
COP Tj = -7°C
4.59
3.49
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.24 kW
2.10 kW
COP Tj = +2°C
5.27
4.12
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
1.44 kW
1.43 kW
COP Tj = +7°C
5.40
4.48
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
0.88 kW
1.21 kW
COP Tj = 12°C
4.91
4.87
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3151 kWh
4011 kWh
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
180 %
142 %
Prated
6.20 kW
6.00 kW
SCOP
4.71
3.76
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.51 kW
5.06 kW
COP Tj = -7°C
4.10
3.06
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.33 kW
3.08 kW
COP Tj = +2°C
4.91
3.79
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.27 kW
1.89 kW
COP Tj = +7°C
5.05
4.25
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.73 kW
0.86 kW
COP Tj = 12°C
5.21
4.37
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2722 kWh
3300 kWh
Calefacción
EN 14511-2
Baja temperatura
Media temperatura
Salida calefacción
2.58 kW
4.39 kW
Entrada EI
0.60 kW
1.53 kW
COP
4.30
2.84
EN 14511-4
cortando la trasferencia de calor de caudal medio
aprobado
Fallo completo de alimentación eléctrica
aprobado
Test de desescarche
aprobado
Starting and operating test
aprobado
Clima cálido
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
178 %
132 %
Prated
6.20 kW
6.00 kW
SCOP
4.66
3.49
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.16 kW
5.63 kW
COP Tj = +2°C
3.72
2.87
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.86 kW
3.62 kW
COP Tj = +7°C
4.43
3.34
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.71 kW
3.51 kW
COP Tj = 12°C
5.37
4.32
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
1777 kWh
2299 kWh
Clima frío
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
186 %
144 %
Prated
6.20 kW
6.00 kW
SCOP
4.85
3.81
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.64 kW
3.42 kW
COP Tj = -7°C
4.59
3.49
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.24 kW
2.10 kW
COP Tj = +2°C
5.27
4.12
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
1.44 kW
1.43 kW
COP Tj = +7°C
5.40
4.48
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
0.88 kW
1.21 kW
COP Tj = 12°C
4.91
4.87
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
3151 kWh
4011 kWh
Clima medio
EN 12102-1
Baja temperatura
Media temperatura
Potencia sonora de la unidad interior
44 dB(A)
44 dB(A)
EN 14825
Baja temperatura
Media temperatura
Pdesignh
6.20 kW
6.00 kW
ηs
180 %
142 %
Prated
6.20 kW
6.00 kW
SCOP
4.71
3.76
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.51 kW
5.06 kW
COP Tj = -7°C
4.10
3.06
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.33 kW
3.08 kW
COP Tj = +2°C
4.91
3.79
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.27 kW
1.89 kW
COP Tj = +7°C
5.05
4.25
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.73 kW
0.86 kW
COP Tj = 12°C
5.21
4.37
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.16 kW
5.63 kW
COP Tj = Tbiv
3.72
2.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.16 kW
5.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.87
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Calentador suplementario: tipo de energía de entrada
Electricidad
Electricidad
Calentador suplementario: PSUP
0.00 kW
0.00 kW
Consumo annual de energia QHE
2722 kWh
3300 kWh